Taťána Gazárková

Taťána Gazárková

Auto-generated profile, based on publicly available information

Taťána Gazárková

Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203, 500 05, Hradec Králové, Czech Republic

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2023 in Journal of Separation Science
Verified
Journal Article
Open access
KPKateřina Plachká
Kateřina Plachká
VPVeronika Pilařová
Veronika Pilařová
OHOndřej Horáček
Ondřej Horáček
TGTaťána Gazárková
Taťána Gazárková
HVHana Kočová Vlčková
Hana Kočová Vlčková
Lucie NovákováLucie Nováková
Lucie Nováková
Within this review, we thoroughly explored supercritical fluid chromatography (SFC) columns used across > 3000 papers published from the first study carried out under SFC conditions in 1962 to the end of 2022. We focused on the open tubular capillary, packed capillary, and packed columns, their chemistries, dimensions, and trends in used stationary phases with correlation to their specific interactions, advantages, drawbacks, used instrumentation, and application field. Since the 1990s, packed columns with liquid chromatography and SFC‐dedicated stationary phases for chiral and achiral separation are predominantly used. These stationary phases are based on silica support modified with a wide range of chemical moieties. Moreover, numerous unconventional stationary phases were evaluated, including porous graphitic carbon, titania, zirconia, alumina, liquid crystals, and ionic liquids. The applications of unconventional stationary phases are described in detail as they bring essential findings required for further development of the supercritical fluid chromatography technique.

28 September 2024 in Talanta
Verified
Journal Article
Open access
SNSphamandla Ntshangase
Sphamandla Ntshangase
SKShazia Khan
Shazia Khan
LBLouise Bezuidenhout
Louise Bezuidenhout
TGTaťána Gazárková
Taťána Gazárková
JKJakub Kaczynski
Jakub Kaczynski
RARuth Andrew
Ruth Andrew
Lipids contribute to atherosclerotic cardiovascular disease but their roles are not fully understood. Spatial lipid composition of atherosclerotic plaques was compared between species focusing on aortic plaques from New Zealand White rabbits and carotid plaques from humans (n = 3), using matrix-assisted laser desorption/ionization mass spectrometry imaging. Histologically discriminant lipids within plaque features (neointima and media in rabbits, and lipid-necrotic core and fibrous cap/tissue in humans) included sphingomyelins, phosphatidylcholines, and cholesteryl esters. There were 67 differential lipids between rabbit plaque features and 199 differential lipids in human, each with variable importance in projection score ≥1.0 and p < 0.05. The lipid profile of plaques in the rabbit model closely mimicked that of human plaques and two key pathways (impact value ≥ 0.1), sphingolipid and glycerophospholipid metabolism, were disrupted by atherosclerosis in both species. Thus, mass spectrometry imaging of spatial biomarkers offers valuable insights into atherosclerosis.

29 July 2024 in Analytical Chemistry
Verified
Journal Article
Open access
KPKateřina Plachká
Kateřina Plachká
VPVeronika Pilařová
Veronika Pilařová
TGTat’áNa Gazárková
Tat’áNa Gazárková
FSFrantisek Svec
Frantisek Svec
Jean-Christophe GarriguesJean-Christophe Garrigues
Jean-Christophe Garrigues
Lucie NovákováLucie Nováková
Lucie Nováková
The retention behavior in supercritical fluid chromatography and its stability over time are still unsatisfactorily explained phenomena despite many important contributions in recent years, especially focusing on linear solvation energy relationship modeling. We studied polar stationary phases with predominant -OH functionalities, i.e., silica, hybrid silica, and diol columns, and their retention behavior over time. We correlated molecular descriptors of analytes with their retention using three organic modifiers of the CO2-based mobile phase. The differences in retention behavior caused by using additives, namely, 10 mmol/L NH3 and 2% H2O in methanol, were described in correlation to analyte properties and compared with the CO2/methanol mobile phase. The structure of >100 molecules included in this study was optimized by semiempirical AM1 quantum mechanical calculations and subsequently described by 226 molecular descriptors including topological, constitutional, hybrid, electronic, and geometric descriptors. An artificial neural networks simulator with deep learning toolbox was trained on this extensive set of experimental data and subsequently used to determine key molecular descriptors affecting the retention by the highest extent. After comprehensive statistical analysis of the experimental data collected during one year of column use, the retention on different stationary phases was fundamentally described. The changes in the retention behavior during one year of column use were described and their explanation with a proposed interpretation of changes on the stationary phase surface was suggested. The effect of the regeneration procedure on the retention was also evaluated. This fundamental understanding of interactions responsible for retention in SFC can be used for the evidence-based selection of stationary phases suitable for the separation of particular analytes based on their specific physicochemical properties.

23 October 2024 in Analytica Chimica Acta
Verified
Journal Article
Closed access
TGTaťána Gazárková
Taťána Gazárková
HVHana Kočová Vlčková
Hana Kočová Vlčková
KPKateřina Plachká
Kateřina Plachká
KVKarla Vagnerová
Karla Vagnerová
DDDominika Dubecová
Dominika Dubecová
Lucie NovákováLucie Nováková
Lucie Nováková

28 August 2024 in Analytical Chemistry
Verified
Journal Article
Open access
MSMykyta R. Starovoit
Mykyta R. Starovoit
SJSiddharth Jadeja
Siddharth Jadeja
TGTaťána Gazárková
Taťána Gazárková
JLJuraj Lenčo
Juraj Lenčo
Elevating the column temperature is an effective strategy for improving the chromatographic separation of peptides. However, high temperatures induce artificial modifications that compromise the quality of the peptide analysis. Here, we present a novel high-temperature LC-MS method that retains the benefits of a high column temperature while significantly reducing peptide modification and degradation during reversed-phase liquid chromatography. Our approach leverages a short inline trap column maintained at a near-ambient temperature installed upstream of a separation column. The retentivity and dimensions of the trap column were optimized to shorten the residence time of peptides in the heated separation column without compromising the separation performance. This easy-to-implement approach increased peak capacity by 1.4-fold within a 110 min peptide mapping of trastuzumab and provided 10% more peptide identifications in exploratory LC-MS proteomic analyses compared with analyses conducted at 30 °C while maintaining the extent of modifications close to the background level. In the peptide mapping of biopharmaceuticals, where in-column modifications can falsely elevate the levels of some critical quality attributes, the method reduced temperature-related artifacts by 66% for N-terminal pyroGlu and 63% for oxidized Met compared to direct injection at 60 °C, thus improving reliability in quality control of protein drugs. Our findings represent a promising advancement in LC-MS methodology, providing researchers and industry professionals with a valuable tool for improving the chromatographic separation of peptides while significantly reducing the unwanted modifications.

21 January 2025 in Analytical Chemistry
Verified
Journal Article
Open access
KPKateřina Plachká
Kateřina Plachká
VPVeronika Pilařová
Veronika Pilařová
TGTat́áNa Gazárková
Tat́áNa Gazárková
FSFrantisek Svec
Frantisek Svec
Jean-Christophe GarriguesJean-Christophe Garrigues
Jean-Christophe Garrigues
Lucie NovákováLucie Nováková
Lucie Nováková
The retention behavior in supercritical fluid chromatography (SFC) remains a complex and poorly understood phenomenon despite the development of various models to explain retention mechanisms. This study aims to deepen the understanding of retention by investigating three distinct stationary phases: high-strength silica octadecyl (HSS C18 SB), charged surface hybrid pentafluorophenyl (CSH PFP), and porous graphitic carbon (PGC) as a nonsilica-based phase. Three mobile phase compositions, i.e., CO2/methanol, CO2/methanol +10 mmol/L NH3, and CO2/methanol +2% H2O, were investigated using an extensive set of analytes characterized by over 200 molecular descriptors. Artificial neural networks were employed to analyze the influence of these descriptors on retention behavior, revealing the most significant molecular features that increase or decrease retention on each column with the three different mobile phases. This complex evaluation of the large set of experimental data enabled to link specific analyte properties to retention interactions in SFC, including the interaction of analytes with partial positive charge with silanol groups on the HSS C18 SB column when using methanol + H2O as the organic modifier. The flexibility of the alkyl chain in the HSS C18 SB column is also affected by the composition of the organic modifier, which alters retention mechanisms, especially when NH3 is used as an additive. This highlights the critical role of the mobile phase composition in modulating the behavior of nonpolar stationary phases. Completely different interaction mechanisms were observed for the PGC column when comparing methanol with and without additives, suggesting possible modifications to the planar structure and surface polarizability of the PGC phase. Statistical evaluation of data collected over a year of column usage demonstrated distinct long-term retention stability trends. The HSS C18 SB column exhibited the greatest stability with methanol + H2O, whereas significant retention decreases were observed with methanol + NH3 modifier, particularly for CSH PFP and, unexpectedly, also for PGC. These findings provide crucial insights into the long-term retention behavior and aging of SFC columns, with practical implications for optimizing SFC conditions and improving column lifetime.