Joshua D. Brooks

Joshua D. Brooks

Auto-generated profile, based on publicly available information

Joshua D. Brooks

Research Engineer, Aerospace Systems Design Lab, School of Aerospace Engineering, Georgia Institute of Technology, 275 Ferst Dr. NW, Atlanta, GA 30332. ORCID:

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2023 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
SJShin Young Jeong
Shin Young Jeong
MBMalavika V. Bagepalli
Malavika V. Bagepalli
JBJoshua D. Brooks
Joshua D. Brooks
DRDevesh Ranjan
Devesh Ranjan
ZZZhuomin Zhang
Zhuomin Zhang
PLPeter G. Loutzenhiser
Peter G. Loutzenhiser

23 May 2024 in Applied Thermal Engineering
Verified
Journal Article
Closed access
SJShin Young Jeong
Shin Young Jeong
MBMalavika V. Bagepalli
Malavika V. Bagepalli
JBJoshua D. Brooks
Joshua D. Brooks
DRDevesh Ranjan
Devesh Ranjan
ZZZhuomin M. Zhang
Zhuomin M. Zhang
PLPeter G. Loutzenhiser
Peter G. Loutzenhiser

9 April 2023 in Energy Nexus
Verified
Journal Article
Open access
JBJoshua D. Brooks
Joshua D. Brooks
DMDimitri N. Mavris
Dimitri N. Mavris

1 May 2023 in Journal of Sustainable Water in the Built Environment
Verified
Journal Article
Closed access
PDF file
JBJoshua D. Brooks
Joshua D. Brooks
JLJung-Ho Lewe
Jung-Ho Lewe
SDScott Duncan
Scott Duncan
DMDimitri Mavris
Dimitri Mavris
This work demonstrates how a water and energy sustainable building’s heating, ventilation, and air conditioning (HVAC) system may be operated to maximize condensate production while upholding user thermal comfort and energy consumption requirements. A physics-based HVAC condensate model was presented and validated against operating data from the Kendeda Building for Innovative Sustainable Design (KBISD), a 3,437.4-m2 (37,000-ft2 ) academic building on the Georgia Institute of Technology’s Atlanta campus. A sensitivity study of the HVAC condensate production and power consumption was performed. Metamodels were developed to concisely yet accurately represent the physics-based model, and these were used as the basis of an optimization exercise to identify competitive operating conditions for maximizing condensate production. The case studies included here found optimized HVAC system operation strategies to produce up to 708% more condensate. The demonstrated approach may be reproduced by system operators or building automation systems to increase condensate production without sacrificing building system-level energy and thermal comfort requirements. This work demonstrates how a building’s heating, ventilation, and air conditioning (HVAC) system may be operated to increase the amount of water, or condensate, which may be pulled out of the air and collected. A simple engineering model is presented and verified against real-world data. This is used as the basis for an optimization approach that allows operators to make strategic, mathematically substantiated decisions to impact the amount of condensate collected and the power required to do so. In addition, the use of so-called metamodels for reducing complex engineering models or systems into simple mathematical representations is exemplified for increasing the speed of the analyses performed in this work. These metamodels may be used to represent HVAC or other building systems and allow for optimization efforts similar to those presented herein or potentially model predictive control. The case studies discussed in this work bring the optimization approach and metamodels together to demonstrate how a building may theoretically be operated to increase its condensate production by 708% within reasonable power requirements and without sacrificing the comfort of the building’s occupants.

28 July 2021
Verified
Conference Paper
Closed access
JBJoshua Brooks
Joshua Brooks
JLJUNG-HO LEWE
JUNG-HO LEWE
EYEfe Yamac Yarbasi
Efe Yamac Yarbasi
WRWilliam Robertson
William Robertson
HKHyunwoo Kim
Hyunwoo Kim
Dimitri MavrisDimitri Mavris
Dimitri Mavris
View Video Presentation: https://doi.org/10.2514/6.2021-3363.vid Net positive water and energy buildings aim to generate or harvest more water and energy than they consume. Buildings pursuing this goal typically do so through the generation of energy using photovoltaic (PV) arrays and through the collection of rainwater using the building’s rooftop and a large cistern for storage. As PV systems are limited by their intermittency in power generation, energy storage systems (ESS) are being investigated to augment the availability of their generated power. Many ESS have been investigated, but little previous work has looked into the potential use of rainwater harvesting cisterns as passive thermal storage reservoirs for thermal-electric energy exchange. This work performed a simple investigatory study into this idea using actual data from an academic building located on Georgia Tech’s Atlanta campus. An energy and water building performance model was coupled with a cistern thermal energy storage model. The sensitivity of the building’s PV array area, cistern volume, maximum cistern temperature, and thermal-electric conversion efficiency are presented. The addition of a high specific heat material to the cistern is also evaluated and the impact of this addition is presented. Preliminary results suggest that an academic building may save up to 58% of its supplementary electrical demand by adopting a passive cistern thermal energy storage system.

1 November 2024 in Journal of Sustainable Water in the Built Environment
Verified
Journal Article
Closed access
JBJoshua D. Brooks
Joshua D. Brooks
JLJung-Ho Lewe
Jung-Ho Lewe
SDScott Duncan
Scott Duncan
DMDimitri Mavris
Dimitri Mavris