Changyu Shen

Prof. Changyu Shen

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2012 in Optics Express
Verified
Journal Article
Closed access
PDF file
Changyu ShenChangyu Shen
Changyu Shen
CZChuan Zhong
Chuan Zhong
YYYang You
Yang You
JCJinlei Chu
Jinlei Chu
XZXin Zou
Xin Zou
HGHuaping Gong
Huaping Gong
A curvature sensor based on a polarization-dependent in-fiber Mach-Zehnder interferometer (MZI) is proposed. The MZI is fabricated by core-offset fusion splicing one section of polarization maintaining fiber (PMF) between two single mode fibers (SMFs). Two independent interference patterns corresponding to the two orthogonal polarization modes for the PMF are obtained. The couple efficiency between the core mode and the cladding mode decreased with the increasing of the bending on the MZI part. The curvature variation on the MZI part can be obtained by detecting the fringe visibility of the interference patterns. A difference arithmetic demodulation method is used to reduce the effects of the light source power fluctuations and temperature cross-sensitivity. Experimental results show that maximal sensitivity of −0.882 dB/m−1 is obtained under a measurement range of 0.1 to 0.35 m−1 for the curvature sensor. With the use of difference arithmetic demodulation method, the temperature-curvature cross-sensitivity and light source power fluctuations effects on the proposed sensor are decreased by 94% and 91%, respectively.

13 June 2019 in Applied Optics
Verified
Journal Article
Closed access
PDF file
LHLeyi Hou
Leyi Hou
CZChunliu Zhao
Chunliu Zhao
BXBen Xu
Ben Xu
BMBangning Mao
Bangning Mao
Changyu ShenChangyu Shen
Changyu Shen
DWD. N. Wang
D. N. Wang
A highly sensitive temperature sensor is demonstrated experimentally, which is fabricated based on a Fabry–Perot interferometer (FPI) filled with polydimethylsiloxane (PDMS). The sensor’s sensitivity is −0.653  nm/°C by utilizing the thermal expansion effect of PDMS, which has been greatly improved compared to that of the traditional FPI temperature sensor. Moreover, in order to further improve the sensitivity, a scheme where two parallel FPI structures are used to form the Vernier effect is proposed, which are a sensing FPI and reference FPI, respectively. Such a temperature sensor based on the FPI filled with PDMS and the Vernier effect exhibits a high temperature sensitivity of 17.758 nm/°C. Meanwhile, the proposed sensors show the advantages of high sensitivity, simplicity, and low cost.

18 December 2014 in Optics Express
Verified
Journal Article
Open access
PDF file
Changyu ShenChangyu Shen
Changyu Shen
YWYouqing Wang
Youqing Wang
JCJinlei Chu
Jinlei Chu
YLYanfang Lu
Yanfang Lu
YLYi Li
Yi Li
XDXinyong Dong
Xinyong Dong
A Mach-Zehnder interferometer (MZI) based fiber axial micro-displacement sensor was proposed. The MZI was constructed by a bowknot-type taper (BTT) combining with a fiber core-offset between two single mode fibers (SMFs). The axial micro-displacement of the core offset is correlated with the MZI transmission spectrum and varied with the interferometer arm length. For the arm length L of 12, 18, 24 and 30 mm, the proposed sensors showed high sensitivity of −0.362 dB/μm, −0.385 dB/μm, −0.332 dB/μm and −0.235dB/μm, and temperature errors of −0.056 dB/°C, −0.036 dB/°C, −0.044 dB/°C, −0.048 dB/°C, respectively. The theoretical simulations of the energy distributions were also given. The obtained sensitivity of −0.385 dB/μm is about 150 times high than that of the current similar existing axial micro-displacement sensor.

15 April 2019 in Optics Letters
Verified
Journal Article
Closed access
PDF file
DLDejun Liu
Dejun Liu
FLFengzi Ling
Fengzi Ling
RKRahul Kumar
Rahul Kumar
AMArun Kumar Mallik
Arun Kumar Mallik
Ke TianKe Tian
Ke Tian
PWPengfei Wang
Pengfei Wang
Liquid level measurement in lab on a chip (LOC) devices is a challenging task due to the demand for a sensor with ultra-high resolution but miniature in nature. In this Letter, we report a simple, compact in size, yet highly sensitive liquid level sensor based on a hollow core fiber (HCF) structure. The sensor is fabricated by fusion splicing a short section of HCF between two singlemode fibers (SMFs). Sensor samples with different lengths of HCF have been studied; it is found that the sensor with a HCF length of ∼4.73  mm shows the best sensitivity of ∼0.014  dB/μm, corresponding to a liquid level resolution of ∼0.7  μm, which is over five times higher than that of the previous reported fiber optic sensors to date. In addition, experimental results have demonstrated that the proposed sensor shows good repeatability of measurement and a very low cross sensitivity to changes in the refractive index of the surrounding medium.

9 January 2018 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Changyu ShenChangyu Shen
Changyu Shen
CZChuan Zhong
Chuan Zhong
DLDejun Liu
Dejun Liu
XLXiaokang Lian
Xiaokang Lian
JZJianyao Zheng
Jianyao Zheng
JDJohn F. Donegan
John F. Donegan
Small lateral forces (lower than 0.1 N) cannot normally be measured with conventional single-mode fiber-based sensors because of the high value of their Young modulus (>70  GPa). Here we demonstrate the measurement of lateral forces in the range from 0.2 to 1.4×10−3  N with a tilted fiber Bragg grating (TFBG) in conventional single-mode fiber pushed against the surface tension (ST) of a bead of water. The measured transmission changes of individual cladding mode resonances of the TFBG corresponding to these force values are of the order of 29 dB. Separate measurements of the contact angle between the surface of the water and the fiber are used to calibrate the sensor with help from the known value of ST for water. Once calibrated, a TFBG can be used to measure unknown forces in the same range or to measure an unknown ST, provided a separate force measurement is available.

23 August 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
Changyu ShenChangyu Shen
Changyu Shen
ZXZihan Xie
Zihan Xie
ZHENLIN HUANGZHENLIN HUANG
ZHENLIN HUANG
SYSasa Yan
Sasa Yan
WSWenbo Sui
Wenbo Sui
XZXianglong Zeng
Xianglong Zeng
With the unprecedented development of green and renewable energy sources, the proportion of clean hydrogen (H2) applications grows rapidly. Since H2 has physicochemical properties of being highly permeable and combustible, high-performance H2 sensors to detect and monitor hydrogen concentration are essential. This review discusses a variety of fiber-optic-based H2 sensor technologies since the year 1984, including: interferometer technology, fiber grating technology, surface plasma resonance (SPR) technology, micro lens technology, evanescent field technology, integrated optical waveguide technology, direct transmission/reflection detection technology, etc. These technologies have been evolving from simply pursuing high sensitivity and low detection limits (LDL) to focusing on multiple performance parameters to match various application demands, such as: high temperature resistance, fast response speed, fast recovery speed, large concentration range, low cross sensitivity, excellent long-term stability, etc. On the basis of palladium (Pd)-sensitive material, alloy metals, catalysts, or nanoparticles are proposed to improve the performance of fiber-optic-based H2 sensors, including gold (Au), silver (Ag), platinum (Pt), zinc oxide (ZnO), titanium oxide (TiO2), tungsten oxide (WO3), Mg70Ti30, polydimethylsiloxane (PDMS), graphene oxide (GO), etc. Various microstructure processes of the side and end of optical fiber H2 sensors are also discussed in this review.