Abdullah S. Bdaiwi

Abdullah S. Bdaiwi

Auto-generated profile, based on publicly available information

Abdullah S. Bdaiwi

Center for Pulmonary Imaging Research, Division of Pulmonary Medicine Cincinnati Children's Hospital Medical Center Cincinnati Ohio USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
ABAbdullah S. Bdaiwi
Abdullah S. Bdaiwi
MWMatthew M. Willmering
Matthew M. Willmering
HWHui Wang
Hui Wang
ZCZackary I. Cleveland
Zackary I. Cleveland
Purpose: To enable efficient hyperpolarized 129Xe diffusion imaging using 2D and 3D (Fermat Looped, ORthogonally Encoded Trajectories, FLORET) spiral sequences and demonstrate that 129Xe ADCs obtained using these sequences are comparable to those obtained using a conventional, 2D gradient‐recalled echo (GRE) sequence.Theory and Methods: Diffusion‐weighted 129Xe MRI (b‐values = 0, 7.5, 15 s/cm2) was performed in four healthy volunteers and one subject with lymphangioleiomyomatosis using slice‐selective 2D‐GRE (scan time = 15 s), slice‐selective 2D‐Spiral (4 s), and 3D‐FLORET (16 s) sequences. Experimental SNRs from b‐value = 0 images () and mean ADC values were compared across sequences. In two healthy subjects, a second b = 0 image was acquired using the 2D‐Spiral sequence to map flip angle and correct RF‐induced, hyperpolarized signal decay at the voxel level, thus improving regional ADC estimates.Results: Diffusion‐weighted images from spiral sequences displayed image quality comparable to 2D‐GRE and produced sufficient (16.8 ± 3.8 for 2D‐GRE, 21.2 ± 3.5 for 2D‐Spiral, 20.4 ± 3.5 for FLORET) to accurately calculate ADC. Whole‐lung means and SDs of ADC obtained via spiral were not significantly different (P > 0.54) from those obtained via 2D‐GRE. Finally, 2D‐Spiral images were corrected for signal decay, which resulted in a whole‐lung mean ADC decrease of ˜15%, relative to uncorrected images.Conclusions: Relative to GRE, efficient spiral sequences allow 129Xe diffusion images to be acquired with isotropic lung coverage (3D), higher (2D and 3D), and three‐fold faster (2D) within a single breath‐hold. In turn, shortened breath‐holds enable flip‐angle mapping, and thus, allow RF‐induced signal decay to be corrected, increasing ADC accuracy.

2 November 2021 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
ABAbdullah S. Bdaiwi
Abdullah S. Bdaiwi
PNPeter Niedbalski
Peter Niedbalski
MHM. Hossain
M. Hossain
MWMatthew M. Willmering
Matthew M. Willmering
LWLaura L. Walkup
Laura L. Walkup
ZCZackary I. Cleveland
Zackary I. Cleveland

31 October 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
ABAbdullah S. Bdaiwi
Abdullah S. Bdaiwi
MWMatthew M. Willmering
Matthew M. Willmering
JPJoseph W. Plummer
Joseph W. Plummer
RHRiaz Hussain
Riaz Hussain
DRDavid J. Roach
David J. Roach
ZCZackary I. Cleveland
Zackary I. Cleveland
Purpose: Hyperpolarized 129Xe MRI presents opportunities to assess regional pulmonary microstructure and function. Ongoing advancements in hardware, sequences, and image processing have helped it become increasingly adopted for both research and clinical use. As the number of applications and users increase, standardization becomes crucial. To that end, this study developed an executable, open‐source 129Xe image processing pipeline (XIPline) to provide a user‐friendly, graphical user interface‐based analysis pipeline to analyze and visualize 129Xe MR data, including scanner calibration, ventilation, diffusion‐weighted, and gas exchange images.Methods: The customizable XIPline is designed in MATLAB to analyze data from all three major scanner platforms. Calibration data is processed to calculate optimal flip angle and determine129Xe frequency offset. Data processing includes loading, reconstructing, registering, segmenting, and post‐processing images. Ventilation analysis incorporates three common algorithms to calculate ventilation defect percentage and novel techniques to assess defect distribution and ventilation texture. Diffusion analysis features ADC mapping, modified linear binning to account for ADC age‐dependence, and common diffusion morphometry methods. Gas exchange processing uses a generalized linear binning for data acquired using 1‐point Dixon imaging.Results: The XIPline workflow is demonstrated using analysis from representative calibration, ventilation, diffusion, and gas exchange data.Conclusion: The application will reduce redundant effort when implementing new techniques across research sites by providing an open‐source framework for developers. In its current form, it offers a robust and adaptable platform for 129Xe MRI analysis to ensure methodological consistency, transparency, and support for collaborative research across multiple sites and MRI manufacturers.

4 February 2023 in Journal of Cystic Fibrosis
Verified
Journal Article
Closed access
MWMichael E. West
Michael E. West
DSDavid R. Spielberg
David R. Spielberg
DRDavid J. Roach
David J. Roach
MWMatthew M. Willmering
Matthew M. Willmering
ABAbdullah S. Bdaiwi
Abdullah S. Bdaiwi
JWJason C. Woods
Jason C. Woods

17 January 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
FKFilip Klimeš
Filip Klimeš
JPJoseph W. Plummer
Joseph W. Plummer
MWMatthew M. Willmering
Matthew M. Willmering
AMAlexander M. Matheson
Alexander M. Matheson
ABAbdullah S. Bdaiwi
Abdullah S. Bdaiwi
JVJens Vogel-Claussen
Jens Vogel-Claussen
Purpose: Pulmonary MRI faces challenges due to low proton density, rapid transverse magnetization decay, and cardiac and respiratory motion. The fermat‐looped orthogonally encoded trajectories (FLORET) sequence addresses these issues with high sampling efficiency, strong signal, and motion robustness, but has not yet been applied to phase‐resolved functional lung (PREFUL) MRI—a contrast‐free method for assessing pulmonary ventilation during free breathing. This study aims to develop a reconstruction pipeline for FLORET UTE, enhancing spatial resolution for three‐dimensional (3D) PREFUL ventilation analysis.Methods: The FLORET sequence was used to continuously acquire data over 7 ± 2 min in 36 participants, including healthy subjects (N = 7) and patients with various pulmonary conditions (N = 29). Data were reconstructed into respiratory images using motion‐compensated low‐rank reconstruction, and a 3D PREFUL algorithm was adapted to quantify static and dynamic ventilation surrogates. Image sharpness and signal‐to‐noise ratio were evaluated across different motion states. PREFUL ventilation metrics were compared with static 129Xe ventilation MRI.Results: Optimal image sharpness and accurate ventilation dynamics were achieved using 24 respiratory bins, leading to their use in the study. A strong correlation was found between 3D PREFUL FLORET UTE ventilation defect percentages (VDPs) and 129Xe VDPs (r ≥ 0.61, p < 0.0001), although PREFUL FLORET static VDPs were significantly higher (mean bias = −10.1%, p < 0.0001). In diseased patients, dynamic ventilation parameters showed greater heterogeneity and better alignment with 129Xe VDPs.Conclusion: The proposed reconstruction pipeline for FLORET UTE MRI offers improved spatial resolution and strong correlation with 129Xe MRI, enabling dynamic ventilation quantification that may reveal airflow abnormalities in lung disease.

11 June 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
JPJoseph W. Plummer
Joseph W. Plummer
RHRiaz Hussain
Riaz Hussain
ABAbdullah S. Bdaiwi
Abdullah S. Bdaiwi
SSStephanie A. Soderlund
Stephanie A. Soderlund
XHXavier Hoyos
Xavier Hoyos
LWLaura L. Walkup
Laura L. Walkup
Purpose: Hyperpolarized 129Xe MRI benefits from non‐Cartesian acquisitions that sample k‐space efficiently and rapidly. However, their reconstructions are complex and burdened by decay processes unique to hyperpolarized gas. Currently used gridded reconstructions are prone to artifacts caused by magnetization decay and are ill‐suited for undersampling. We present a compressed sensing (CS) reconstruction approach that incorporates magnetization decay in the forward model, thereby producing images with increased sharpness and contrast, even in undersampled data.Methods: Radio‐frequency, T1, and decay processes were incorporated into the forward model and solved using iterative methods including CS. The decay‐modeled reconstruction was validated in simulations and then tested in 2D/3D‐spiral ventilation and 3D‐radial gas‐exchange MRI. Quantitative metrics including apparent‐SNR and sharpness were compared between gridded, CS, and twofold undersampled CS reconstructions. Observations were validated in gas‐exchange data collected from 15 healthy and 25 post‐hematopoietic‐stem‐cell‐transplant participants.Results: CS reconstructions in simulations yielded images with threefold increases in accuracy. CS increased sharpness and contrast for ventilation in vivo imaging and showed greater accuracy for undersampled acquisitions. CS improved gas‐exchange imaging, particularly in the dissolved‐phase where apparent‐SNR improved, and structure was made discernable. Finally, CS showed repeatability in important global gas‐exchange metrics including median dissolved‐gas signal ratio and median angle between real/imaginary components.Conclusion: A non‐Cartesian CS reconstruction approach that incorporates hyperpolarized 129Xe decay processes is presented. This approach enables improved image sharpness, contrast, and overall image quality in addition to up‐to threefold undersampling. This contribution benefits all hyperpolarized gas MRI through improved accuracy and decreased scan durations.