Juan Contreras

Juan Contreras

Auto-generated profile, based on publicly available information

Juan Contreras

Earth Sciences Division, CICESE, Ensenada, Mexico

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2000 in Journal of Structural Geology
Verified
Journal Article
Closed access
JCJuan Contreras
Juan Contreras
MAMark H. Anders
Mark H. Anders
CSChristopher H. Scholz
Christopher H. Scholz

1 January 1998 in Geology
Verified
Journal Article
Closed access
CSChristopher H. Scholz
Christopher H. Scholz
JCJuan C. Contreras
Juan C. Contreras

10 April 1997 in Journal of Geophysical Research
Verified
Journal Article
Closed access
PDF file
JCJuan Contreras
Juan Contreras
CSChristopher H. Scholz
Christopher H. Scholz
GKGeoffrey C. P. King
Geoffrey C. P. King

1 December 2017 in Earth and Planetary Science Letters
Verified
Journal Article
Closed access
FNFlorian Neumann
Florian Neumann
RNRaquel Negrete-Aranda
Raquel Negrete-Aranda
RHRobert N. Harris
Robert N. Harris
JCJuan Contreras
Juan Contreras
JSJohn G. Sclater
John G. Sclater
AGAntonio González-Fernández
Antonio González-Fernández

8 October 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SPSammy A. Perdomo
Sammy A. Perdomo
VOViviana Ortega
Viviana Ortega
AJAndres Jaramillo-Botero
Andres Jaramillo-Botero
NMNelson Mancilla
Nelson Mancilla
JMJose-Hernando Mosquera-DeLaCruz
Jose-Hernando Mosquera-DeLaCruz
JRJhonattan de la Roche
Jhonattan de la Roche
A critical path to solving the SARS-CoV-2 pandemic, without further socioeconomic impact, is to stop its spread. For this to happen, pre- or asymptomatic individuals infected with the virus need to be detected and isolated opportunely. Unfortunately, there are no current ubiquitous (i.e., ultra-sensitive, cheap, and widely available) rapid testing tools capable of early detection of SARS-CoV-2 infections. In this article, we introduce an accurate, portable, and low-cost medical device and bio-nanosensing electrode dubbed SenSARS and its experimental validation. SenSARS’ device measures the electrochemical impedance spectra of a disposable bio-modified screen-printed carbon-based working electrode (SPCE) to the changes in the concentration of SARS-CoV-2 antigen molecules (“S” spike proteins) contained within a sub-microliter fluid sample deposited on its surface. SenSARS offers real-time diagnostics and viral load tracking capabilities. Positive and negative control tests were performed in phosphate-buffered saline (PBS) at different concentrations (between 1 and 50 fg/mL) of SARS-CoV-2(S), Epstein–Barr virus (EBV) glycoprotein gp350, and Influenza H1N1 M1 recombinant viral proteins. We demonstrate that SenSARS is easy to use, with a portable and lightweight (< 200 g) instrument and disposable test electrodes (<U.S. $\$ $ 5), capable of fast diagnosis (~10 min), with high analytical sensitivity (low limits of detection, LOD = 1.065 fg/mL, and quantitation, LOQ = 3.6 fg/mL) and selectivity to SARS-CoV-2(S) antigens, even in the presence of structural proteins from the other pathogens tested. SenSARS provides a potential path to pervasive rapid diagnostics of SARS-CoV-2 in clinical, point-of-care, and home-care settings, and to breaking the transmission chain of this virus. Medical device compliance testing of SenSARS to EIC-60601 technical standards is underway.

12 February 2023 in Basin Research
Verified
Journal Article
Open access
FNFlorian Neumann
Florian Neumann
RNRaquel Negrete‐Aranda
Raquel Negrete‐Aranda
RHRobert N. Harris
Robert N. Harris
JCJuan Contreras
Juan Contreras
CGChristophe Y. Galerne
Christophe Y. Galerne
ESExpedition 385 Scientists
Expedition 385 Scientists
Heat flow is estimated at eight sites drilled int the Guaymas Basin, Gulf of California, during the International Ocean Discovery Program Expedition 385. The expedition sought to understand the thermal regime of the basin and heat transfer between off‐axis sills intruding the organic‐rich sediments of the Guaymas Basin, and the basin floor. The distinct sedimentation rates, active tectonics, and magmatism make the basin interesting for scientific discoveries. Results show that sedimentation corrected heat flow values range 119–221 mW/m2 in the basin and 257–1003 mW/m2 at the site of a young sill intrusion, denominated Ringvent. Thermal analysis shows that heat in the Guaymas Basin is being dissipated by conduction for plate ages >0.2 Ma, whereas younger plate ages are in a state of transient cooling by both conduction and advection. Drilling sites show that Ringvent is an active sill being cooled down slowly by circulating fluids with discharge velocities of 10–200 mm/yr. Possible recharge sites are located ca. 1 km away from the sill's border. Modelling of the heat output at Ringvent indicates a sill thickness of ca. 240 m. A simple order‐of‐magnitude model predicts that relatively small amounts of magma are needed to account for the elevated heat flow in non‐volcanic, sediment‐filled rifts like the central and northern Gulf of California in which heating of the upper crust is achieved via advection by sill emplacement and hydrothermal circulation. Multiple timescales of cooling control the crustal, chemical and biological evolution of the Guaymas Basin. Here, we recognize at least four timescales: the time interval between intrusions (ca. 103 yr), the thermal relaxation time of sills (ca. 104 yr), the characteristic cooling time of the sediments (ca. 105 yr), and the cooling of the entire crust at geologic timescales.