School of Electric Power, South China University of Technology, Guangzhou 510630, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in IEEE Access
Verified
Journal Article
Open access
YXYue Xie
Yue Xie
YZYifeng Zhao
Yifeng Zhao
SBShuzhen Bao
Shuzhen Bao
PWPengyu Wang
Pengyu Wang
JHJiasheng Huang
Jiasheng Huang
LLLicheng Li
Licheng Li
Further research on retired cable rejuvenation via heat treatment was investigated in this paper. Three retired cables with service year of 7, 15 and 30 years were used and annealed at different temperatures following two different heat treatment methods. In the first test, two short cables with a length of 5 m were prepared and cut into five equal segments. Four segments of each cable were annealed at 90, 95, 100, and 105 ℃ to simulate the cable operation. Then, the cross-linked polyethylene (XLPE) from the cable insulation was peeled, and the peels from the inner, middle and outer positions were selected and subjected to the differential scanning calorimetry (DSC), DC conduction current, and dielectric breakdown strength measurements. The thermal and electrical performance of these samples were analyzed, and the optimum annealing temperature was determined. In the second test, three identical long cables were connected to a transformer, joints, and terminals to build two experimental circuits. The cables were annealed at the optimum temperature determined in the first test. The same measurements were performed on XLPE samples taken from the same positions as those in the first test. The results showed that the short cables exhibited the best thermal and electrical performance when annealed at 95 ℃. The three long cables annealed at 95 ℃ verified that the thermal and electrical properties of the cable insulation were significantly improved. The results of the two different annealing methods, which closely represent the actual cable operations, verified the feasibility that old cables without overheating history could be rejuvenated via heat treatment.

6 January 2020 in IEEE Access
Verified
Journal Article
Open access
YXYue Xie
Yue Xie
YZYifeng Zhao
Yifeng Zhao
SBShuzhen Bao
Shuzhen Bao
PWPengyu Wang
Pengyu Wang
JHJiasheng Huang
Jiasheng Huang
LLLicheng Li
Licheng Li
In this work, heat treatment was performed on three retired 110 kV AC cables with service years of 0, 15 and 30, and the effects on the thermal and electrical performance of the cable insulation were investigated. First, each cable with a length approximately of 5 m was prepared and cut into five equal segments. Four segments of each cable were annealed at a temperature of 90, 95, 100, or 105 °C by building a small circuit to simulate cable operation. Then, a section at the middle of each segment was cut out, and the insulation layer was peeled away. The peeled-off layers from the inner, middle and outer positions were selected as the test samples. Subsequently, Fourier transform infrared spectrometry (FTIR), and differential scanning calorimetry (DSC) were performed, and the DC conduction current and dielectric breakdown strength were measured. The best thermal properties of the highest melting point, crystallinity, and smallest melting range were found when the cables were annealed at 100, 105, and 105 °C for the inner, middle, and outer positions, respectively. The highest dielectric breakdown strength and lowest electrical conductivity were found at temperatures of 95 or 100 °C for the inner and middle positions, respectively, and at 105 °C for the outer position. The FTIR results showed that thermal annealing for hundreds of hours did not adversely affect the molecular chains. It is found that this type of heat treatment could be a feasible method to rejuvenate retired cables, and a conservative temperature of 95 °C is regarded as the optimum annealing temperature.