1 December 2024 in TELKOMNIKA (Telecommunication Computing Electronics and Control)
SSSuhariningsih Suhariningsih
Suhariningsih Suhariningsih
Multi-step constant current-constant voltage charging method to improve CC-CV method on lead acid batteries
31 October 2020 in Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering)
The lighting system is one of the biggest uses of electrical energy. Currently, lighting systems, especially emergency lighting, are urgently needed to deal with sudden blackouts at night. The emergency lighting gets a source of electrical energy from the battery and the battery gets a source of electrical energy from PLN. To regulate the source of electrical energy, a DC-DC converter with a bidirectional method is used. The bidirectional converter is a converter that has 2 functions, namely buck mode and boost mode which works when the main source of PLN goes out, automatically the lighting system will be supplied by the battery as a backup source. The buck mode in the charging process is used to store electrical energy into a battery with a battery capacity of 12V 30Ah. While the boost mode in the discharging process is used to distribute electrical energy from the battery to the load with a lamp load of 10W. The charging and discharging processes are controlled using proportional integral control analytic methods. The charging process in buck mode with a Kp value of 8.62 and Ki of 17240, the output voltage value is 13.99V. While the discharging process in boost mode with a Kp value of 2.44 and Ki of 344.63, the output voltage value is 23.99V.
15 June 2019 in EMITTER International Journal of Engineering Technology
Renewable energy sources require an energy storage system because its are fluctuating and electricity producing at certain times, even sometimes not in accordance with the needs of the load. To maintain continuity of electricity, smart battery energy storage system is needed. Therefore, this paper of a full-bridge bidirectional DC-DC Converter (FB-BDC) with Fuzzy Logic Control (FLC) is designed and implemented for battery energy storage application. The FLC has error and delta error of voltage level as input and duty cycle of FB-BDC as output. The FB-BDC is controlled by a microcontroller ARM Cortex-M4F STM32F407VG for voltage mode control. The FB-BDC topology is selected becuase battery storage system needed isolated and need high voltage ratio both for step-up and step-down. The main purpose of FB-BDC to perform bidirectional energy transfer both of DC-Bus and battery. Moreover, FB-BDC controls the DC-Bus voltage according to referenced value. The power flow and voltage on DC-Bus is controlled by FLC with voltage mode control. The experiment result shows the ability of FLCÂ voltage mode control to control FB-BDC on regulate charging voltage with an error 1% and sharing voltage 1.5% form referenced value.
31 December 2018 in INOVTEK POLBENG
Energi listrik yang mampu dibangkitkan oleh photovoltaic (PV) sangat dipengaruhi oleh faktor-faktor eksternal seperti intensitas iradiasi matahari, suhu lingkungan dan orientasi sudut kemiringan dari pemasangan PV. Intensitas iradiasi matahari di permukaan bumi selalu berubah-ubah nilainya seiring dengan pergerakan matahari di langit mulai matahari terbit sampai terbenam. Pada makalah ini akan dibahas PV solar tracker dengan reflektor cermin datar untuk mendapatkan intensitas iradiasi matahari yang maksimal sepanjang hari. Penggunaan reflektor dalam makalah ini bertujuan untuk meningkatkan diffuse irradiance dan memperpendek jarak tempuh pergerakan solar tracker sehingga lebih hemat energi. Solar tracker didesain bergerak otomatis mengikuti posisi matahari dengan memperbarui sudut solar tracker sesuai sun hour angle (sudut jam matahari) secara periodik 1 jam sekali. Penentuan sudut solar tracker dikontrol oleh mikrokontroler ATMega16. Hasil percobaan lapangan diperoleh daya yang mampu dihasilkan PV menggunakan solar tracker dengan reflektor cermin datar setiap jamnya mengalami kenaikan daya rata-rata sebesar 76.05% dibandingkan dengan PV terpasang statis. Secara komulatif dalam satu hari energi didapatkan posentase kenaikan energi dapat mencapai 75.20% dibandingkan dengan PV yang dipasang secara statis. Sedangkan konsumsi energi untuk menggerakkan solar tracker memerlukan energy kurang dari 0.15% dari total energi yang mampu dihasilkan oleh PV.
15 June 2019 in EMITTER International Journal of Engineering Technology
Due to increase power quality which are caused by harmonic distortion it could be affected malfunction electrical equipment. Therefore, identification of harmonic loads become important attention in the power system. According to those problems, this paper proposes a Load Identification using harmonic based on probabilistic neural network (PNN). Harmonic is obtained by experiment using prototype, which it consists of microcontroller and current sensor. Fast Fourier Transform (FFT) method to analyze of current waveform on loads become harmonic load data. PNN is used to identify the type of load. To load identification, PNN is trained to get the new weight. Testing is conducted To evaluate of the accuracy of the PNN from combination of four loads. The results demonstrate that this method has high accuracy to determine type of loads based on harmonic load