Fabrice Micoud

Fabrice Micoud

Auto-generated profile, based on publicly available information

Fabrice Micoud

Univ. Grenoble Alpes, CEA, LITEN, Grenoble, France

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2022 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
TDTimothée Drugeot
Timothée Drugeot
FMFabrice Micoud
Fabrice Micoud
EPEric Pinton
Eric Pinton
SRSébastien Rosini
Sébastien Rosini
JPJean-Philippe POIROT-CROUVEZIER
Jean-Philippe POIROT-CROUVEZIER
YBYann Bultel
Yann Bultel

11 September 2024 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
TDTimothée Drugeot
Timothée Drugeot
RWRaky Wane
Raky Wane
FMFabrice Micoud
Fabrice Micoud
EPEric Pinton
Eric Pinton
LGLaure Guetaz
Laure Guetaz
Yann BultelYann Bultel
Yann Bultel

1 February 2026 in Journal of Applied Electrochemistry
Verified
Journal Article
Open access
PDF file
RRRaphaël Riasse
Raphaël Riasse
SRSébastien Rosini
Sébastien Rosini
FMFabrice Micoud
Fabrice Micoud
Cyclic voltammetry (CV) is a very commonly used technique for the study of electrochemical interfaces. Its application to proton exchange membrane fuel cell (PEMFC) is of great interest as it is sensitive to change in the catalyst layer and membrane state-of-life. Using cyclic voltammograms, it is possible to easily obtain information on the catalyst roughness factor and the hydrogen cross-over current. This study focuses on the best way to perform CV on individual cells at the stack level. To prevent the whole stack polarisation, eight different connection configurations have been tested to obtain comparable CV as the reference case with current applied on the whole stack. The comparison between the cyclic voltammograms and potentiostatic electrochemical impedance spectroscopy (PEIS) for all these configurations lead to some recommendations for bipolar plates design. Contact resistances and proximity of current and potential connections are the main hindrances to the measurement of reliable CV. The authors advise to maximise as much as possible the number of connection pins and to place them on both sides of the PEMFC bipolar plates. If it is not possible on current design, the authors recommend the use of dynamic ohmic drop compensation to minimise the error regarding the determination of roughness factor. Graphical abstract

1 September 2019 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
AMArnaud Morin
Arnaud Morin
SLSandrine Lyonnard
Sandrine Lyonnard
SESylvie Escribano
Sylvie Escribano
GGGerard Gebel
Gerard Gebel
JLJongmin Lee
Jongmin Lee
FMFabrice Micoud
Fabrice Micoud
The Proton Exchange Membrane Fuel Cell (PEMFC) is a highly complex energy conversion device coupling several electrochemical and transport phenomena occurring on a wide range of length-scales within a multilayered structure, named Membrane Electrodes Assembly (MEA). The fundamental description of all phenomena involved in PEMFC operation and degradation, and more particularly their interplay, is a contemplated pivotal requirement for improvements. This is a grand challenge, as a number of unsolved questions remain. In fact, all relevant physical and electrochemical phenomena are not fully identified or quantified. In the PEMFC, water plays a crucial role, since it is not only the main product of the electrochemical reaction but, above all, it is the fundamental common denominator to all the phenomena. In a real stack, as an open system converting H2 and O2, the operation and degradation are intrinsically heterogeneous resulting especially in a complex 3D distribution of water in the volume of the MEA. Among the most important component of the MEA is the ionomer, made of a PerFluoroSulfonic Acid (PFSA) polymer, which acts as a solid electrolyte to transfer proton and water to, from, and within the electrodes. The presence of highly hydrophilic sulfonic acid groups makes it, most probably, the most sensitive MEA component toward water activity/content. Indeed, it governs its swelling, structure as well as transport and mechanical properties. This property of the ionomer, along with its role, explains why PEMFC behaviour is so dependent on water activity. Still very recently, a work of Kongkanand et al.[1] emphasizes how ionomer is a crucial electrodes' constituent in view of enhancing performance. For these reasons, many researches are still devoted to studying the ionomer in relation with water activity and as well as to quantifying the 3D water distribution during PEMFC operation. It is well known that Small Angle Scattering (SAS) is the most suitable technique to characterize the structure of the ionomer[2]. A side from that, neutron is the probe of choice to quantify water within operating PEMFC[3]. For these reasons, we have been developing for several years SAS techniques, either with Neutrons or X-Ray, in order to measure simultaneously and operando, the water distribution and the ionomer nanostructure. Spatial and time resolutions offew µm² and 50 ms, respectively, have been achieved with the last generation of X-Rays sources such as the one of European Synchrotron Radiation Facility (ESRF), and ~4 mm² and 30 s with high neutron flux on D22 beamline at Laue Langevin Institute (ILL)[4],[5]. Thus, it is possible to follow the kinetics during transient. In particular, we have shown that, within the membrane, local water content is greater in front of the current collecting rib than in front of the gas supply channel. We have also evidenced some evolution of the physical structure of the membrane upon aging in real conditions depending on the local water content. We thus pushed forward these techniques, which now allows us to have unique information on the local water activity and ionomer structure within the CL. Our results demonstrate how SAS techniques are powerful to assess the main current scientific and technological issues of the PEMFC. [1] Kongkanand et al., ACS Energy Lett. 2018, 3, 618−621 [2] Fumagalli et al., J. Phys. Chem. B 2015, 119, 7068−7076 [3] Boillat et al., Current Opinion in Electrochemistry 2017, 5, 3–10 [4] Morin et al., J. Electrochem. Soc. 2016, 163, F9-F21 [5] Martinez et al., ACS Advanced Energy Materials 2019 Figure 1

4 February 2026 in Journal of Applied Electrochemistry
Verified
Journal Article
Open access
PDF file
RRRaphaël Riasse
Raphaël Riasse
DGDamien Gloriod
Damien Gloriod
MCMarine Cornet
Marine Cornet
MTMarine Trégaro
Marine Trégaro
GLGuillaume Laphitz
Guillaume Laphitz
FMFabrice Micoud
Fabrice Micoud
Proton exchange membrane fuel cell (PEMFC) electrodes have been extensively studied at multiple levels. As the operation of such system is heterogeneous, several strategies have risen to get insights in local current density. Segmented current collecting plates for single cells or local post mortem analysis for large cells and stacks have been the preferred ways so far to study the local evolution of the electrodes during or after aging studies. Following a previous study on the best practices to carry out cyclic voltammetry (CV) on an individual cell at the stack level, this work introduces a novel use of commercial S++® measurement card, already integrated in stacks to measure local current density in nominal operation (≈ 1–3 A cm−2), for the measurement of local catalyst roughness factors during cyclic voltammograms (≈ 10 mA cm−2). The results show that, independently of the connection configuration used, the S++® card gives global CV measurement overlapping with the one of the potentiostat. However, one shall be careful since the local current density distribution appears to be very dependant of the connection configuration. Single cell polarisation did not enable proper local distribution as it suffered from current redistribution within the bipolar plate facing the S++®. The authors thus introduced and validated here the overlap configuration to obtain trustworthy local current measurements by shifting current collection one cell away from the studied cell. Reliable local CV could therefore be measured by polarising the smallest number of cells as possible (3 cells) instead of the whole stack. Graphical abstract

30 July 2026 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
CRCharline Rémy
Charline Rémy
FMFabrice Micoud
Fabrice Micoud
AFArmelle Fabulet
Armelle Fabulet
BGBenoit Gouze
Benoit Gouze
SRSébastien Rosini
Sébastien Rosini
AMArnaud Morin
Arnaud Morin
This study evaluates break-in protocols for Pt/Vulcan-XC-72 cathode-based membrane electrode assemblies in PEMFCs. Fast, high-current protocols, lasting under 20 min at low voltage, were compared to a conventional 7-hour constant current procedure. The rapid protocols yielded to higher initial performance and saved up to 91.5% for hydrogen consumption. To elucidate governing mechanisms during break-in, electrochemical analyses were performed. Paradoxically, performance improved despite a modest decrease in electrochemical surface area, notably, voltage cycling induced a 16% specific surface loss, versus 5% for holding. While high-frequency resistance decreased by 16%–19% due to fast membrane hydration, its impact on performance remained modest. Instead, catalyst layer effective protonic resistance ( R eff, H+, CL ) emerged as the dominant factor governing performance, attributed to the reduction of proton transport limitation. Fast protocols yielded significant R eff, H+, CL reductions up to 38%, respectively, whereas the long protocol showed no significant change. These gains correlate with an increase in PtOx coulometry reduction charge and refined CO stripping peak shifted to lower potential, consistent with slight particle growth. These findings indicate that break-in is primarily a hydration-driven restructuring of the catalyst/ionomer interface rather than simple surface cleaning. These mechanisms-based understanding validates rapid protocols for industrial use.