Sylvie Escribano

Sylvie Escribano

Auto-generated profile, based on publicly available information

Sylvie Escribano

University Grenoble Alpes, F-38000 Grenoble, France

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2018 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
MCM. Chandesris
M. Chandesris
LGL. Guetaz
L. Guetaz
PSP. Schott
P. Schott
MSM. Scohy
M. Scohy
SES. Escribano
S. Escribano
Proton Exchange Membrane Fuel cells (PEMFCs) durability of stacks operated under reformate is investigated with a special focus on the heterogeneity of aging. During an aging test at constant load, the local performances were investigated in situ using a segmented circuit board and a specific CO poisoning diagnostic tool based on the transition from pure hydrogen to reformate containing carbon monoxide. The heterogeneities analyses are supported with multi-physic simulations which highlight the heterogeneous CO coverage along the anode, as well as the competition between both electrodes leading to non-monotonous current density profiles. At the end of life, electrochemical and transmission electron microscopy analyses were performed on three characteristic zones (air inlet/H2 outlet, middle and air outlet/H2 inlet) of the Membrane Electrode Assembly (MEA). These experimental investigations put in evidence that the cathode outlet aged more severely than the cathode inlet, while more CO tolerance was lost at the anode outlet. The degradation by the electrochemical Ostwald ripening mechanism of the Pt3Co nanoparticles at the cathode outlet is suspected to pollute the ionomer, leading to the observed accelerating performance losses. Finally, optimized MEAs have been designed to mitigate the suspected degradation mechanisms, and tested at stack level demonstrating a clear durability improvement.

1 September 2018 in Journal of Power Sources
Verified
Journal Article
Closed access
CRClaudio Rabissi
Claudio Rabissi
PGP. Gazdzicki
P. Gazdzicki
LGL. Guétaz
L. Guétaz
SES. Escribano
S. Escribano
LGL. Grahl-Madsen
L. Grahl-Madsen
ACA. Casalegno
A. Casalegno

16 March 2018 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
IPIrina Profatilova
Irina Profatilova
PJPierre-André Jacques
Pierre-André Jacques
SESylvie Escribano
Sylvie Escribano
Development of efficient accelerated stress test protocols for polymer electrolyte membrane fuel cells (PEMFCs) is an extremely important topic closely related to FC lifetime prediction and a decrease of the FC test costs. This work is dedicated to precise investigation of the impact of various accelerating factors on a FC performance over 1000 h scale. Five identical membrane electrode assemblies with Pt-based catalysts on the cathode and PtRu-based catalyst on the anode were studied using load cycling protocols. The impact of accelerating aging stressors and their combinations, such as carbon monoxide in fuel, frequency and amplitude of current cycling and regular electrochemical diagnostics via polarization curves and cyclic voltammograms measurements was thoroughly investigated. In addition, electrochemical cell behavior under fixed and varied fuel compositions is addressed. Total and irreversible cell performance losses are quantified for different aging tests. It is shown that the importance of aging factors can change depending on a test duration. This study combines large amount of experimental electrochemical data giving quantitative ranking for the importance of factors accelerating cell aging in operation conditions close to real ones for stationary fuel cells.

18 October 2018 in Journal of Power Sources
Verified
Journal Article
Open access
CRClaudio Rabissi
Claudio Rabissi
MZMatteo Zago
Matteo Zago
PGP. Gazdzicki
P. Gazdzicki
LGL. Guétaz
L. Guétaz
SES. Escribano
S. Escribano
ACA. Casalegno
A. Casalegno
Durability issues of direct methanol fuel cell still hinder technology widespread commercialization; uneven aging of MEA components, generally harsher in air outlet region, is known to exasperate overall performance degradation. In a previous work, the authors selected a stable cathode electrode, demonstrated to fade homogenously: uneven water-related limitations, such as dehydration and flooding, were revealed to locally worsen performance at cathode inlet and outlet regions, leading to current redistribution. Aiming to reduce degradation rate, in this work homogeneous current distribution during operation is pursued by tuning MEA properties to meet local operating conditions. A properly improved 1D+1D physical model is used to support the development of a gradient MEA, featuring 1.6 mg cm−2 and 0.8 mg cm−2 of catalyst and ionomer respectively at inlet/outlet and center regions of cathode electrode. Tests based on custom macro-segmented cell demonstrated 55% more homogeneous current distribution, controllable during operation by means of cathode air stoichiometry. 500 h degradation test revealed 70% decreased degradation rate from uniform MEA (11 μV h−1) with a homogenous fading of performance. An 18% lower Pt nanoparticle growth at cathode outlet and limited ionomer degradation at cathode inlet were identified by ex-situ analyses (TEM and XPS), indicating locally mitigated fading mechanisms.

17 October 2016 in Processes
Verified
Journal Article
Open access
PDF file
Jose Luis VivienteJose Luis Viviente
Jose Luis Viviente
SESylvie Escribano
Sylvie Escribano
Giampaolo ManzoliniGiampaolo Manzolini
Giampaolo Manzolini
MSMarit Stange
Marit Stange
CTCarlo Tregambe
Carlo Tregambe
Fausto GallucciFausto Gallucci
Fausto Gallucci
This paper reports the findings of a FP7/FCH JU project (ReforCELL) that developed materials (catalysts and membranes) and an advance autothermal membrane reformer for a micro Combined Heat and Power (CHP) system of 5 kWel based on a polymer electrolyte membrane fuel cell (PEMFC). In this project, an active, stable and selective catalyst was developed for the reactions of interest and its production was scaled up to kg scale (TRL5 (TRL: Technology Readiness Level)). Simultaneously, new membranes for gas separation were developed. In particular, dense supported thin palladium-based membranes were developed for hydrogen separation from reactive mixtures. These membranes were successfully scaled up to TRL4 and used in lab-scale reactors for fluidized bed steam methane reforming (SMR) and autothermal reforming (ATR) and in a prototype reactor for ATR. Suitable sealing techniques able to integrate the different membranes in lab-scale and prototype reactors were also developed. The project also addressed the design and optimization of the subcomponents (BoP) for the integration of the membrane reformer to the fuel cell system.

1 September 2019 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
SESylvie Escribano
Sylvie Escribano
FMFabrice Micoud
Fabrice Micoud
LGLaure Guetaz
Laure Guetaz
Proton Exchange Membrane Fuel Cell (PEMFC) technologies are considered as a promising and clean energy supply for both transportation and stationary applications. State of art components present performance enabling integration of stacks in actual systems and vehicles. However, durability still needs to be improved as well as overall system cost still needs to be reduced to enable large scale competitive deployment. To this end, extensive investigations are required and conducted to improve understanding of the degradation mechanisms. The work presented is dedicated to the degradation phenomena occurring on MEA components at stack level, taking into account the interactions between the overall and local ageing conditions, respectively induced by the ageing mode and the design, and the local losses. The intention is to support the development of accelerated stress tests for automotive application to be validated on single cells and later-on on specific stack designs in the frame of a dedicated European project [1]. Performance and MEAs degradation are considered to identify causes and mechanisms for both reversible and non-reversible losses. Our main focus is to clarify interactions between global and local conditions as well as between performance losses and components degradation. The approach is applied on aged samples after their ageing in stacks following different load profiles. Pre-ageing, during ageing and post-ageing characterizations of MEA are performed at multiple scales considering in-situ averaged performance and electrochemical properties, in-situ distribution of local conditions such as current density, temperature and water when available, ex-situ local electrochemical properties and components microstructure. Among ageing modes considered in our studies, post-mortem data are available for MEA components after ageing in stacks following long term ageing on test bench, with fixed load steps or adapted drive cycles, or after use in a vehicle as range extender; for comparison, tests are performed with same stack design (active area 220 cm²), similar components and operating conditions. At stack scale, full understanding requires to add local measurements for correlating performance degradation and cell design. Two methods are applied and as far as possible combined to get these local data: current density distribution maps are performed using a segmented cell implemented in the middle of the stacks and post-mortem analyses are conducted on aged samples selected from specific zones (near gases inlet or outlets, middle) of stack-size aged MEAs, by electrochemical measurements in small differential single cells and by advanced electron microscopy techniques, then compared to non-aged samples. Local analyses are conducted so as to identify known mechanisms depending on the zones such as mainly carbon corrosion, platinum or cobalt dissolution and induced ionomer contamination. Results show differences in local effects when applying different ageing modes and the correlation between local conditions related to the design, alterations in the electrodes and performance losses. The image illustrates the multiple-scales characterization approach with a full stack, one 220 cm² MEAs used for post-mortem analyses, one 2 cm² MEA as tested in the small differential cell for electrochemical post-ageing measurements and examples of cyclic voltammograms and SEM/TEM images obtained on local samples from selected zones. [1] Acknowledgements - This work is mainly conducted in the frame of the project ID-FAST. This project has received funding from the Fuel Cells and Hydrogen 2 Joint Undertaking under the European Union’s Horizon 2020 research and innovation program under grant agreement No. 779565. Figure 1