Jessica A. M. Bastiaansen

Jessica A. M. Bastiaansen

Auto-generated profile, based on publicly available information

Jessica A. M. Bastiaansen

Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Switzerland

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2013 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
TCTian Cheng
Tian Cheng
Mor MishkovskyMor Mishkovsky
Mor Mishkovsky
JBJessica A. M. Bastiaansen
Jessica A. M. Bastiaansen
OOOlivier Ouari
Olivier Ouari
PHPatrick Hautle
Patrick Hautle
ACArnaud Comment
Arnaud Comment

1 August 2013 in Biochimica et Biophysica Acta (BBA) - General Subjects
Verified
Journal Article
Closed access
JBJessica A.M. Bastiaansen
Jessica A.M. Bastiaansen
TCTian Cheng
Tian Cheng
Mor MishkovskyMor Mishkovsky
Mor Mishkovsky
JDJoão Duarte
João Duarte
ACArnaud Comment
Arnaud Comment
RGRolf Gruetter
Rolf Gruetter

5 September 2017 in Dalton Transactions
Verified
Journal Article
Closed access
PDF file
DBDebora Bonvin
Debora Bonvin
JBJessica A. M. Bastiaansen
Jessica A. M. Bastiaansen
MSMatthias Stuber
Matthias Stuber
HHHeinrich Hofmann
Heinrich Hofmann
MEMarijana Mionic Ebersold
Marijana Mionic Ebersold
Folic acid directly bound to the surface of iron oxide nanoparticles with simultaneously high targeting, MRI relaxivity and heating efficacy.

6 May 2016 in Scientific Reports
Verified
Journal Article
Open access
JBJessica A. M. Bastiaansen
Jessica A. M. Bastiaansen
MMMatthew E. Merritt
Matthew E. Merritt
ACArnaud Comment
Arnaud Comment
Cardiac dysfunction is often associated with a shift in substrate preference for ATP production. Hyperpolarized (HP) 13C magnetic resonance spectroscopy (MRS) has the unique ability to detect real-time metabolic changes in vivo due to its high sensitivity and specificity. Here a protocol using HP [1-13C]pyruvate and [1-13C]butyrate is used to measure carbohydrate versus fatty acid metabolism in vivo. Metabolic changes in fed and fasted Sprague Dawley rats (n = 36) were studied at 9.4 T after tail vein injections. Pyruvate and butyrate competed for acetyl-CoA production, as evidenced by significant changes in [13C]bicarbonate (−48%), [1-13C]acetylcarnitine (+113%) and [5-13C]glutamate (−63%), following fasting. Butyrate uptake was unaffected by fasting, as indicated by [1-13C]butyrylcarnitine. Mitochondrial pseudoketogenesis facilitated the labeling of the ketone bodies [1-13C]acetoacetate and [1-13C]β-hydroxybutyryate, without evidence of true ketogenesis. HP [1-13C]acetoacetate was increased in fasting (250%) but decreased during pyruvate co-injection (−82%). Combining HP 13C technology and co-administration of separate imaging agents enables noninvasive and simultaneous monitoring of both fatty acid and carbohydrate oxidation. This protocol illustrates a novel method for assessing metabolic flux through different enzymatic pathways simultaneously and enables mechanistic studies of the changing myocardial energetics often associated with disease.

17 May 2018 in ACS Chemical Neuroscience
Verified
Journal Article
Open access
YTYuhei Takado
Yuhei Takado
TCTian Cheng
Tian Cheng
JBJessica A. M. Bastiaansen
Jessica A. M. Bastiaansen
HYHikari A. I. Yoshihara
Hikari A. I. Yoshihara
BLBernard Lanz
Bernard Lanz
ACArnaud Comment
Arnaud Comment
The dynamics of l-lactate transport across the blood–brain barrier (BBB) and its cerebral metabolism are still subject to debate. We studied lactate uptake and intracellular metabolism in the mouse brain using hyperpolarized 13C magnetic resonance spectroscopy (MRS). Following the intravenous injection of hyperpolarized [1-13C]lactate, we observed that the distribution of the 13C label between lactate and pyruvate, which has been shown to be representative of their pool size ratio, is different in NMRI and C57BL/6 mice, the latter exhibiting a higher level of cerebral lactate dehydrogenase A (Ldha) expression. On the basis of this observation, and an additional set of experiments showing that the cerebral conversion of [1-13C]lactate to [1-13C]pyruvate increases after exposing the brain to ultrasound irradiation that reversibly opens the BBB, we concluded that lactate transport is rate-limited by the BBB, with a 30% increase in lactate uptake after its disruption. It was also deduced from these results that hyperpolarized 13C MRS can be used to detect a variation in cerebral lactate uptake of <40 nmol in a healthy brain during an in vivo experiment lasting only 75 s, opening new opportunities to study the role of lactate in brain metabolism.

27 August 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
JBJessica A.M. Bastiaansen
Jessica A.M. Bastiaansen
DPDavide Piccini
Davide Piccini
LSLorenzo Di Sopra
Lorenzo Di Sopra
CRChristopher W. Roy
Christopher W. Roy
JHJohn Heerfordt
John Heerfordt
MSMatthias Stuber
Matthias Stuber
Purpose: To implement, optimize, and test fast interrupted steady‐state (FISS) for natively fat‐suppressed free‐running 5D whole‐heart MRI at 1.5 tesla (T) and 3T.Methods: FISS was implemented for fully self‐gated free‐running cardiac‐ and respiratory‐motion‐resolved radial imaging of the heart at 1.5T and 3T. Numerical simulations and phantom scans were performed to compare fat suppression characteristics and to determine parameter ranges (number of readouts [NR] per FISS module and TR) for effective fat suppression. Subsequently, free‐running FISS data were collected in 10 healthy volunteers and images were reconstructed with compressed sensing. All acquisitions were compared with a continuous balanced steady‐state free precession version of the same sequence, and both fat suppression and scan times were analyzed.Results: Simulations demonstrate a variable width and location of suppression bands in FISS that were dependent on TR and NR. For a fat suppression bandwidth of 100 Hz and NR ≤ 8, simulations demonstrated that a TR between 2.2 ms and 3.0 ms is required at 1.5T, whereas a range of 3.0 ms to 3.5 ms applies at 3T. Fat signal increases with NR. These findings were corroborated in phantom experiments. In volunteers, fat SNR was significantly decreased using FISS compared with balanced steady‐state free precession (P < 0.05) at both field strengths. After protocol optimization, high‐resolution (1.1 mm3) 5D whole‐heart free‐running FISS can be performed with effective fat suppression in under 8 min at 1.5T and 3T at a modest scan time increase compared to balanced steady‐state free precession.Conclusion: An optimal FISS parameter range was determined enabling natively fat‐suppressed 5D whole‐heart free‐running MRI with a single continuous scan at 1.5T and 3T, demonstrating potential for cardiac imaging and noncontrast angiography.