26 June 2018 in AIP Conference Proceedings
Photovoltaic (PV) module is used to convert solar energy to electrical energy. The output power of PV module is affected by the amount of irradiation of sun and temperature of PV module. The problem that may occur is partial shading caused by some objects such as trees, building, clouds, and so on. The impact of this condition is the decrease of output power of PV and the maximum power point (MPP) become more than one. Maximum power point of P-V characteristic curve will be more than one such as GMPP (Global Maximum Power Point) and LMPP (Local Maximum Power Point). This case cannot be solved using the ordinary MPPT (Maximum Power Point Tracking) method because the maximum power is trapped on wrong point, it is LMPP. Therefore, to overcome this problem, Modified P&O (Perturb and Observe) method is proposed as a MPPT method under partial shading condition. The proposed method is implemented on SEPIC converter to get actual maximum power point (GMPP). Experiment results prove the Modified P&O method can generate greater power and faster charging process on battery. The State of Charge of battery increases about 30% if the Modified P&O method, which is applied on battery charging system.
1 February 2020 in TELKOMNIKA (Telecommunication Computing Electronics and Control)
Power factor improvement on LED lamp driver using BIFRED converter
31 July 2023 in JAREE (Journal on Advanced Research in Electrical Engineering)
Cubicle 20 kV is a crucial electrical equipment in the 20 kV power distribution system. Often, cubicle issues arise due to excessively low or high temperatures and humidity, which can lead to the presence of water spots and corrosion on the components inside the 20 kV cubicle. One of the efforts to maintain the reliability of this 20 kV cubicle is to ensure that the temperature and humidity inside the cubicle remain within their operational limits. To achieve this, a system is needed to control the temperature and humidity in the 20 kV cubicle. The system can monitor and control the temperature and humidity inside the cubicle by adjusting the activation angle of the exhaust fan and heater. Control is achieved using a multiple-input, multiple-output fuzzy logic controller. The main components of this system are the STM32 microcontroller, DHT22 sensor, and ESP8266 module for monitoring temperature and humidity via a website. System has successfully controlled temperature and humidity d with a set point value of 35 °C and humidity of 60% RH. This implementation of fuzzy multiple input multiple outputs has performed well and resulted in only a small error of 0.55% for temperature and 1.05% for humidity.With the presence of this device, the temperature and humidity in the cubicle 20 kV can be controlled, and it enables the PLN operator to easily monitor and maintain the cubicle 20 kV.
1 November 2019 in Journal of Physics: Conference Series
Electrical energy is very important for everyday life. The need of electrical energy increasing every year. However, the solar panel source has a weakness. The output power of solar panel is still fluctuating depending on ambient temperature and solar irradiantions on the solar panel. Irradiation is the radiant of energy that comes from the sun. To overcome the problem the Maximum Power Point Tracking is needed so it can make solar panel work at its optimum point. This Maximum Power Point Method is looking for the largest current and voltage read by solar panel using the Lagrange Interpolation method. By using Maximum Power Point Tracking, the output power is expected to be optimal with constant voltage and current so that the battery’s lifetime is not damaged quickly. This method can track Maximum Power Point whenever irradiation changes occur. The converter used in this Maximum Power Point Tracking is the SEPIC Converter. This converter can convert DC to DC voltage in higher or lower voltage without changing its polarity. In this paper, Lagrange Interpolation method has average error in output power of 1,96%.
1 March 2021 in IOP Conference Series: Materials Science and Engineering
This Paper is explain about how to design a Multilevel Boost Converter (MLBC). This Converter is a Boost Converter with an upgrade of Parallel Diode Circuit and Capacitors Circuit. MLBC (Multi Level Boost Converter) have more advantages with low voltage input change to high voltage output. The Principle of MLBC is like the Boost Converter, but they have high ratio conversion without adding transformation for step up the voltage, the setting Output will stabilize if they always get the minimum input range for reduce the drop voltage from input who used Solar Panel, it is used MISO (Multiplied Input Single Output), the MISO contains Solar Panel and Battery with the parallel circuit set. DC Micro Grid using as DC BUS for distributed the voltage from the source to load for the maximum output power it used 100-200 Watt. The Method of control voltage it used PI - Ziegler Nichols-1 for controlled the Multi Input Single Output (MISO) block, the first control used to make the input of MLBC stabilize for 30 - 40 V being step up to 200 - 250 Volt. The Load of DC BUS example: Inverter, 3 Phase Motor, Led DC, Battery Energy Storage at this project used a inverter with 3 phase motor for load of converter. The Maximum Output Power from a design of this converter is 234.87 Watt according the DC load and the efficiency of converter is maximum 86 %.