1 December 2017 in Journal of Microwaves, Optoelectronics and Electromagnetic Applications
This paper proposes a new Frequency Selective Surface (FSS) with modifications on the Jerusalem Cross (JC) geometry to provide a multiband response. Fractal levels are created by introducing concentric self-similar JC copies in the original unit cell. This modification results in new dipoles at the structure which allows for the appearance of new bands proportional to these diploles’ lengths, while maintaining total unit cell size. Three fractal levels of the JC FSS are studied in this paper, and third level presents five resonant frequencies which are f1 = 1.78 GHz, f2 = 6.42 GHz, f3 = 8.69 GHz, f4 = 10.94 GHz and f5 = 12.98 GHz. Simulation results for the insertion loss (S21), surface current distribution and measurement results are presented.
24 November 2020 in Engineering Research Express
Eye bolts are part of a system used to anchor electrical insulators in substations and on transmission lines, connected by concrete structures. Structural failures in these devices may lead to service interruption, financial losses and risks for the general population. In this article, we propose a signal adapter capable of applying and receiving high frequency signals to a portable vector network analyzer for the eye bolt. The technique consists of injecting high frequency signals into the samples in order to detect their integrity and analyzing their return loss (S11), using the principle of reflection and transmission lines. Should the eye bolt present a failure, the ∣S11∣ response is changed, thereby enabling its detection. The development of the adapter, for both intact and defective bolt models, was based on electromagnetic simulation models using the Ansys HFSS program. The measurements were made with models of real bolts presenting approximate wear, in order to validate the simulations.
1 September 2023 in Journal of Microwaves, Optoelectronics and Electromagnetic Applications
This paper presents an eyebolt structural fault detection system, based on the analysis of multiple electromagnetic parameters through a random forest classifier trained by both measurements and high-fidelity simulated signals. The proposed methodology is completely noninvasive and does not require the disassembly of the electrical infrastructure, allowing the live-line working. The obtained results show that the proposed multi-parameter strategy achieves high accuracy and increases the system’s capability of detecting faults, improving the efficiency of the operator’s preventive maintenance routines and, consequently, increasing the reliability of the power supply and energy distribution systems.