Jhonattan de la Roche

Jhonattan de la Roche

Auto-generated profile, based on publicly available information

Jhonattan de la Roche

Universidad Nacional de Colombia

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 December 2020 in Journal of the European Ceramic Society
Verified
Journal Article
Closed access
JRJhonattan de la Roche
Jhonattan de la Roche
PGPablo Andrés Gómez
Pablo Andrés Gómez
JJuan Manuel Alvarado Orozco
Juan Manuel Alvarado Orozco
ATAlejandro Toro
Alejandro Toro

8 October 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SPSammy A. Perdomo
Sammy A. Perdomo
VOViviana Ortega
Viviana Ortega
AJAndres Jaramillo-Botero
Andres Jaramillo-Botero
NMNelson Mancilla
Nelson Mancilla
JMJose-Hernando Mosquera-DeLaCruz
Jose-Hernando Mosquera-DeLaCruz
JRJhonattan de la Roche
Jhonattan de la Roche
A critical path to solving the SARS-CoV-2 pandemic, without further socioeconomic impact, is to stop its spread. For this to happen, pre- or asymptomatic individuals infected with the virus need to be detected and isolated opportunely. Unfortunately, there are no current ubiquitous (i.e., ultra-sensitive, cheap, and widely available) rapid testing tools capable of early detection of SARS-CoV-2 infections. In this article, we introduce an accurate, portable, and low-cost medical device and bio-nanosensing electrode dubbed SenSARS and its experimental validation. SenSARS’ device measures the electrochemical impedance spectra of a disposable bio-modified screen-printed carbon-based working electrode (SPCE) to the changes in the concentration of SARS-CoV-2 antigen molecules (“S” spike proteins) contained within a sub-microliter fluid sample deposited on its surface. SenSARS offers real-time diagnostics and viral load tracking capabilities. Positive and negative control tests were performed in phosphate-buffered saline (PBS) at different concentrations (between 1 and 50 fg/mL) of SARS-CoV-2(S), Epstein–Barr virus (EBV) glycoprotein gp350, and Influenza H1N1 M1 recombinant viral proteins. We demonstrate that SenSARS is easy to use, with a portable and lightweight (< 200 g) instrument and disposable test electrodes (<U.S. $\$ $ 5), capable of fast diagnosis (~10 min), with high analytical sensitivity (low limits of detection, LOD = 1.065 fg/mL, and quantitation, LOQ = 3.6 fg/mL) and selectivity to SARS-CoV-2(S) antigens, even in the presence of structural proteins from the other pathogens tested. SenSARS provides a potential path to pervasive rapid diagnostics of SARS-CoV-2 in clinical, point-of-care, and home-care settings, and to breaking the transmission chain of this virus. Medical device compliance testing of SenSARS to EIC-60601 technical standards is underway.


1 January 2015 in Ingeniare. Revista chilena de ingeniería
Verified
Journal Article
Open access
PDF file
CBClaudia Milena Bedoya-Hincapié
Claudia Milena Bedoya-Hincapié
JRJhonattan de la Roche
Jhonattan de la Roche
Elisabeth Restrepo-ParraElisabeth Restrepo-Parra
Elisabeth Restrepo-Parra
JEJose Edgar
Jose Edgar
JOJhon Jairo Olaya
Jhon Jairo Olaya
Bismuth thin films were grown onto glass substrates through the DC magnetron sputtering technique. The effects of substrate temperature on the microstructure of the films were evaluated. The structural behavior was analyzed via X-ray diffraction, and it showed a marked influence of the substrate temperature on the crystallite size and the micro-stress. The morphologies evaluated through Electron Probe Micro-analyzer images indicated a slight difference in the grain size with an increase in temperature as well as a significant increase in surface roughness, according to profilometer measurements.

1 October 2018 in DYNA
Verified
Journal Article
Open access
PDF file
JRJhonattan De la Roche-Yepes
Jhonattan De la Roche-Yepes
Juan Manuel Manuel González CarmonaJuan Manuel Manuel González Carmona
Juan Manuel Manuel González Carmona
Elisabeth Restrepo-ParraElisabeth Restrepo-Parra
Elisabeth Restrepo-Parra
HSHector Sanchez-Sthepa
Hector Sanchez-Sthepa
Titanium-doped tungsten disulfide thin films (WS2-Ti) were deposited using a DC magnetron co-sputtering on AISI 304 stainless steel and silicon substrates. Different Ti cathode power densities between 0 and 1.25 W/cm2 were used for coating deposition. Energy-dispersive spectroscopy evidenced an increase in Ti percentage at the expense of W, as well as a sulfur deficiency. Raman spectroscopy was used to identify bands corresponding to W-S for undoped WS2. As the material was doped, changes in crystalline structure caused W-S main bands to separate. Scratch adhesion testing showed that Ti percentage increased along with the critical load (Lc). Furthermore, adhesive failure type changed from plastic to elastic. Finally, corrosion resistance analysis using electrochemical impedance spectroscopy (EIS) showed that, at high Ti concentrations, corrosion resistance was enhanced as Ti facilitates coating densification and generates a protective layer.