Hongtong Li

Hongtong Li

Auto-generated profile, based on publicly available information

Hongtong Li

Tianjin Univ, State Key Lab Precis Measuring Technol & Instrumen, Tianjin 300072, Peoples R China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2022 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
HLHongtong Li
Hongtong Li
JKJiehu Kang
Jiehu Kang
LFLuyuan Feng
Luyuan Feng
JYJiantao Yue
Jiantao Yue
YHYibing Hou
Yibing Hou
WBWu Bin
Wu Bin

22 September 2023 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
HLHongtong Li
Hongtong Li
LFLuyuan Feng
Luyuan Feng
JKJiehu Kang
Jiehu Kang
JYJiantao Yue
Jiantao Yue
YHYibing Hou
Yibing Hou
WBWu Bin
Wu Bin
We propose a technique to achieve high-speed and high-precision distance measurement via phase demodulation of broadband optical carrier-based microwave interferometry (OCMI). An in-phase and quadrature (I/Q) processing scheme is designed and incorporated to measure the phase shift induced by target distance. The results could be efficiently derived from a minimum of one pair of detected outputs with immunity to power fluctuations. To extend the non-ambiguous measurement range while maintaining high resolution, a multifrequency-based phase unwrapping procedure is implemented. In the meantime, a driving module is utilized to effectively amplify and stabilize the signal. Experiments were carried out to evaluate the feasibility and performance of the proposed OCMI distance measurement method, which exhibits good accuracy, stability, and reliability. The maximum residual error is found to be 0.084 mm and the relative error is less than 2 × 10 −4 . Moreover, the method is capable to perform thousands of measurements within a few seconds, thus the OCMI-based dynamic target tracking has been achieved.

2 February 2024 in Optics & Laser Technology
Verified
Journal Article
Closed access
LFLuyuan Feng
Luyuan Feng
JKJiehu Kang
Jiehu Kang
LYLeiwen Yuan
Leiwen Yuan
HLHongtong Li
Hongtong Li
YCYifei Chen
Yifei Chen
BWBin Wu
Bin Wu

7 April 2023 in Optics Letters
Verified
Journal Article
Closed access
LFLuyuan Feng
Luyuan Feng
JKJiehu Kang
Jiehu Kang
HLHongtong Li
Hongtong Li
ZSZefeng Sun
Zefeng Sun
ZZZhen Zhang
Zhen Zhang
BWBin Wu
Bin Wu
The parameter calibration of a digital fringe projection profilometry (DFPP) system is a fundamental step and directly related to 3D measurement accuracy. However, existing solutions based on geometric calibration (GC) suffer from the weakness of limited operability and practicality. In this Letter, a novel, to the best of our knowledge, dual-sight fusion target is designed for flexible calibration. The novelty of this target is the ability to directly characterize control rays for ideal pixels of the projector, and to transform the rays into the camera coordinate system, which replaces the traditional phase-shifting algorithm and avoids the error from the nonlinear response of the system. Attributed to the excellent position resolution of a position-sensitive detector within the target, the geometric relationship between the projector and camera can be easily established by projecting only one diamond pattern. Experimental results demonstrated that the proposed method using only 20 captured images is capable of achieving comparable calibration accuracy to the traditional GC method (20 images versus 1080 images, 0.052 pixels versus 0.047 pixels), which is suitable for rapidly and accurately calibrating the DFPP system in the 3D shape measurement field.

29 September 2022 in Optics Communications
Verified
Journal Article
Closed access
HLHongtong Li
Hongtong Li
JKJiehu Kang
Jiehu Kang
LFLuyuan Feng
Luyuan Feng
JYJiantao Yue
Jiantao Yue
YHYibing Hou
Yibing Hou
WBWu Bin
Wu Bin

9 September 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HLHongtong Li
Hongtong Li
IIIvana Ivankovic
Ivana Ivankovic
JLJiao Li
Jiao Li
DRDaniel Razansky
Daniel Razansky
XDXose Luis Dean-Ben
Xose Luis Dean-Ben
Volumetric optoacoustic tomography has been shown to provide unprecedented capabilities for ultrafast imaging of cardiovascular dynamics in mice. Three-dimensional imaging rates in the order of 100 Hz have been achieved, which enabled the visualization of transient cardiac events such as arrhythmias or contrast agent perfusion without the need for retrospective gating. The fast murine heart rates (400–600 beats per minute) yet impose limitations when it comes to compounding of multiple frames or accurate registration of multi-spectral data. Herein, we investigate on the capabilities of Fourier analysis of four-dimensional data for coregistration of independent volumetric optoacoustic image sequences of the heart. The fundamental frequencies and higher harmonics of respiratory and cardiac cycles could clearly be distinguished, which facilitated efficient retrospective gating without additional readings. The performance of the suggested methodology was successfully demonstrated by compounding cardiac images acquired by raster-scanning of a spherical transducer array as well as by unmixing of oxygenated and deoxygenated hemoglobin from multi-spectral optoacoustic data.