Xijie Feng

Xijie Feng

Auto-generated profile, based on publicly available information

Xijie Feng

College of Optical and Electronic Technology, China Jiliang University , Hangzhou, Zhejiang 310018

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2024 in Analytica Chimica Acta
Verified
Journal Article
Closed access
XFXijie Feng
Xijie Feng
ZRZiqiao Ren
Ziqiao Ren
YCYunjie Cao
Yunjie Cao
WSWenbo Sui
Wenbo Sui
FWFuxiang Wang
Fuxiang Wang
Changyu ShenChangyu Shen
Changyu Shen

23 October 2024 in Optics Letters
Verified
Journal Article
Closed access
JWJun Wu
Jun Wu
YSYufei Shi
Yufei Shi
XFXijie Fen
Xijie Fen
JZJun Zhou
Jun Zhou
JDJie Dong
Jie Dong
CSChangyu Shen
Changyu Shen
A humidity sensor for respiratory monitoring based on a tilted fiber Bragg grating (TFBG) functionalized with a nanoporous coating consisting of titanium carbide (Ti2C) and fullerene (C60) is proposed. By incorporating the C60 into Ti2C, a nanocomposite film with abundant three-dimensional porousness is coated on the TFBG surface. The nanocomposite film with strong hygroscopicity and desorption properties is highly sensitive to environmental humidity variations, where the induced refractive index changes of the coating result in the spectral responses of TFBG multi-resonances. Experimental results show that the sensitivity of the sensor is as high as 0.055 dB/%RH in the relative humidity range of 10–90%RH with the response and recovery time of 0.59 and 0.91 s, respectively. Furthermore, the humidity sensor was successfully used to perform in vivo respiratory monitoring of the humans.

2 December 2024 in Applied Physics Letters
Verified
Journal Article
Closed access
WSWenbo Sui
Wenbo Sui
ZRZiqiao Ren
Ziqiao Ren
YCYunjie Cao
Yunjie Cao
XFXijie Feng
Xijie Feng
FWFuxiang Wang
Fuxiang Wang
Changyu ShenChangyu Shen
Changyu Shen
The detection of human immunoglobulin G (human IgG) provides crucial evidence in diagnosis of infectious diseases and monitoring of therapeutic effects. Here, we propose a plasmonic fiber-optical surface plasmon resonance (SPR) based sensor to realize the ultralow limit human IgG detection. The proposed sensor is fabricated by attaching a mixture of 2H-MoS2 nanosheets with L-cysteine on a gold-coated tilted fiber Bragg grating. The 2H-MoS2 possesses a large specific surface area, where the L-cysteine can enhance the stability of antibody modification. The composite membrane of 2H-MoS2 and L-cysteine can adsorb more probe rabbit anti-human IgG, which can improve sensitivity of the proposed sensor. The experimental results show that the proposed sensor exhibits a response time of approximately 220 s and a sensitivity of 0.11 dB/(ng/ml). The limit of detection of 0.87 ng/ml of the proposed sensor is one order of magnitude lower than those of other fiber-optic SPR human IgG sensors.