Mohideen Salihu Farook

Mohideen Salihu Farook

Auto-generated profile, based on publicly available information

Mohideen Salihu Farook

Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2016 in Desalination and Water Treatment
Verified
Journal Article
Open access
KAKh. Asaduzzaman
Kh. Asaduzzaman
FMF. Mannan
F. Mannan
Mayeen Uddin KhandakerMayeen Uddin Khandaker
Mayeen Uddin Khandaker
MFM.S. Farook
M.S. Farook
AEA. Elkezza
A. Elkezza
SSS. Sharma
S. Sharma
This work presents radiological data on most commonly sold bottled water brands in the urban areas of Bangladesh. A significant fragment of the population use bottled water as their source of daily water intake. It is known from the literature that some varieties of bottled waters contain natural radionuclides in higher concentration than the traditional municipal tap water. In this study, concentrations of naturally occurring radioactive materials, particularly 226Ra, 228Ra, and 40K, and its annual effective dose with its stochastic effects were determined in available brands of bottled mineral water manufactured in Bangladesh. The measurement was performed by gamma-ray spectroscopy using a hyper-pure germanium detector. The activity concentration of the radiologically important nuclides 226Ra and 228Ra were found within the permissible limits of 1 and 0.1 Bq l−1, respectively, recommended by World Health Organization (WHO) in almost all samples. The annual effective doses caused by natural radioactivity of 228Ra for the infants (0–1 year) and adolescent (12–17 year) groups exceeded the recommended WHO guideline level of 0.1 mSv y−1 for drinking water in most of the cases. Particularly for those age groups, the estimated doses are extremely high. In general, the carcinogenic risk due to natural radioactive doses for all bottled water samples were found below the acceptable limit of 10−3.

1 January 2022 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
OMOkba Mahmoud
Okba Mahmoud
NANashwan Abdullah Al-Afifi
Nashwan Abdullah Al-Afifi
MFMohideen Salihu Farook
Mohideen Salihu Farook
MIMaysara Adnan Ibrahim
Maysara Adnan Ibrahim
SSSaaid Al Shehadat
Saaid Al Shehadat
MAMohammed Alsaegh
Mohammed Alsaegh
Objectives. Particle size and shape can influence the properties of materials. However, to improve the physicochemical and biological properties of mineral trioxide aggregate (MTA), silicate‐based hydraulic cements were introduced. This study aimed to evaluate and compare the major constituents and crystalline structures along with the surface morphology of different types of calcium silicate‐based cement (CSC). Materials and Methods. Six different types of CSC (white Portland cement, white ProRoot MTA, white MTA Angelus, Biodentine, and Endosequence, both putty and paste) were used in this study. Five samples of each material were analyzed in both uncured and cured cement using scanning electron microscopy/energy‐dispersive X‐ray (SEM/EDX), X‐ray diffraction (XRD), and Fourier transform‐infrared spectroscopy (FTIR). Results. SEM analysis showed that the surfaces of all materials consisted of particle sizes ranging from 0.194 μm to approximately 51.82 μm. The basic elements found in both uncured and cured cement of all tested materials using EDX were carbon, calcium, silicon, and oxygen. A difference was observed in the presence or absence of magnesium, aluminum, bismuth, zirconium, and tantalum. XRD showed that all tested materials were composed mainly of tricalcium silicate and dicalcium silicate, which are the main components of Portland cement. FTIR analysis showed aromatic rings, phosphine PH, alkyl halides, and alcohol O‐H groups in all tested materials but at different wavenumbers. Conclusions. The different types of CSCs tested in this study were primarily modified types of Portland cement with the addition of radiopacifiers. ProRoot MTA and MTA Angelus contained bismuth oxide, Biodentine contains zirconium oxide, whereas Endosequence root repair materials (both putty and paste) contained zirconium oxide and tantalum oxide. Endosequence root repair materials showed smaller particle sizes than the other groups. White PC had the most irregular and large particle sizes. CSC had a smaller particle size, except for MTA Angelus. Clinical Relevance. The composition of CSC has a direct influence on the properties of these cements, which may affect the clinical outcome of the treatment.

7 April 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
HAHany Mohamed Aly Ahmed
Hany Mohamed Aly Ahmed
MFMohideen Salihu Farook
Mohideen Salihu Farook
Mandibular first premolar teeth show a wide range of root and canal anatomical variations including accessory roots, deep root proximal grooves and multiple canals. This study provides qualitative and quantitative morphological analysis of a rare four-rooted mandibular first premolar scanned using micro-CT. In addition, it provides clinical implications through endodontic access cavity preparation and negotiation of canals under dental operating microscope (DOM) to assess the difficulty for locating the canals. An extracted four-rooted mandibular first premolar tooth sample was subjected to 2D radiographic imaging in two views and micro-computed tomography (micro-CT) scanning with a resolution of 25 μm. Subsequently, 3D- reconstruction of the tooth sample was performed using Mimics software (Materialise, Leuven, Belgium). 3D (volume and surface area) and 2D measurements (distances between orifices, area, perimeter, maximum and minimum diameter, roundness, aspect ratio and form factor) were obtained. In addition, endodontic access was prepared, and the canals were explored under the DOM. Location of the canals were confirmed by periapical radiographs with the aid of hand files. The 2D imaging showed the presence of four canals. Micro-CT analysis showed a complex canal anatomy which was classified using Ahmed et al. coding system as 444 MB1–2–1–2 DB2-1-2-1-3-2-3 1(ML1 DL1). Quantitative analysis showed that the MB root had the highest canal volume and surface area compared to other canals. The 2D measurements showed wide variations among canals, which reflects the complexity of the canals in terms of size and geometry. The MB and DB canals tend to have more aspect ratio values (more oval/flattened) than other canals. After access cavity preparation and exploration, six root canals were identified [mesio-buccal one (MB1), mesio-buccal two (MB2), disto-buccal (DB), mesio-lingual (ML), disto-lingual (DL) and lingual disto-buccal (LDB)]. The canals in the MB root showed two locations of splitting. Mandibular first premolars may have complex variations in the number of roots and canal configurations. The different anatomical presentations demonstrated in the 2D and 3D measurements of the six canals presented in this report signifies the anatomical variabilities, which could complicate the detection and negotiation of canals during root canal treatment. Ahmed et al. coding system is useful in classifying teeth with complex root and canal anatomy.

1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
MFMohideen S. Farook
Mohideen S. Farook
OMOkba Mahmoud
Okba Mahmoud
MIMaysara Adnan Ibrahim
Maysara Adnan Ibrahim
MBMarwah Berkathullah
Marwah Berkathullah
Objectives. To evaluate the in vitro effectiveness of desensitizing agents in reducing dentine permeability. Methods. The efficacy of desensitizing agents in reducing dentine permeability by occluding dentine tubules was evaluated using a fluid filtration device that conducts at 100 cmH2O (1.4 psi) pressure, and SEM/EDX analyses were evaluated and compared. Forty‐two dentine discs (n = 42) of 1 ± 0.2 mm width were obtained from caries‐free permanent human molars. Thirty dentine discs (n = 30) were randomly divided into 3 groups (n = 10): Group 1: 2.7% wt. monopotassium‐monohydrogen oxalate (Mp‐Mh oxalate), Group 2: RMGI XT VAR, and Group 3: LIQ SiO2. Dentine permeability was measured following treatment application after 10 minutes, storage in artificial saliva after 10 minutes and 7 days, and citric acid challenge for 3 minutes. Data were analysed with a repeated measures ANOVA test. Dentine discs (n = 12) were used for SEM/EDX analyses to acquire data on morphological changes on dentine surface and its mineral content after different stages of treatment. Results. Desensitizing agents’ application on the demineralized dentine discs exhibited significant reduction of permeability compared to its maximum acid permeability values. Mp‐Mh oxalate showed a significant reduction in dentine permeability (p < 0.05) when compared to RMGI XT VAR and LIQ SiO2. On SEM/EDX analysis, all the agents formed mineral precipitates that occluded the dentine tubules. Conclusions. 2.7% wt. monopotassium‐monohydrogen oxalate was significantly effective in reducing dentine permeability compared to RMGI XT VAR and LIQ SiO2.

26 May 2026 in European Journal of Dental Education
Verified
Journal Article
Closed access
OMOkba Mahmoud
Okba Mahmoud
MFMohideen Salihu Farook
Mohideen Salihu Farook
BEBassem Mohamed Eid
Bassem Mohamed Eid
SSSaaid Al Shehadat
Saaid Al Shehadat
MEMohamed Ahmed Elsayed
Mohamed Ahmed Elsayed
HAHany Mohamed Aly Ahmed
Hany Mohamed Aly Ahmed

3 July 2026 in European Journal of Dental Education
Verified
Journal Article
Closed access
MEMohamed Ahmed Elsayed
Mohamed Ahmed Elsayed
FHFatma Pertek Hatipoğlu
Fatma Pertek Hatipoğlu
NTNessrin Taha
Nessrin Taha
MFMohideen Salihu Farook
Mohideen Salihu Farook
SSSaaid Al Shehadat
Saaid Al Shehadat
ÖHÖmer Hatipoğlu
Ömer Hatipoğlu