1 February 2014 in Sensors and Actuators A: Physical
25 September 2013 in IEEE Sensors Journal
This paper investigates a wearable approach to facial electromyography and electrooculography. The aim is to reduce discomfort and setup time in electromyographic research, rehabilitation, and computer control. A screen and stencil printed passive electrode network is fabricated on a textile headband. When this headband is worn, an array of stencil printed electrodes makes contact with the skin. The electrodes are connected to external electronics by screen printed flexible conductive tracks. The printed electrode headband is used in a facial electromyographic control system to evaluate performance. The system can be used to control a mouse cursor or simulate keyboard functions. It was found that 50 Hz noise levels in the printed textile electrodes were similar to commercial disposable electroencephalography electrodes. The effect of a wearable approach on pressure variations and motion artefact is examined. The way in which this influences the design and performance of the control system is discussed.
1 January 2015 in Sensors and Actuators A: Physical
3 January 2014 in Measurement Science and Technology
1 September 2016 in Journal of Renewable and Sustainable Energy
MRMohammad Amin Rezaienia
This paper presents the wind tunnel experimental results to investigate the effects of surface gradient-of-curvature on aerodynamic performance of a low Reynolds number airfoil Eppler 387 for use in small-scale wind turbines. The prescribed surface curvature distribution blade design method is applied to the airfoil E387 to remove the gradient-of-curvature discontinuities and the redesigned airfoil is denoted as A7. Both airfoils are manufactured with high precision to reflect the design. Low-speed wind tunnel experiments are conducted to both airfoils at chord based Reynolds numbers 100 000, 200 000, and 300 000. Surface pressure measurements are used to calculate the lift and pitching-moment data, and the wake survey method is applied to obtain the drag data. The experimental results of E387 are compared with NASA Low Turbulence Pressure Tunnel (LTPT) results for validation. The gradient-of-curvature discontinuities of E387 result in a larger laminar separation bubble which causes higher drag at lower angles of attack. As the angle of attack increases the separation bubble of the airfoil E387 moves faster towards the leading edge than that of A7, resulting in a premature bubble bursting and earlier stall on E387. The impact of the gradient-of-curvature distribution on the airfoil performance is more profound at higher angles of attack and lower Reynolds number. The aerodynamic improvements are integrated over the 3D geometry of a 3 kW small wind turbine, resulting in up to 10% increase in instantaneous power and 1.6% increase in annual energy production. It is experimentally concluded that an improved curvature distribution results in a better airfoil performance, leading to higher energy output efficiency.
1 January 2017 in ASAIO Journal
TKTheodosios Korakianitis
The application of centrifugal pumps as heart assist devices imposes design limitations on the impeller geometry. Geometry and operating parameters will affect the performance and the hemocompatibility of the device. Among all the parameters affecting the hemocompatibility, pressure, rotational speed, blade numbers, angle, and width have significant impact on the blood trauma. These parameters directly (pressure, speed) and indirectly (geometry) affect the efficiency of the pump as well. This study describes the experimental investigation on geometric parameters and their effect on the performance of small centrifugal pumps suitable for Mechanical Circulatory Support (MCS) devices. Experimental and numerical techniques were implemented to analyze the performance of 15 centrifugal impellers with different characteristics. The effect of each parameter on the pump performance and hemolysis was studied by calculating the normalized index of hemolysis (NIH) and the shear stress induced in each pump. The results show five and six blades, 15–35° outlet angle, and the lowest outlet width that meets the required pressure rise are optimum values for an efficient hemocompatible pump.