26 July 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Singular value decomposition (SVD) is a valuable factorization technique used in clutter rejection filtering for power Doppler imaging. Conventionally, SVD is applied to a Casorati matrix of radio frequency data, which enables filtering based on spatial or temporal characteristics. In this article, we propose a clutter filtering method that uses a higher order SVD (HOSVD) applied to a tensor of aperture data, e.g., delayed channel data. We discuss temporal, spatial, and aperture domain features that can be leveraged in filtering and demonstrate that this multidimensional approach improves sensitivity toward blood flow. Further, we show that HOSVD remains more robust to short ensemble lengths than conventional SVD filtering. Validation of this technique is shown using Field II simulations and in vivo data.
14 November 2019 in IEEE Transactions on Medical Imaging
Acoustic clutter is a primary source of image degradation in ultrasound imaging. In the context of flow imaging, tissue and acoustic clutter signals are often much larger in magnitude than the blood signal, which limits the sensitivity of conventional power Doppler in SNR-limited environments. This has motivated the development of coherence-based beamformers, including Coherent Flow Power Doppler (CFPD), which have demonstrated efficacy in mitigating sources of diffuse clutter. However, CFPD uses a measure of normalized coherence, which incurs a non-linear relationship between image intensity and the magnitude of the blood echo. As a result, CFPD is not a robust approach to study gradation of blood signal energy, which depicts the fractional moving blood volume. We propose the application of mutual intensity, rather than normalized coherence, to retain the clutter suppression capability inherent in coherence beamforming, while preserving the underlying signal energy. Feasibility of this approach was shown via Field II simulations, phantoms, and in vivo human liver data. In addition, we derive an adaptive statistical threshold for the suppression of residual noise signals. Overall, this beamformer design shows promise as an alternative technique to depict flow volume gradation in cluttered imaging environments.
25 May 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Multipath and off-axis scattering are two of the primary mechanisms for ultrasound image degradation. To address their impact, we have proposed Aperture Domain Model Image REconstruction (ADMIRE). This algorithm utilizes a model-based approach in order to identify and suppress sources of acoustic clutter. The ability of ADMIRE to suppress clutter and improve image quality has been demonstrated in previous works, but its use for real-time imaging has been infeasible due to its significant computational requirements. However, in recent years, the use of graphics processing units (GPUs) for general-purpose computing has enabled the significant acceleration of compute-intensive algorithms. This is because many modern GPUs have thousands of computational cores that can be utilized to perform massively parallel processing. Therefore, in this work, we have developed a GPU-based implementation of ADMIRE. The implementation on a single GPU provides a speedup of two orders of magnitude when compared to a serial CPU implementation, and additional speedup is achieved when the computations are distributed across two GPUs. In addition, we demonstrate the feasibility of the GPU implementation to be used for real-time imaging by interfacing it with a Verasonics Vantage 128 ultrasound research system. Moreover, we show that other beamforming techniques, such as delay-and-sum (DAS) and short-lag spatial coherence (SLSC), can be computed and simultaneously displayed with ADMIRE. The frame rate depends upon various parameters, and this is exhibited in the multiple imaging cases that are presented. An open-source code repository containing CPU and GPU implementations of ADMIRE is also provided.
30 March 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Thermal noise and acoustic clutter signals degrade ultrasonic image quality and contribute to unreliable clinical assessment. When both noise and clutter are prevalent, it is difficult to determine which one is a more significant contributor to image degradation because there is no way to separately measure their contributions in vivo . Efforts to improve image quality often rely on an understanding of the type of image degradation at play. To address this, we derived and validated a method to quantify the individual contributions of thermal noise and acoustic clutter to image degradation by leveraging spatial and temporal coherence characteristics. Using Field II simulations, we validated the assumptions of our method, explored strategies for robust implementation, and investigated its accuracy and dynamic range. We further proposed a novel robust approach for estimating spatial lag-one coherence. Using this robust approach, we determined that our method can estimate the signal-to-thermal noise ratio (SNR) and signal-to-clutter ratio (SCR) with high accuracy between SNR levels of −30 to 40 dB and SCR levels of −20 to 15 dB. We further explored imaging parameter requirements with our Field II simulations and determined that SNR and SCR can be estimated accurately with as few as two frames and sixteen channels. Finally, we demonstrate in vivo feasibility in brain imaging and liver imaging, showing that it is possible to overcome the constraints of in vivo motion using high-frame rate M-Mode imaging.