Brian Joseph Pierre

Brian Joseph Pierre

Auto-generated profile, based on publicly available information

Brian Joseph Pierre

Sandia National Laboratories, Albuquerque, NM, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
BPBrian J. Pierre
Brian J. Pierre
FWFelipe Wilches-Bernal
Felipe Wilches-Bernal
David SchoenwaldDavid Schoenwald
David Schoenwald
RERyan T. Elliott
Ryan T. Elliott
DTDaniel J. Trudnowski
Daniel J. Trudnowski
JNJason C. Neely
Jason C. Neely
This paper describes the design and implementation of a proof-of-concept Pacific dc Intertie (PDCI) wide area damping controller and includes system test results on the North American Western Interconnection (WI). To damp inter-area oscillations, the controller modulates the power transfer of the PDCI, a ±500 kV dc transmission line in the WI. The control system utilizes real-time phasor measurement unit (PMU) feedback to construct a commanded power signal which is added to the scheduled power flow for the PDCI. After years of design, simulations, and development, this controller has been implemented in hardware and successfully tested in both open and closed-loop operation. The most important design specifications were safe, reliable performance, no degradation of any system modes in any circumstances, and improve damping to the controllable modes in the WI. The main finding is that the controller adds significant damping to the modes of the WI and does not adversely affect the system response in any of the test cases. The primary contribution of this paper, to the state of the art research, is the design methods and test results of the first North American real-time control system that uses wide area PMU feedback.

1 July 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
Kaitlyn GarifiKaitlyn Garifi
Kaitlyn Garifi
EJEmma S. Johnson
Emma S. Johnson
BABryan Arguello
Bryan Arguello
BPBrian J. Pierre
Brian J. Pierre
In the face of increasing natural disasters and an aging grid, utilities need to optimally choose investments to the existing infrastructure to promote resiliency. This paper presents a new investment decision optimization model to minimize unserved load over the recovery time and improve grid resilience to extreme weather event scenarios. Our optimization model includes a network power flow model which decides generator status and generator dispatch, optimal transmission switching (OTS) during the multi-time period recovery process, and an investment decision model subject to a given budget. Investment decisions include the hardening of transmission lines, generators, and substations. Our model uses a second order cone programming (SOCP) relaxation of the AC power flow model and is compared to the classic DC power flow approximation. A case study is provided on the 73-bus RTS-GMLC test system for various investment budgets and multiple hurricane scenarios to highlight the difference in optimal investment decisions between the SOCP model and the DC model, and demonstrate the advantages of OTS in resiliency settings. Results indicate that the network models yield different optimal investments, unit commitment, and OTS decisions, and an AC feasibility study indicates our SOCP resiliency model is more accurate than the DC model.

17 October 2018 in IEEE Power and Energy Technology Systems Journal
Verified
Journal Article
Open access
CLChristoph Lackner
Christoph Lackner
FWFelipe Wilches-Bernal
Felipe Wilches-Bernal
BPBrian J. Pierre
Brian J. Pierre
David SchoenwaldDavid Schoenwald
David Schoenwald
This paper describes the implementation of a tool to estimate latencies and data dropouts in communication networks transferring synchrophasor data defined by the C37.118 standard. The tool time tags synchrophasor packets at the time it receives them according to a GPS clock and with this information is able to determine the time those packets took to reach the tool. The tool is able to connect simultaneously to multiple PMUs sending packets at different reporting rates with different transport protocols such as UDP or TCP. The tool is capable of redistributing every packet it receives to a different device, while recording the exact time this information is re-sent into the network. The results of measuring delays from a PMU using this tool are presented and compared with those of a conventional network analyzer. The results show that the tool presented in this work measures delays more accurately and precisely than the conventional network analyzer.

26 February 2021 in IEEE Open Access Journal of Power and Energy
Verified
Journal Article
Open access
SRS. Raja
S. Raja
BABryan Arguello
Bryan Arguello
BPBrian J. Pierre
Brian J. Pierre
This paper presents a novel dynamic programming (DP) technique for the determination of optimal investment decisions to improve power distribution system reliability metrics. This model is designed to select the optimal small-scale investments to protect an electrical distribution system from disruptions. The objective is to minimize distribution system reliability metrics: System Average Interruption Duration Index (SAIDI) and System Average Interruption Frequency Index (SAIFI). The primary input to this optimization model is years of recent utility historical outage data. The DP optimization technique is compared and validated against an equivalent mixed integer linear program (MILP). Through testing on synthetic and real datasets, both approaches are verified to yield equally optimal solutions. Efficiency profiles of each approach indicate that the DP algorithm is more efficient when considering wide budget ranges or a larger outage history, while the MILP model more efficiently handles larger distribution systems. The model is tested with utility data from a distribution system operator in the U.S. Results demonstrate a significant improvement in SAIDI and SAIFI metrics with the optimal small-scale investments.

18 September 2024 in IEEE Access
Verified
Journal Article
Open access
BABrent G. Austgen
Brent G. Austgen
MGManuel Garcia
Manuel Garcia
JYJoshua J. Yip
Joshua J. Yip
BABryan Arguello
Bryan Arguello
BPBrian J. Pierre
Brian J. Pierre
SSSurya Santoso
Surya Santoso
We propose a three-stage stochastic programming model to inform risk-averse investment in power system resilience to winter storms. The first stage pertains to long-term investment in generator winterization and mobile battery energy storage system (MBESS) resources, the second stage to MBESS deployment prior to an imminent storm, and the third stage to operational response. Serving as a forecast update, an imminent winter storm’s severity is assumed to be known at the time the deployment decisions are made. We incorporate conditional value-at-risk (CVaR) as the risk measure in the objective function to target loss, represented in our model by unserved energy, experienced during high-impact, low-frequency events. We apply the model to a Texas-focused case study based on the ACTIVS 2000-bus synthetic grid with winter storm scenarios generated using historical Winter Storm Uri data. Results demonstrate how the optimal investments are affected by parameters like cost and risk aversion, and also how effectively using CVaR as a risk measure mitigates the outcomes in the tail of the loss distribution over the winter storm impact uncertainty.

8 November 2019 in Electric Power Components and Systems
Verified
Journal Article
Open access
BPBrian J. Pierre
Brian J. Pierre
For high phase order (HPO) transmission systems, a major hurdle to overcome is the fault analysis and protection studies needed to guarantee successful implementation. This paper presents new equations which calculate the number of fault types and significant fault types of n-phase transmission lines. In addition, this paper defines and explains symmetrically significant fault types for HPO transmission systems. Lastly, this paper figuratively shows the significant fault types and symmetrically significant fault types for multiple HPO systems, n = 3, 4, 5, 6, 9, and 12. The equations and figures presented in this paper will assist in fault analysis and protective relay designs for HPO systems. The equations presented are used to determine the number of fault types a relay will need to account for, and the figurative approach shows the faults to be studied before HPO implementation.