Paolo Orlando

Paolo Orlando

Auto-generated profile, based on publicly available information

Paolo Orlando

Department of Health Sciences, University of Genoa, Genoa, Italy

Research Focus & Metrics

Academic Career Length

47Years (1980-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2006 in Infection Control & Hospital Epidemiology
Verified
Journal Article
Closed access
PDF file
FPF. Perdelli
F. Perdelli
MCMaria Luisa Cristina
Maria Luisa Cristina
Marina SartiniMarina Sartini
Marina Sartini
ASAnna Maria Spagnolo
Anna Maria Spagnolo
MDM. Dallera
M. Dallera
POP. Orlando
P. Orlando
Objectives.: To assess the degree of fungal contamination in hospital environments and to evaluate the ability of air conditioning systems to reduce such contamination.Methods.: We monitored airborne microbial concentrations in various environments in 10 hospitals equipped with air conditioning. Sampling was performed with a portable Surface Air System impactor with replicate organism detection and counting plates containing a fungus-selective medium. The total fungal concentration was determined 72-120 hours after sampling. The genera most involved in infection were identified by macroscopic and microscopic observation.Results.: The mean concentration of airborne fungi in the set of environments examined was 19 ± 19 colony-forming units (cfu) per cubic meter. Analysis of the fungal concentration in the different types of environments revealed different levels of contamination: the lowest mean values (12 ± 14 cfu/m3) were recorded in operating theaters, and the highest (45 ± 37 cfu/m3) were recorded in kitchens. Analyses revealed statistically significant differences between median values for the various environments. The fungal genus most commonly encountered was Penicillium, which, in kitchens, displayed the highest mean airborne concentration (8 ± 2.4 cfu/m3). The percentage (35%) of Aspergillus documented in the wards was higher than that in any of the other environments monitored.Conclusions.: The fungal concentrations recorded in the present study are comparable to those recorded in other studies conducted in hospital environments and are considerably lower than those seen in other indoor environments that are not air conditioned. These findings demonstrate the effectiveness of air-handling systems in reducing fungal contamination.

21 December 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MCMaria Luisa Cristina
Maria Luisa Cristina
ASAnna Maria Spagnolo
Anna Maria Spagnolo
Marina SartiniMarina Sartini
Marina Sartini
DPDonatella Panatto
Donatella Panatto
RGRoberto Gasparini
Roberto Gasparini
FPFernanda Perdelli
Fernanda Perdelli
Several studies have proposed that the microbiological quality of the air in operating theatres be indirectly evaluated by means of particle counting, a technique derived from industrial clean-room technology standards, using airborne particle concentration as an index of microbial contamination. However, the relationship between particle counting and microbiological sampling has rarely been evaluated and demonstrated in operating theatres. The aim of the present study was to determine whether particle counting could predict microbiological contamination of the air in an operating theatre during 95 surgical arthroplasty procedures. This investigation was carried out over a period of three months in 2010 in an orthopedic operating theatre devoted exclusively to prosthetic surgery. During each procedure, the bacterial contamination of the air was determined by means of active sampling; at the same time, airborne particulate contamination was assessed throughout the entire procedure. On considering the total number of surgical operations, the mean value of the total bacterial load in the center of the operating theatre proved to be 35 CFU/m3; the mean particle count was 4,194,569 no./m3 for particles of diameter ≥0.5 µm and 13,519 no./m3 for particles of diameter ≥5 µm. No significant differences emerged between the median values of the airborne microbial load recorded during the two types of procedure monitored. Particulates with a diameter of ≥0.5 µm were detected in statistically higher concentrations (p<0.001) during knee-replacement procedures. By contrast, particulates with a diameter of ≥5 µm displayed a statistically higher concentration during hip-replacement procedures (p<0.05). The results did not reveal any statistically significant correlation between microbial loads and particle counts for either of the particle diameters considered (≥0.5 µm and ≥5 µm). Consequently, microbiological monitoring remains the most suitable method of evaluating the quality of air in operating theatres.

1 February 2014 in Infection Control & Hospital Epidemiology
Verified
Journal Article
Closed access
PDF file
MCMaria Luisa Cristina
Maria Luisa Cristina
ASAnna Maria Spagnolo
Anna Maria Spagnolo
Beatrice CasiniBeatrice Casini
Beatrice Casini
ABAngelo Baggiani
Angelo Baggiani
PGPietro Del Giudice
Pietro Del Giudice
POPaolo Orlando
Paolo Orlando
Objective.: Our aim was to evaluate the impact of aerators on water microbiological contamination in at-risk hospital departments, with a view to quantifying the possible risk of patient exposure to waterborne microorganisms.Design.: We analyzed the microbiological and chemical-physical characteristics of hot and cold water in some critical hospital departments.Setting.: Two hospitals in northern Italy.Methods.: We took 304 water samples over a 1-year period, at 3-month intervals, from taps used by healthcare personnel for handwashing, surgical washing, and the washing of medical equipment. We analyzed heterotrophic plate counts (HPCs) at 36°C and 22°C, nonfastidious gram-negative bacteria (GNB-NE), andLegionella pneumophila.Results.: The percentages of positivity and mean values of HPCs at 22°C, HPCs at 36°C, and GNB-NE loads were significantly higher at outlet points than in the plumbing system. In particular, GNB-NE positivity was higher at outlet points than in the plumbing system in both the cold water (31.58% vs 6.58% of samples were positive) and hot water (21.05% vs 3.95%) supplies. Our results also revealed contamination byL. pneumophilaboth in the plumbing system and at outlet points, with percentages of positive samples varying according to the serogroup examined (serogroups 1 and 2-14). The mean concentrations displayed statistically significant (P< .001) differences between the outlet points (27,382.89 ± 42,245.33 colony-forming units [cfu]/L) and the plumbing system (19,461.84 ± 29,982.11 cfu/L).Conclusions.: These results reveal a high level of contamination of aerators by various species of gram-negative opportunists that are potentially very dangerous for immunocompromised patients and, therefore, the need to improve the management of these devices.

1 January 2014 in Reviews and Research in Medical Microbiology
Verified
Journal Article
Closed access
ASAnna Maria Spagnolo
Anna Maria Spagnolo
POPaolo Orlando
Paolo Orlando
DPDonatella Panatto
Donatella Panatto
FPFernanda Perdelli
Fernanda Perdelli
MCMaria Luisa Cristina
Maria Luisa Cristina
The emergence and dissemination of carbapenem resistance among Enterobacteriaceae, especially Klebsiella pneumoniae, constitute a serious threat to public health, since carbapenems are the agents of last resort in the treatment of life-threatening infections caused by drug-resistant Enterobacteriaceae. In K. pneumoniae, carbapenem resistance was first reported a decade ago and has subsequently emerged in several countries. One particular group of transmissible plasmid-encoded carbapenemase enzymes, designated K. pneumoniae carbapenemase (KPC), confers carbapenem resistance to K. pneumoniae strains and is rapidly spreading worldwide. In addition to KPC-producing K. pneumoniae, several different metallo-β-lactamase-producing strains have been identified. These include New Delhi metallo-β-lactamase, Verona integron-encoded metallo-β-lactamase and imipenemase metallo-β-lactamase. Finally, class D carbapenemases, including oxacillin-type carbapenemases, also occur in K. pneumoniae. Carbapenem-resistant K. pneumoniae (CRKP) can cause several types of healthcare-associated infections, including pneumonia, bloodstream infections, wound or surgical site infections, urinary tract infections and meningitis, and is associated with high mortality rates. Multifactorial intervention, including hand hygiene, contact precautions, patient and staff cohorting, minimizing invasive device use, promoting antimicrobial stewardship, screening, active surveillance testing and chlorhexidine bathing, may be an effective strategy for reducing the nosocomial transmission of CRKP. Moreover, the rapid notification of clinical infection whenever CRKP are identified from clinical specimens allows the timely implementation of control measures.

1 April 2013 in Public Health
Verified
Journal Article
Closed access
MCMaria Luisa Cristina
Maria Luisa Cristina
ASAnna Maria Spagnolo
Anna Maria Spagnolo
NCN. Cenderello
N. Cenderello
PFP. Fabbri
P. Fabbri
Marina SartiniMarina Sartini
Marina Sartini
POP. Orlando
P. Orlando

1 November 2011 in American Journal of Infection Control
Verified
Journal Article
Closed access
MCMaria Luisa Cristina
Maria Luisa Cristina
ASAnna Maria Spagnolo
Anna Maria Spagnolo
GOGianluca Ottria
Gianluca Ottria
MSMarina Sartini
Marina Sartini
POPaolo Orlando
Paolo Orlando
GGGalliera Hospital Group
Galliera Hospital Group