12 May 2022 in Optics and Lasers in Engineering
22 September 2023 in Journal of Lightwave Technology
We propose a technique to achieve high-speed and high-precision distance measurement via phase demodulation of broadband optical carrier-based microwave interferometry (OCMI). An in-phase and quadrature (I/Q) processing scheme is designed and incorporated to measure the phase shift induced by target distance. The results could be efficiently derived from a minimum of one pair of detected outputs with immunity to power fluctuations. To extend the non-ambiguous measurement range while maintaining high resolution, a multifrequency-based phase unwrapping procedure is implemented. In the meantime, a driving module is utilized to effectively amplify and stabilize the signal. Experiments were carried out to evaluate the feasibility and performance of the proposed OCMI distance measurement method, which exhibits good accuracy, stability, and reliability. The maximum residual error is found to be 0.084 mm and the relative error is less than 2 × 10 −4 . Moreover, the method is capable to perform thousands of measurements within a few seconds, thus the OCMI-based dynamic target tracking has been achieved.
2 February 2024 in Optics & Laser Technology
7 April 2023 in Optics Letters
The parameter calibration of a digital fringe projection profilometry (DFPP) system is a fundamental step and directly related to 3D measurement accuracy. However, existing solutions based on geometric calibration (GC) suffer from the weakness of limited operability and practicality. In this Letter, a novel, to the best of our knowledge, dual-sight fusion target is designed for flexible calibration. The novelty of this target is the ability to directly characterize control rays for ideal pixels of the projector, and to transform the rays into the camera coordinate system, which replaces the traditional phase-shifting algorithm and avoids the error from the nonlinear response of the system. Attributed to the excellent position resolution of a position-sensitive detector within the target, the geometric relationship between the projector and camera can be easily established by projecting only one diamond pattern. Experimental results demonstrated that the proposed method using only 20 captured images is capable of achieving comparable calibration accuracy to the traditional GC method (20 images versus 1080 images, 0.052 pixels versus 0.047 pixels), which is suitable for rapidly and accurately calibrating the DFPP system in the 3D shape measurement field.
29 September 2022 in Optics Communications