Katherine R. Harrison

Katherine R. Harrison

Auto-generated profile, based on publicly available information

Katherine R. Harrison

Department of Civil & Environmental Engineering, University of Michigan

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2021 in Environmental Science & Technology
Verified
Journal Article
Open access
ZQZhong Qiao
Zhong Qiao
YYYinyin Ye
Yinyin Ye
ASAleksandra Szczuka
Aleksandra Szczuka
KHKatherine R. Harrison
Katherine R. Harrison
MDMichael C. Dodd
Michael C. Dodd
KWKrista R. Wigginton
Krista R. Wigginton
Free chlorine disinfection is widely applied to inactivate viruses by reacting with their biomolecules, which include nucleic acids, proteins, and lipids. Knowing the reactivities of viral genomes with free chlorine and the protection that encapsidation provides would ultimately help predict virus susceptibility to the disinfectant. The relative reactivities of different viral genome types and the impact of viral higher order structure with free chlorine are poorly characterized. Here, we studied the reactivity of viral genomes representing four genome types from virus particles with diverse structures, namely, (+)ssRNA (MS2), dsRNA (φ6), ssDNA (φX174), and dsDNA (T3) with free chlorine. We compared the reactivities of these viral nucleic acids when they were suspended in phosphate buffer solutions (naked forms) and when they were in the native virus particles (encapsidated forms). The reactivities of nucleic acids were tracked by polymerase chain reaction (PCR)-based assays. The naked dsDNA of T3 was the least reactive with free chlorine, with an average second order rate constant normalized by the number of bases in the measured regions (in M–1 s–1 b–1) that was 34×, 65×, and 189× lower than those of the dsRNA of φ6, ssRNA of MS2, and ssDNA of φX174, respectively. Moreover, different regions in the ssRNA genome of MS2 and the dsRNA genome of φ6 exhibited statistically different reaction kinetics. The genomes within virus particles reacted slower than the naked genomes overall, but the extent of these differences varied among the four viruses. The results on viral nucleic acid reactivity help explain different susceptibilities of viruses to inactivation by free chlorine and also provide a valuable comparison of the susceptibilities of different nucleic acids to oxidants.

1 September 2023 in Environmental Science & Technology
Verified
Journal Article
Open access
KHKatherine R. Harrison
Katherine R. Harrison
DSDelaney Snead
Delaney Snead
AKAnna Kilts
Anna Kilts
MAMichelle L. Ammerman
Michelle L. Ammerman
KWKrista R. Wigginton
Krista R. Wigginton
Virus concentrations measured in municipal wastewater help inform both the water treatment necessary to protect human health and wastewater-based epidemiology. Wastewater measurements are typically PCR-based, and interpreting gene copy concentrations requires an understanding of the form and stability of the nucleic acids. Here, we study the persistence of model virus genomes in wastewater, the protective effects provided by the virus capsids, and the relative decay rates of the genome and infectious viruses. In benchtop batch experiments in wastewater influent at 25 °C, extraviral (+)ssRNA and dsDNA amplicons degraded by 90% within 15-19 min and 1.6-1.9 h, respectively. When encapsidated, the T90 for MS2 (+)ssRNA increased by 424× and the T90 for T4 dsDNA increased by 52×. The (+)ssRNA decay rates were similar for a range of amplicon sizes. For our model phages MS2 and T4, the nucleic acid signal in untreated wastewater disappeared shortly after the viruses lost infectivity. Combined, these results suggest that most viral genome copies measured in wastewater are encapsidated, that measured concentrations are independent of assay amplicon sizes, and that the virus genome decay rates of nonenveloped (i.e., naked) viruses are similar to inactivation rates. These findings are valuable for the interpretation of wastewater virus measurements.

15 December 2020 in Open Forum Infectious Diseases
Verified
Journal Article
Open access
PDF file
KWKrista R Wigginton
Krista R Wigginton
PAPeter J Arts
Peter J Arts
HCHerek L Clack
Herek L Clack
WFWilliam J Fitzsimmons
William J Fitzsimmons
MGMirko Gamba
Mirko Gamba
KKKeith S. Kaye
Keith S. Kaye
Due to unprecedented shortages in N95 filtering facepiece respirators, healthcare systems have explored N95 reprocessing. No single, full-scale reprocessing publication has reported an evaluation including multiple viruses, bacteria, and fungi along with respirator filtration and fit. We explored reprocessing methods using new 3M 1860 N95 respirators, including moist (50%–75% relative humidity [RH]) heat (80–82°C for 30 minutes), ethylene oxide (EtO), pulsed xenon UV-C (UV-PX), hydrogen peroxide gas plasma (HPGP), and hydrogen peroxide vapor (HPV). Respirator samples were analyzed using 4 viruses (MS2, phi6, influenza A virus [IAV], murine hepatitis virus [MHV)]), 3 bacteria (Escherichia coli, Staphylococcus aureus, Geobacillus stearothermophilus spores, and vegetative bacteria), and Aspergillus niger. Different application media were tested. Decontaminated respirators were evaluated for filtration integrity and fit. Heat with moderate RH most effectively inactivated virus, resulting in reductions of >6.6-log10 MS2, >6.7-log10 Phi6, >2.7-log10 MHV, and >3.9-log10 IAV and prokaryotes, except for G stearothermohphilus. Hydrogen peroxide vapor was moderately effective at inactivating tested viruses, resulting in 1.5- to >4-log10 observable inactivation. Staphylococcus aureus inactivation by HPV was limited. Filtration efficiency and proper fit were maintained after 5 cycles of heat with moderate RH and HPV. Although it was effective at decontamination, HPGP resulted in decreased filtration efficiency, and EtO treatment raised toxicity concerns. Observed virus inactivation varied depending upon the application media used. Both moist heat and HPV are scalable N95 reprocessing options because they achieve high levels of biological indicator inactivation while maintaining respirator fit and integrity.

28 October 2020 in mSphere
Verified
Journal Article
Open access
PDF file
NRNicole Rockey
Nicole Rockey
PAPeter J. Arts
Peter J. Arts
LLLucinda Li
Lucinda Li
KHKatherine R. Harrison
Katherine R. Harrison
KLKathryn Langenfeld
Kathryn Langenfeld
KWKrista R. Wigginton
Krista R. Wigginton
Supply shortages of N95 respirators during the coronavirus disease 2019 (COVID-19) pandemic have motivated institutions to develop feasible and effective N95 respirator reuse strategies. In particular, heat decontamination is a treatment method that scales well and can be implemented in settings with variable or limited resources. Prior studies using multiple inactivation methods, however, have often focused on a single virus under narrowly defined conditions, making it difficult to develop guiding principles for inactivating emerging or difficult-to-culture viruses. We systematically explored how temperature, humidity, and virus deposition solutions impact the inactivation of viruses deposited and dried on N95 respirator coupons. We exposed four virus surrogates across a range of structures and phylogenies, including two bacteriophages (MS2 and phi6), a mouse coronavirus (murine hepatitis virus [MHV]), and a recombinant human influenza A virus subtype H3N2 (IAV), to heat treatment for 30 min in multiple deposition solutions across several temperatures and relative humidities (RHs). We observed that elevated RH was essential for effective heat inactivation of all four viruses tested. For heat treatments between 72°C and 82°C, RHs greater than 50% resulted in a >6-log10 inactivation of bacteriophages, and RHs greater than 25% resulted in a >3.5-log10 inactivation of MHV and IAV. Furthermore, deposition of viruses in host cell culture media greatly enhanced virus inactivation by heat and humidity compared to other deposition solutions, such as phosphate-buffered saline, phosphate-buffered saline with bovine serum albumin, and human saliva. Past and future heat treatment methods must therefore explicitly account for deposition solutions as a factor that will strongly influence observed virus inactivation rates. Overall, our data set can inform the design and validation of effective heat-based decontamination strategies for N95 respirators and other porous surfaces, especially for emerging viruses that may be of immediate and future public health concern. IMPORTANCE Shortages of personal protective equipment, including N95 respirators, during the coronavirus (CoV) disease 2019 (COVID-19) pandemic have highlighted the need to develop effective decontamination strategies for their reuse. This is particularly important in health care settings for reducing exposure to respiratory viruses, like severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that causes COVID-19. Although several treatment methods are available, a widely accessible strategy will be necessary to combat shortages on a global scale. We demonstrate that the combination of heat and humidity inactivates a range of RNA viruses, including both viral pathogens and common viral pathogen surrogates, after deposition on N95 respirators and achieves the necessary virus inactivation detailed by the U.S. Food and Drug Administration guidelines to validate N95 respirator decontamination technologies. We further demonstrate that depositing viruses onto surfaces when suspended in culture media can greatly enhance observed inactivation, adding caution to how heat and humidity treatment methods are validated.

16 July 2019 in Environmental Science: Water Research & Technology
Verified
Journal Article
Closed access
PDF file
AKAnthony D. Kappell
Anthony D. Kappell
KHKatherine R. Harrison
Katherine R. Harrison
PMPatrick McNamara
Patrick McNamara
Antibiotic resistant bacteria (ARB) and antibiotic resistance genes (ARGs) have been shown to increase in abundance in drinking water distribution systems (DWDS). Metals are a known stressor for the selection of ARB and the ARGs they harbor, and zinc orthophosphate is one corrosion inhibitor added to finished drinking waters. The potential impact of zinc orthophosphate on antibiotic resistance in drinking water remains unknown. The goal of this study was to determine the possible effects of zinc orthophosphate on the relative abundance of ARB and ARGs. Increasing concentrations of zinc orthophosphate, ranging from 0 to 10 mg L−1 orthophosphate equivalence, were added to 1 L microcosms inoculated with source water and mixed for 14 days. Direct plating with nine antibiotics was performed on days 0, 3, 7, and 14 resulting in total heterotrophic bacterial counts (THC). Significant differences were observed in the relative abundance of ARB over time for rifampicin, ampicillin, erythromycin, and trimethoprim resistant heterotrophic bacteria during exposure to zinc orthophosphate. Quantitative-PCR revealed that there was also a significant difference in the absolute and relative abundance of intI1, sul2, and qacH genes, dependent on the concentration of zinc orthophosphate. Additionally, water treated with equivalent orthophosphate concentrations of zinc orthophosphate, zinc chloride, and sodium orthophosphate indicated that the zinc component of zinc orthophosphate was the selective pressure of antibiotic resistance through promoting growth. The corrosion inhibitor, zinc orthophosphate, selects for ARB and ARGs while sodium orthophosphate did not impact ARB and ARGs suggesting sodium orthophosphate or sodium silicate may be preferred corrosion inhibitors in controlling antibiotic resistance in DWDS.

30 April 2020 in medRxiv
Verified
Preprint
Open access
PDF file
KWKrista R. Wigginton
Krista R. Wigginton
PAPeter J. Arts
Peter J. Arts
HCHerek Clack
Herek Clack
WFWilliam J Fitzsimmons
William J Fitzsimmons
MGMirko Gamba
Mirko Gamba
KKKeith S. Kaye
Keith S. Kaye
Importance: Filtering facepiece respirators, including N95 masks, are a critical component of infection prevention in hospitals. Due to unprecedented shortages in N95 respirators, many healthcare systems have explored reprocessing of N95 respirators. Data supporting these approaches are lacking in real hospital settings. In particular, published studies have not yet reported an evaluation of multiple viruses, bacteria, and fungi along with respirator filtration and fit in a single, full-scale study. Objective: We initiated a full-scale study to evaluate different N95 FFR decontamination strategies and their impact on respirator integrity and inactivating multiple microorganisms, with experimental conditions informed by the needs and constraints of the hospital. Methods: We explored several reprocessing methods using new 3M™ 1860 N95 respirators, including dry (<10% relative humidity) and moist (62-66% relative humidity) heat (80-82 °C) in the drying cycle of industrial instrument washers, ethylene oxide (EtO), pulsed xenon UV (UV-PX), hydrogen peroxide gas plasma (HPGP), and vaporous hydrogen peroxide (VHP). Respirator samples were treated and analyzed for biological indicator inactivation using four viruses (MS2, phi6, influenza A virus, murine hepatitis virus), three bacteria ( Escherichia coli, Staphylococcus aureus, Geobacillus stearothermophilus ), and the fungus Aspergillus niger . The impact of different application media was also evaluated. In parallel, decontaminated respirators were evaluated for filtration integrity and fit. Results: VHP resulted in > 2 log 10 inactivation of all tested biological indicators. The combination of UV-PX + moist heat resulted in > 2 log 10 inactivation of all biological indicators except G. stearothermohphilus . Greater than 95% filtration efficiency was maintained following 2 (UV-PX + <10% relative humidity heat) or 10 (VHP) cycles of treatment, and proper fit was also preserved. UV-PX + dry heat was insufficient to inactivate all biological indicators. Although very effective at virus decontamination, HPGP resulted in decreased filtration efficiency after 3 cycles, and EtO treatment raised potential toxicity concerns. The observed inactivation of viruses with UV-PX, heat, and hydrogen peroxide treatments varied as a function of which culture media (PBS buffer or DMEM) they were deposited in. Conclusions and Relevance: High levels of biological indicator inactivation were achieved following treatment with either moist heat or VHP. These same treatments did not significantly impact mask filtration or fit. Hospitals have a variety of scalable options to safely reprocess N95 masks. Beyond value in the current Covid-19 pandemic, the broad group of microorganisms and conditions tested make these results relevant in potential future pandemic scenarios.