Kazuyuki Dei

Kazuyuki Dei

Auto-generated profile, based on publicly available information

Kazuyuki Dei

Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2017 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
KDKazuyuki Dei
Kazuyuki Dei
BBBrett Byram
Brett Byram
Recent studies reveal that both phase aberration and reverberation play a major role in degrading ultrasound image quality. We previously developed an algorithm for suppressing clutter, but we have not yet tested it in the context of aberrated wavefronts. In this paper, we evaluate our previously reported algorithm, called aperture domain model image reconstruction (ADMIRE), in the presence of phase aberration and in the presence of multipath scattering and phase aberration. We use simulations to investigate phase aberration corruption and correction in the presence of reverberation. As part of this paper, we observed that ADMIRE leads to suppressed levels of aberration. In order to accurately characterize aberrated signals of interest, we introduced an adaptive component to ADMIRE to account for aberration, referred to as adaptive ADMIRE. We then use ADMIRE, adaptive ADMIRE, and conventional filtering methods to characterize aberration profiles on in vivo liver data. These in vivo results suggest that adaptive ADMIRE could be used to better characterize a wider range of aberrated wavefronts. The aberration profiles' full-width at half-maximum of ADMIRE, adaptive ADMIRE, and postfiltered data with 0.4-mm -1 spatial cutoff frequency are 4.0 ± 0.28 mm, 2.8 ± 1.3 mm, and 2.8 ± 0.57 mm, respectively, while the average root-mean square values in the same order are 16 ± 5.4 ns, 20 ± 6.3 ns, and 19 ± 3.9 ns, respectively. Finally, because ADMIRE suppresses aberration, we perform a limited evaluation of image quality using simulations and in vivo data to determine how ADMIRE and adaptive ADMIRE perform with and without aberration correction.


25 May 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
CKChristopher Khan
Christopher Khan
KDKazuyuki Dei
Kazuyuki Dei
SSSiegfried Schlunk
Siegfried Schlunk
KOKathryn Ozgun
Kathryn Ozgun
BBBrett Byram
Brett Byram
Multipath and off-axis scattering are two of the primary mechanisms for ultrasound image degradation. To address their impact, we have proposed Aperture Domain Model Image REconstruction (ADMIRE). This algorithm utilizes a model-based approach in order to identify and suppress sources of acoustic clutter. The ability of ADMIRE to suppress clutter and improve image quality has been demonstrated in previous works, but its use for real-time imaging has been infeasible due to its significant computational requirements. However, in recent years, the use of graphics processing units (GPUs) for general-purpose computing has enabled the significant acceleration of compute-intensive algorithms. This is because many modern GPUs have thousands of computational cores that can be utilized to perform massively parallel processing. Therefore, in this work, we have developed a GPU-based implementation of ADMIRE. The implementation on a single GPU provides a speedup of two orders of magnitude when compared to a serial CPU implementation, and additional speedup is achieved when the computations are distributed across two GPUs. In addition, we demonstrate the feasibility of the GPU implementation to be used for real-time imaging by interfacing it with a Verasonics Vantage 128 ultrasound research system. Moreover, we show that other beamforming techniques, such as delay-and-sum (DAS) and short-lag spatial coherence (SLSC), can be computed and simultaneously displayed with ADMIRE. The frame rate depends upon various parameters, and this is exhibited in the multiple imaging cases that are presented. An open-source code repository containing CPU and GPU implementations of ADMIRE is also provided.

26 June 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
KDKazuyuki Dei
Kazuyuki Dei
SSSiegfried Schlunk
Siegfried Schlunk
BBBrett Byram
Brett Byram
Aperture domain model image reconstruction (ADMIRE) is a useful tool to mitigate ultrasound imaging artifacts caused by acoustic clutter. However, its lengthy run-time impairs its usefulness. To overcome this drawback, we evaluated the reduced model methods with otherwise similar performance to ADMIRE. We also assessed other approaches to speed up ADMIRE, including the use of different levels of short-time Fourier transform (STFT) window overlap and examining the degrees of freedom of the model fit. In this study, we conducted an analysis of the reduced models, including those using Gram-Schmidt orthonormalization (GSO), singular value decomposition (SVD), and independent component analysis (ICA). We evaluated these reduced models using the data from simulations, experimental phantoms, and in vivo liver scans. We then tested ADMIRE's performance using full, GSO, SVD, and ICA-fourth-order blind identification (ICA-FOBI) models. The results from simulations, experimental phantoms, and in vivo data indicate that a model reduced using the ICA-FOBI method is the most promising for accelerating ADMIRE implementation. In the in vivo liver data, the improvements in contrast relative to delay-and-sum (DAS) using a full model, GSO, SVD, and ICA-FOBI models are 6.29 ± 0.25 dB, 11.88 ± 0.90 dB, 9.01 ± 0.67 dB, and 6.36 ± 0.27 dB, respectively; whereas, the contrast-to-noise ratio (CNR) improvement values in the same order are 0.04 ± 0.06 dB, -1.70 ± 0.17 dB, -1.51 ± 0.19 dB, and 0.12 ± 0.07 dB, respectively. The implementation of ADMIRE using the reduced model methods can decrease ADMIRE's computational complexity over three orders of magnitude. The use of a 50% STFT window overlap reduces ADMIRE's serial run time by more than one order of magnitude without any remarkable loss of image quality, when compared to the use of a 90% window overlap used previously. Based on these findings, a combination of the ICA-FOBI model and the use of a 50% STFT window overlap makes the ADMIRE algorithm more computationally efficient.

25 February 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
SSSiegfried Schlunk
Siegfried Schlunk
KDKazuyuki Dei
Kazuyuki Dei
BBBrett Byram
Brett Byram
Clutter produced using bright acoustic sources can obscure weaker acoustic targets, degrading the quality of the image in scenarios with high dynamic ranges. Many adaptive beamformers seek to improve image quality by reducing these sidelobe artifacts, generating a boost in contrast ratio or contrast-to-noise ratio. However, some of these beamformers inadvertently introduce a dark region artifact in place of the strong clutter, a situation that occurs when both clutter and the underlying signal of interest are removed. We introduce the iterative aperture domain model image reconstruction (iADMIRE) method that is designed to reduce clutter while preserving the underlying signal. We compare the contrast ratio dynamic range (CRDR) of iADMIRE to several other adaptive beamformers plus delay-and-sum (DAS) to quantify the accuracy and reliability of the reported measured contrast for each beamformer over a wide range of contrast levels. We also compare all beamformers in the presence of bright targets ranging from 40 to 120 dB to observe the presence of sidelobes. In cases with no added reverberation clutter, iADMIRE had a CRDR of 75.6 dB when compared with the next best method DAS with 60.8 dB. iADMIRE also demonstrated the best performance for levels of reverberation clutter up to 0-dB signal-to-clutter ratio. Finally, iADMIRE restored underlying speckle signal in dark artifact regions while suppressing sidelobes in bright target cases up to 100 dB.

26 April 2018 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
KDKazuyuki Dei
Kazuyuki Dei
JTJaime Tierney
Jaime Tierney
BBBrett Byram
Brett Byram
We are interested in examining how our model-based beamforming algorithm, referred to as aperture-domain model image reconstruction (ADMIRE), performs on plane wave sequences in conjunction with synthetic aperture beamforming. We also aim to identify the impact of ADMIRE applied before and after synthetic focusing. We employed simulated phantoms using Field II and tissue-mimicking phantoms to evaluate ADMIRE as applied to synthetic sequencing. We generated plane wave images with and without synthetic aperture focusing (SAF) and measured contrast and contrast-to-noise ratio (CNR). For simulated cyst images formed from single plane waves, the contrast for delay-and-sum (DAS) and ADMIRE are 15.64 and 28.34 dB, respectively, whereas the CNR are 1.76 and 3.90 dB, respectively. We also applied ADMIRE to simulated resolution phantoms having a point target at 3 cm depth on-axis. We simulated the point spread functions from data obtained from 1 plane wave and 75 steered plane waves, along with linear scans with 3 and 4 cm- focal depths. We then compared the outcome of applying ADMIRE before and after SAF using 3 and 11 steered plane waves. Finally, we applied this to an in vivo carotid artery. Based on the findings in this study, ADMIRE can be adapted to full field insonification sequences to improve image quality in plane wave imaging. Additionally, we investigated how robustly ADMIRE performs in the presence of random noise. We then address identified limitations using a conventional envelope detection method with decluttered signals.