17 June 2019 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
YHYaoyao He
Yaoyao He
SQShengxue Qin
Shengxue Qin
BDBrandon A. Dyer
Brandon A. Dyer
HZHongbin Zhang
Hongbin Zhang
LZLifen Zhao
Lifen Zhao
JQJianfeng Qiu
Jianfeng Qiu
Polyvinyl chloride (PVC) is a commonly used tissue‐mimicking material (TMM) for phantom construction using 3D printing technology. PVC‐based TMMs consist of a mixture of PVC powder and dioctyl terephthalate as a softener. In order to allow the clinical use of a PVC‐based phantom use across CT and magnetic resonance imaging (MRI) imaging platforms, we evaluated the mechanical and physical imaging characteristics of ten PVC samples. The samples were made with different PVC‐softener ratios to optimize phantom bioequivalence with physiologic human tissue. Phantom imaging characteristics, including computed tomography (CT) number, MRI relaxation time, and mechanical properties (e.g., Poisson’s ratio and elastic modulus) were quantified. CT number varied over a range of approximately −10 to 110 HU. The relaxation times of the T1‐weighted and T2‐weighted images were 206.81 ± 17.50 and 20.22 ± 5.74 ms, respectively. Tensile testing was performed to evaluate mechanical properties on the three PVC samples that were closest to human tissue. The elastic moduli for these samples ranged 7.000–12.376 MPa, and Poisson’s ratios were 0.604–0.644. After physical and imaging characterization of the various PVC‐based phantoms, we successfully produced a bioequivalent phantom compatible with multimodal imaging platforms for machine calibration and image optimization/benchmarking. By combining PVC with 3D printing technologies, it is possible to construct imaging phantoms simulating human anatomies with tissue equivalency.

11 May 2024 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
XGXiaofang Guo
Xiaofang Guo
YHYaoyao He
Yaoyao He
ZYZilong Yuan
Zilong Yuan
TNTingting Nie
Tingting Nie
YLYulin Liu
Yulin Liu
HXHaibo Xu
Haibo Xu

8 July 2020 in Acta Radiologica
Verified
Journal Article
Closed access
PDF file
HCHao Chen
Hao Chen
YHYaoyao He
Yaoyao He
CZCecheng Zhao
Cecheng Zhao
LZLili Zheng
Lili Zheng
NPNing Pan
Ning Pan
ZYZilong Yuan
Zilong Yuan
Background: The reproducibility of intravoxel incoherent motion (IVIM)-based radiomics studies in humans has not been reported. Purpose: To determine the inter- and intra-observer variability on the reproducibility of IVIM-based radiomics features in cervical cancer (CC). Material and Methods: The IVIM images of 25 patients with CC were retrospectively collected. Based on the high-resolution T2-weighted images, the regions of interest (ROIs) were independently delineated twice in diffusion-weighted images at a b value of 1000 s/mm2 (interval time was one month) by two radiologists. This was done at the largest transversal cross-sections of the tumors. The ROI was subsequently used in apparent diffusion coefficient (ADC), true diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) maps derived from IVIM images. In total, 105 radiomics features were then finally extracted from the IVIM-derived maps. The inter- and intra-observer reproducibility of IVIM-derived features was then evaluated using the intraclass correlation coefficient. Results: Inter- and intra-observer variability affected the reproducibility of radiomics features. D* map had 100% and 95% reproducible features, ADC map had 89% and 93%, D map had 97% and 86%, while f map had 54% and 62% reproducible features with good to excellent reliability in the intra-observer analysis. Similarly, D* map had 90% and 94%, ADC map had 85% and 70%, D map had 81% and 78%, while f map had 41% and 93% reproducible features with good to excellent reliability in the inter-observer analysis. Conclusion: Inter- and intra-observer variability can affect radiomics analysis. Cognizant to this, multicenter studies should pay more attention to intra- and inter-observer variability.

22 June 2022 in British Journal of Radiology
Verified
Journal Article
Closed access
YHYaoyao He
Yaoyao He
HCHao Chen
Hao Chen
HZHuiting Zhang
Huiting Zhang
RGRobert Grimm
Robert Grimm
CZCecheng Zhao
Cecheng Zhao
ZYZilong Yuan
Zilong Yuan
Objective: To shorten acquisition time of readout segmentation of long variable echo trains (RESOLVE)-based diffusion kurtosis imaging (DKI) via Readout Partial Fourier (RPF) and b-value combinations. Methods: The RESOLVE-based DKI images of 38 patients with nasopharyngeal carcinoma (NPC) were prospectively enrolled. For RESOLVE-based DKI images with 5/8 RPF and without RPF, objective and subjective evaluations of image quality were performed. A total of nine groups with different b-value combinations were simulated, and the influence of different b-value combinations for RESOLVE-RPF-based DKI sequences was assessed using the intraclass correlation coefficient (ICC). Results: The mean values of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in DKI images without RPF were higher than those with 5/8 RPF (252.9 ± 77.7 vs 247.3 ± 85.5 and 5.8 ± 2.8 vs 5.4 ± 2.3, respectively), but not significantly (p = 0.460 and p = 0.180, respectively). In comparing the ICCs between nine groups of different b-value combinations in RESOLVE-RPF-based DKI, group (200, 800, 2000 s/mm2), group (200, 400, 800, 2000 s/mm2) and group (200, 800, 1500, 2000 s/mm2) were not significantly different (p > 0.001) and showed excellent agreement (0.81–1.00) with that of group (200, 400, 800, 1500, 2000 s/mm2). Using b-value optimization and RPF technology, the group with RPF (200, 400, 800, 2000 s/mm2) showed a 56% reduced scanning compared with the group without RPF (200, 400, 800, 1500, 2000 s/mm2; 3 min 46 s vs 8 min 31 s, respectively). Conclusion: DKI with RPF did not significantly affect image quality, but both RPF and different b-value combinations can affect the scanning time. The combination of RPF and b-value optimization can ensure the stability of DKI parameters and reduce the scanning time by 56%. Advances in knowledge: This work is to optimize scan parameters, e.g. RPF and b-value combinations, to reduce acquisition time for RESOLVE-based DKI in NPC. To our knowledge, the effect of RESOLVE-RPF and b-value combinations on DKI has not been reported.

29 August 2019 in Acta Radiologica
Verified
Journal Article
Closed access
PDF file
YHYaoyao He
Yaoyao He
YRYi Rong
Yi Rong
HCHao Chen
Hao Chen
ZZZhaoxi Zhang
Zhaoxi Zhang
JQJianfeng Qiu
Jianfeng Qiu
ZYZilong Yuan
Zilong Yuan
Background: The impact of variable b-value combinations on apparent diffusion coefficient (ADC)-based radiomics features has not been fully addressed in literature. Purpose: To investigate the correlation between radiomics features extracted from ADC maps and various b-value combinations in cervical cancer. Material and Methods: Diffusion-weighted images (b-values: 0, 600, 800, and 1000 s/mm2) of 20 patients with cervical cancer were included. Tumors were identified with the largest transversal cross-section and manually segmented by radiologist. For each b-value combination, 92 radiomics features were extracted and coefficient of variance (CV) was used to evaluate the robustness of radiomics features with different b-value combinations. Features with CV > 5% were normalized by the mean feature variation across the group. Results: Out of a total of 92 radiomics features, 18 were classified as robust features with CV ≤5%. Among the rest (CV > 5%), 11, 23, and 40 features demonstrated 5%< CV ≤10%, 10%< CV ≤20%, and CV > 20%, respectively. A subset of features in each category (CV > 5%) showed strong correlation with the b-value combination variation, including 44% (7/16) features in gray level co-occurrence matrix, 62% (8/13) features in gray level dependence matrix, 64% (9/14) features in first order, 50% (8/16) features in gray level run length matrix, 57% (8/14) features in gray level size matrix, and 20% (1/5) features in neighborhood gray-tone difference matrix. Conclusions: Variations in b-value combinations demonstrated impact on radiomics features extracted from ADC maps for cervical cancer. The radiomics features with CV <5% can be considered as robust features and are recommended to be used in multicenter radiomics studies.