Roman Steckiewicz

Roman Steckiewicz

Auto-generated profile, based on publicly available information

Roman Steckiewicz

Department of Cardiology, Central University Hospital in Warsaw, Poland

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 1997 in International Journal of Cardiology
Verified
Journal Article
Closed access
GOGrzegorz Opolski
Grzegorz Opolski
PŚPiotr Ścisło
Piotr Ścisło
JSJolanta Stanisławska
Jolanta Stanisławska
AGAleksander Górecki
Aleksander Górecki
RSRoman Steckiewicz
Roman Steckiewicz
Adam TorbickiAdam Torbicki
Adam Torbicki

12 February 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MMMichał Marchel
Michał Marchel
AMAgnieszka Madej-Pilarczyk
Agnieszka Madej-Pilarczyk
ATAgata Tymińska
Agata Tymińska
RSRoman Steckiewicz
Roman Steckiewicz
EOEwa Ostrowska
Ewa Ostrowska
GOGrzegorz Opolski
Grzegorz Opolski
Introduction: Cardiac involvement in patients with muscular dystrophy associated with Lamin A/C mutations (LMNA) is characterized by atrioventricular conduction abnormalities and life-threatening cardiac arrhythmias. Little is known about cardiac involvement in patients with emerin mutation (EMD). The aim of our study was to describe and compare the prevalence and time distribution of cardiac arrhythmias at extended follow-up. Patients and methods: 45 consecutive patients affected by muscular dystrophy associated to laminopathy or emerinopathy were examined. All patients underwent clinical evaluation, 12-lead surface electrocardiogram (ECG), 24 h electrocardiographic monitoring, and cardiac implanted device interrogation. Results: At the end of 11 (5.0–16.6) years of follow-up, 89% of the patients showed cardiac arrhythmias. The most prevalent was atrial standstill (AS) (31%), followed by atrial fibrillation/flutter (AF/Afl) (29%) and ventricular tachycardia (22%). EMD patients presented more frequently AF/AFl compared to LMNA (50% vs. 20%, p = 0.06). Half of the EMD patients presented with AS, whilst there was no occurrence of such in the LMNA (p = 0.001). Ventricular arrhythmias were found in 60% of patients with laminopathy compared to 3% in patients with emerinopathy (p < 0.001). The age of AVB occurrence was higher in the LMNA group (32.8 +/− 10.6 vs. 25.1 +/− 9.1, p = 0.03). Conclusions: Atrial arrhythmias are common findings in patients with muscular dystrophy associated with EMD/LMNA mutations; however, they occurred earlier in EMD patients. Ventricular arrhythmias were very common (60%) in LMNA and occurred definitely earlier compared to the EMD group.

15 June 2016 in Polish Heart Journal
Verified
Journal Article
Closed access
RSRoman Steckiewicz
Roman Steckiewicz
PSPrzemysław Stolarz
Przemysław Stolarz
EŚElżbieta Świętoń
Elżbieta Świętoń
AMAgnieszka Madej-Pilarczyk
Agnieszka Madej-Pilarczyk
MGMarcin Grabowski
Marcin Grabowski
GOGrzegorz Opolski
Grzegorz Opolski
Emery-Dreifuss muscular dystrophy (EDMD) is a genetic condition associated with cardiac arrhythmias. The patients typically develop early, asymptomatic bradyarrhythmia, which may lead to sudden death, preventable with a cardiac implantable electronic device (CIED). EDMD may be characterised by atrial electrical silence. Intra-operative electrophysiological evaluation of the myocardium helps ultimately determine the true nature of the disorder and select an appropriate CIED. To analyse permanent electrotherapy procedures in EDMD patients: atrial pacing limitations that stem from the electrophysiological properties of the myocardium and long-term follow-up of implanted devices. A total of 21 EDMD patients (mean age 29 ± 9 years) with a CIED implanted (1976-2014) due to bradyarrhythmia were included in the study. The implantation procedures and factors determining the CIED type selection were analysed. CIEDs were implanted in five women and in 16 men with EDMD types 1 and 2 (mean follow-up: 11 ± 8 years). Intra-operatively assessed atrial electrophysiology resulted in changing the planned CIED type during the procedure in three men with EDMD type 1. Eventually, we implanted: eight DDD, one VDD, 11 VVI, and one CD-DR device, with four of the patients' devices switched later from DDD to VVI mode in response to electrophysiological changes in the atria. Intra-operative assessment of atrial electrophysiological properties resulted in changing the planned DDD mode for VVI in 19% of patients with EDMD type 1. Progression of the underlying disease over a 39-year follow-up resulted in a later change of the initially selected pacing mode from DDD to VVI in 40% of cases.

1 December 2017 in Folia Morphologica
Verified
Journal Article
Closed access
PDF file
RSR. Steckiewicz
R. Steckiewicz
EŚE. B. Świętoń
E. B. Świętoń
AKA. Kołodzińska
A. Kołodzińska
MBM. Bogdańska
M. Bogdańska
ŁFŁ. Fus
Ł. Fus
PSP. Solarz
P. Solarz
Background: The final stage of a conventional de-novo cardiac implantable electronic device (CIED) implantation procedure with transvenous lead insertion involves the formation of a pocket by tissue separation superficial to the pectoralis major muscle in the right or left infraclavicular region, where the device is subsequently placed. Over time, a scar “capsule” is formed around the CIED as a result of normal biological remodelling. Materials and methods: The purpose of this study was to analyse the structure and present the variations of CIED capsules observed during device replacement. The nature and extent of this local tissue remodelling, which had occurred from the time of device implantation to its replacement in 2016 (10 ± 3.1 years), was analysed in 100 patients (mean age 77.1 ± 14.5 years), including 45 women and 55 men. Results: The most prevalent types of “capsules” (70% of cases) were those with similar thickness of both walls or a slightly thicker posterior (< 1.0 mm) than anterior wall (< 0.5 mm). The second most common capsule type (23% of cases) was characterised by a significantly thicker posterior wall of scar tissue (> 1.0 mm). The third group of capsules was characterised by various degrees of wall calcification (7% of cases). Conclusions: The extent and nature of scar tissue structure in the CIED pocket walls seem to correlate with the relative position of cardiac lead loops with respect to the device itself; where the more extensive scarring is likely to result from pocket wall irritation in the capsule formation phase due to lead movements underneath the device. The group of cases with calcified capsules was characterised by “old” device pockets (> 13 years) and the oldest population (patients in their 80s and 90s). Background: The final stage of a conventional de-novo cardiac implantable electronic device (CIED) implantation procedure with transvenous lead insertion involves the formation of a pocket by tissue separation superficial to the pectoralis major muscle in the right or left infraclavicular region, where the device is subsequently placed. Over time, a scar “capsule” is formed around the CIED as a result of normal biological remodelling. Materials and methods: The purpose of this study was to analyse the structure and present the variations of CIED capsules observed during device replacement. The nature and extent of this local tissue remodelling, which had occurred from the time of device implantation to its replacement in 2016 (10 ± 3.1 years), was analysed in 100 patients (mean age 77.1 ± 14.5 years), including 45 women and 55 men. Results: The most prevalent types of “capsules” (70% of cases) were those with similar thickness of both walls or a slightly thicker posterior (< 1.0 mm) than anterior wall (< 0.5 mm). The second most common capsule type (23% of cases) was characterised by a significantly thicker posterior wall of scar tissue (> 1.0 mm). The third group of capsules was characterised by various degrees of wall calcification (7% of cases). Conclusions: The extent and nature of scar tissue structure in the CIED pocket walls seem to correlate with the relative position of cardiac lead loops with respect to the device itself; where the more extensive scarring is likely to result from pocket wall irritation in the capsule formation phase due to lead movements underneath the device. The group of cases with calcified capsules was characterised by “old” device pockets (> 13 years) and the oldest population (patients in their 80s and 90s).

1 March 2016 in Hellenic Journal of Cardiology
Verified
Journal Article
Open access
RSRoman Steckiewicz
Roman Steckiewicz
DKDariusz A. Kosior
Dariusz A. Kosior
MRMarek Rosiak
Marek Rosiak
EŚElżbieta Świętoń
Elżbieta Świętoń
PSPrzemysław Stolarz
Przemysław Stolarz
MGMarcin Grabowski
Marcin Grabowski
The vast majority of cardiac implantable electronic device (CIED) recipients require transvenous lead insertion, which may be hindered by the presence of venous anomalies. The aim of this study was to determine the prevalence and variations of persistent left superior vena cava (PLSVC) and to conduct subsequent outpatient follow-up in terms of device function and the clinical condition of the recipients using data from CIED placement procedures conducted over a 12-year period. The study population included patients undergoing first-time transvenous implantation of cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). The presence of PLSVC was determined based on intra-procedure venography. Outpatient follow-up involved assessments of patient condition, radiological imaging, and CIED function. Of a total of 4708 CIED recipients, PLSVC was detected in eight patients (mean age 65.5±13.9); five of them had double superior vena cava (DSVC), including three cases in which the vessels were bridged with a brachiocephalic vein (BCV). Three patients presented PLSVC associated with the absence of the right superior vena cava (RSVC), a very rare anomaly. Seven patients remain under observation, for a total of 78.4±48.4 months of follow-up. The rate of venous anomalies in the form of PLSVC detected in the evaluated population was 0.17%. These PLSVC cases were asymptomatic, which hindered their earlier detection. The presence of these anomalies made the procedures more challenging for the operator and increased the perioperative complication rates; however, neither patient condition nor CIED function was affected based on the long-term outpatient follow-up.

31 August 2016 in Folia Morphologica
Verified
Journal Article
Open access
PDF file
EŚE. B. Świętoń
E. B. Świętoń
RSR. Steckiewicz
R. Steckiewicz
MGM. Grabowski
M. Grabowski
PSP. Stolarz
P. Stolarz
Background: Supraclavicular variations of the cephalic vein (CV) are detected sporadically. A somewhat more common finding is a CV variation with the typical course of the main vessel but with an additional supraclavicular branch, called the jugulocephalic vein (JCV). The aim of the study was to detect supraclavicular CVs or JCVs via intra-operative venography as well as assess their effects on primary and later revision cardiac implantable electronic device (CIED) procedures in our patients. Materials and methods: We analysed venographic images obtained during CIED procedures at our centre between 2011 and 2015. Out of the 324 venographies conducted during first-time CIED implantation, we identified 14 showing either a supraclavicular course of the CV itself or a persistent JCV. Among revision procedure venographies, we identified 1 case of pertinent CV variations. These vessels had been morphometrically altered by previous medical interventions. Results: Based on topography and morphometric parameters, we identified three anatomical variations of supraclavicular vessels: 2 cases of a supraclavicular CV and 12 cases of an infraclavicular CV accompanied by a persistent supraclavicular JCV (with the diameter larger than that of the main CV in 5 cases and smaller in 7 cases). In 2 cases the enlarged diameter of the JCV was probably due to increased collateral venous flow resulting from thrombotic lesions in the subclavian vein. Conclusions: Supraclavicular CV variations are rare. Nonetheless, they may significantly affect both first-time and later revision CIED procedures. The presence of a supraclavicular vein is an indication for diagnostic venography in the area of the clavipectoral triangle before the CIED procedure. Background: Supraclavicular variations of the cephalic vein (CV) are detected sporadically. A somewhat more common finding is a CV variation with the typical course of the main vessel but with an additional supraclavicular branch, called the jugulocephalic vein (JCV). The aim of the study was to detect supraclavicular CVs or JCVs via intra-operative venography as well as assess their effects on primary and later revision cardiac implantable electronic device (CIED) procedures in our patients. Materials and methods: We analysed venographic images obtained during CIED procedures at our centre between 2011 and 2015. Out of the 324 venographies conducted during first-time CIED implantation, we identified 14 showing either a supraclavicular course of the CV itself or a persistent JCV. Among revision procedure venographies, we identified 1 case of pertinent CV variations. These vessels had been morphometrically altered by previous medical interventions. Results: Based on topography and morphometric parameters, we identified three anatomical variations of supraclavicular vessels: 2 cases of a supraclavicular CV and 12 cases of an infraclavicular CV accompanied by a persistent supraclavicular JCV (with the diameter larger than that of the main CV in 5 cases and smaller in 7 cases). In 2 cases the enlarged diameter of the JCV was probably due to increased collateral venous flow resulting from thrombotic lesions in the subclavian vein. Conclusions: Supraclavicular CV variations are rare. Nonetheless, they may significantly affect both first-time and later revision CIED procedures. The presence of a supraclavicular vein is an indication for diagnostic venography in the area of the clavipectoral triangle before the CIED procedure.