Frederic Bouisset

Dr. Frederic Bouisset

Department of Cardiology, Toulouse Rangueil University Hospital, UMR 1295 INSERM, Hôpital Rangueil, CHU Toulouse, Toulouse, France
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
FBFrederic Bouisset
Frederic Bouisset
JRJean-Bernard Ruidavets
Jean-Bernard Ruidavets
JDJean Dallongeville
Jean Dallongeville
MMMarie Moitry
Marie Moitry
MMMichele Montaye
Michele Montaye
JFJean Ferrières
Jean Ferrières
Background: Available data comparing long-term prognosis according to the type of acute coronary syndrome (ACS) are scarce, contradictory, and outdated. Our aim was to compare short- and long-term mortality in ST-elevated (STEMI) and non-ST-elevated myocardial infarction (non-STEMI) ACS patients. Methods: Patients presenting with an inaugural ACS during the year 2006 and living in one of the three areas in France covered by the Monitoring of Trends and Determinants in Cardiovascular Disease (MONICA) registry were included. Results: A total of 1822 patients with a first ACS—1121 (61.5%) STEMI and 701 (38.5%) non-STEMI—were included in the study. At the 28-day follow-up, the mortality rates were 6.7% and 4.7% (p = 0.09) for STEMI and non-STEMI patients, respectively, and after adjustment of potential confounding factors, the 28-day probability of death was significantly lower for non-STEMI ACS patients (Odds Ratio = 0.58 (0.36–0.94), p = 0.03). At the 10-year follow-up, the death rates were 19.6% and 22.8% (p = 0.11) for STEMI and non-STEMI patients, respectively, and after adjustment of potential confounding factors, the 10-year probability of death did not significantly differ between non-STEMI and STEMI events (OR = 1.07 (0.83–1.38), p = 0.59). Over the first year, the mortality rate was 7.2%; it then decreased and stabilized at 1.7% per year between the 2nd and 10th year following ACS. Conclusion: STEMI patients have a worse vital prognosis than non-STEMI patients within 28 days following ACS. However, at the 10-year follow-up, STEMI and non-STEMI patients have a similar vital prognosis. From the 2nd year onwards following the occurrence of a first ACS, the patients become stable coronary artery disease patients with an annual mortality rate in the 2% range, regardless of the type of ACS they initially present with.

1 July 2017 in Canadian Journal of Cardiology
Verified
Journal Article
Closed access
SBStéphanie Blanco
Stéphanie Blanco
JFJean Ferrières
Jean Ferrières
VBVanina Bongard
Vanina Bongard
OTOlivier Toulza
Olivier Toulza
FSFatia Sebai
Fatia Sebai
FBFrederic Bouisset
Frederic Bouisset

23 December 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SHSebastien Hascoet
Sebastien Hascoet
GSGrzegorz Smolka
Grzegorz Smolka
TKTeoman Kilic
Teoman Kilic
Reda IbrahimReda Ibrahim
Reda Ibrahim
EOEustaquio Maria Onorato
Eustaquio Maria Onorato
BGBenoit Gerardin
Benoit Gerardin
Prosthetic paravalvular leaks (PVLs) are associated with congestive heart failure and hemolysis. Surgical PVL closure carries high risks. Transcatheter implantation of occluding devices in PVL is a lower risk but challenging procedure. Of the available devices, only two have been specifically approved in Europe for transcatheter PVL closure (tPVLc): the Occlutech® Paravalvular Leak Device (PLD) and Amplatzer™ ParaValvular Plug 3 (AVP 3). Here, we review the various tools and devices used for tPVLc, based on three observational registries including 748 tPVLc procedures performed in 2005–2021 at 33 centres in 11 countries. In this case, 12 registry investigators with over 20 tPVLc procedures each described their practical tips and tricks regarding imaging, approaches, delivery systems, and devices. They considered three-dimensional echocardiography to be the cornerstone of PVL assessment and procedure guidance. Anterograde trans-septal mitral valve and retrograde aortic approaches were used in most centres, although some investigators preferred the transapical approach. Hydrophilic-coated low-profile sheaths were used most often for device deployment. The AVP 3 and PLD devices were chosen for 89.0% of procedures. Further advances in design and materials are awaited. These complex procedures require considerable expertise, and experience accumulated over a decade has no doubt contributed to improve practices.

5 March 2024 in Journal of the American Heart Association
Verified
Journal Article
Open access
HOHirofumi Ohashi
Hirofumi Ohashi
TMTakuya Mizukami
Takuya Mizukami
JSjeroen sonck
jeroen sonck
FBFrederic Bouisset
Frederic Bouisset
BKBrian Ko
Brian Ko
CCCarlos Collet
Carlos Collet
Background: Following percutaneous coronary intervention (PCI), optical coherence tomography provides prognosis information. The pullback pressure gradient is a novel index that discriminates focal from diffuse coronary artery disease based on fractional flow reserve pullbacks. We sought to investigate the association between coronary artery disease patterns, defined by coronary physiology, and optical coherence tomography after stent implantation in stable patients undergoing PCI. Methods and Results: This multicenter, prospective, single‐arm study was conducted in 5 countries (NCT03782688). Subjects underwent motorized fractional flow reserve pullbacks evaluation followed by optical coherence tomography‐guided PCI. Post‐PCI optical coherence tomography minimum stent area, stent expansion, and the presence of suboptimal findings such as incomplete stent apposition, stent edge dissection, and irregular tissue protrusion were compared between patients with focal versus diffuse disease. Overall, 102 patients (105 vessels) were included. Fractional flow reserve before PCI was 0.65±0.14, pullback pressure gradient was 0.66±0.14, and post‐PCI fractional flow reserve was 0.88±0.06. The mean minimum stent area was 5.69±1.99 mm 2 and was significantly larger in vessels with focal disease (6.18±2.12 mm 2 versus 5.19±1.72 mm 2 , P =0.01). After PCI, incomplete stent apposition, stent edge dissection, and irregular tissue protrusion were observed in 27.6%, 10.5%, and 51.4% of the cases, respectively. Vessels with focal disease at baseline had a lower prevalence of incomplete stent apposition (11.3% versus 44.2%, P =0.002) and more irregular tissue protrusion (69.8% versus 32.7%, P <0.001). Conclusions: Baseline coronary pathophysiological patterns are associated with suboptimal imaging findings after PCI. Patients with focal disease had larger minimum stent area and a higher incidence of tissue protrusion, whereas stent malapposition was more frequent in patients with diffuse disease.

1 December 2021 in International Journal of Cardiology
Verified
Journal Article
Closed access
FBFrederic Bouisset
Frederic Bouisset
ADAntoine Deney
Antoine Deney
JFJean Ferrières
Jean Ferrières
VPVassili Panagides
Vassili Panagides
MBMathieu Becker
Mathieu Becker
GCGuillaume Cayla
Guillaume Cayla

25 January 2018 in Journal of Interventional Cardiology
Verified
Journal Article
Open access
PDF file
MHMarco Hernández‐Enríquez
Marco Hernández‐Enríquez
FCFrancisco Campelo‐Parada
Francisco Campelo‐Parada
TLThibault LHERMUSIER
Thibault LHERMUSIER
FBFrederic Bouisset
Frederic Bouisset
Jerome RoncalliJerome Roncalli
Jerome Roncalli
NBNicolas Boudou
Nicolas Boudou
Objectives: To analyze the procedural and long‐term outcomes of the use of rotational atherectomy (RA) in underexpanded stents in our cohort and to provide an overview of currently available data on this technique.Background: Stent underexpansion (SU) has been related to stent thrombosis and restenosis. RA has been used to treat undilatable SU as a bail‐out strategy with encouraging results.Methods: This is an observational, single‐center study. We included patients who underwent stentablation between 2013 and 2017. Baseline demographics, procedural results, in‐hospital major adverse cardiac events (MACE), and long‐term follow‐up MACE were retrospectively collected.Results: A total of 11 patients (90.9% males, mean age 65.4 ± 18.6) were included in this study. Median left ventricle ejection fraction was 53.5% [46.2‐55]. Median calculated Syntax score was 16 [9‐31] and 45.5% of patients were admitted for acute coronary syndrome. Radial approach was used in 63.6% of cases. Most patients only required one burr (45% used a 1.5 mm diameter burr) during the intervention. Procedural success was achieved in 90.9% of the cases. Acute lumen gain was 42.7% [30.7‐61.49]. There were no in‐hospital deaths or MACE. At a median follow‐up of 26 months, only one patient (9.1%) suffered MACE in the context of acute coronary syndrome, and two patients (18.2%) required non‐target lesion revascularization. No deaths were reported.Conclusions: RA of under expanded stents is a feasible option with a high rate of procedural success. At long‐term follow‐up, all of them were alive and 90.9% of patients remained free from MACE.