1 April 2001 in International Journal of Cardiology
1 February 2007 in International Journal of Cardiology
15 June 2016 in Polish Heart Journal
AMAgnieszka Madej-Pilarczyk
Agnieszka Madej-Pilarczyk
+4
Emery-Dreifuss muscular dystrophy (EDMD) is a genetic condition associated with cardiac arrhythmias. The patients typically develop early, asymptomatic bradyarrhythmia, which may lead to sudden death, preventable with a cardiac implantable electronic device (CIED). EDMD may be characterised by atrial electrical silence. Intra-operative electrophysiological evaluation of the myocardium helps ultimately determine the true nature of the disorder and select an appropriate CIED. To analyse permanent electrotherapy procedures in EDMD patients: atrial pacing limitations that stem from the electrophysiological properties of the myocardium and long-term follow-up of implanted devices. A total of 21 EDMD patients (mean age 29 ± 9 years) with a CIED implanted (1976-2014) due to bradyarrhythmia were included in the study. The implantation procedures and factors determining the CIED type selection were analysed. CIEDs were implanted in five women and in 16 men with EDMD types 1 and 2 (mean follow-up: 11 ± 8 years). Intra-operatively assessed atrial electrophysiology resulted in changing the planned CIED type during the procedure in three men with EDMD type 1. Eventually, we implanted: eight DDD, one VDD, 11 VVI, and one CD-DR device, with four of the patients' devices switched later from DDD to VVI mode in response to electrophysiological changes in the atria. Intra-operative assessment of atrial electrophysiological properties resulted in changing the planned DDD mode for VVI in 19% of patients with EDMD type 1. Progression of the underlying disease over a 39-year follow-up resulted in a later change of the initially selected pacing mode from DDD to VVI in 40% of cases.
21 October 2005 in European Heart Journal
GHGrzegorz J. Horszczaruk
+2
A 66-year-old woman was admitted after an episode of faint with concomitant severe chest pain lasting ∼2 h. Typical retrosternal localization of the pain with ST-elevation (Pardee wave) in leads II, III, and aVF, and ST-depression in I, V1–V3 allowed to diagnose acute infero-posterior myocardial infarction. ECG also revealed temporal second-degree atrioventricular block (Mobitz II). Blood pressure was 140/70 mmHg and HR was 55 b.p.m. No distinct murmur was heard on cardiac auscultation. In coronary angiography, left coronary artery had no significant stenoses. After placing the catheter in the ostium of RCA, no severe stenosis was seen and the flow was normal (TIMI 3, MBG 3). Just after selective cannulation of the RCA, chest pain diminished and ST-elevation recovered. Of note, during the peak of dye injection, the lumen was distended and collapsed at the end of the injection in the proximal segment of the artery. However, in coronary angiography, the lumen of RCA seemed not to be narrowed significantly (Panel A). To thoroughly assess the vessel, intracoronary ultrasound (ICUS) was performed. No evident atheromatous plaque was present in proximal part of RCA. During manual pullback, a hypoechoic mass adjacent to proximal segment of the artery was clearly seen (Panel B). The lumen in proximal segment and in ostium of RCA was impressed and narrowed by that mass (Panel C). Such hypoechoic mass parallel to the artery is not normally seen at this site. It was suspected that false channel existed and was propagated from the aorta to the proximal part of RCA. Therefore, dissecting aneurysm of the aorta was strongly suspected. It is important that almost immediately after withdrawal of a catheter from the ostium of RCA, the signs of acute myocardial ischaemia (i.e. severe chest pain and ST-elevation) relapsed. We thought that the catheter kept the lumen of RCA patent enabling restoration flow through the artery. Computed tomography (CT) fully confirmed our diagnosis of dissecting aneurysm—revealing long dissection extending from aortic valve up to the renal arteries with false lumen being partly thrombosed. CT showed patent left coronary artery and lack of patency of the RCA (Panel D).
1 March 2016 in Hellenic Journal of Cardiology
The vast majority of cardiac implantable electronic device (CIED) recipients require transvenous lead insertion, which may be hindered by the presence of venous anomalies. The aim of this study was to determine the prevalence and variations of persistent left superior vena cava (PLSVC) and to conduct subsequent outpatient follow-up in terms of device function and the clinical condition of the recipients using data from CIED placement procedures conducted over a 12-year period. The study population included patients undergoing first-time transvenous implantation of cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). The presence of PLSVC was determined based on intra-procedure venography. Outpatient follow-up involved assessments of patient condition, radiological imaging, and CIED function. Of a total of 4708 CIED recipients, PLSVC was detected in eight patients (mean age 65.5±13.9); five of them had double superior vena cava (DSVC), including three cases in which the vessels were bridged with a brachiocephalic vein (BCV). Three patients presented PLSVC associated with the absence of the right superior vena cava (RSVC), a very rare anomaly. Seven patients remain under observation, for a total of 78.4±48.4 months of follow-up. The rate of venous anomalies in the form of PLSVC detected in the evaluated population was 0.17%. These PLSVC cases were asymptomatic, which hindered their earlier detection. The presence of these anomalies made the procedures more challenging for the operator and increased the perioperative complication rates; however, neither patient condition nor CIED function was affected based on the long-term outpatient follow-up.
31 August 2016 in Folia Morphologica
Background: Supraclavicular variations of the cephalic vein (CV) are detected sporadically. A somewhat more common finding is a CV variation with the typical course of the main vessel but with an additional supraclavicular branch, called the jugulocephalic vein (JCV). The aim of the study was to detect supraclavicular CVs or JCVs via intra-operative venography as well as assess their effects on primary and later revision cardiac implantable electronic device (CIED) procedures in our patients. Materials and methods: We analysed venographic images obtained during CIED procedures at our centre between 2011 and 2015. Out of the 324 venographies conducted during first-time CIED implantation, we identified 14 showing either a supraclavicular course of the CV itself or a persistent JCV. Among revision procedure venographies, we identified 1 case of pertinent CV variations. These vessels had been morphometrically altered by previous medical interventions. Results: Based on topography and morphometric parameters, we identified three anatomical variations of supraclavicular vessels: 2 cases of a supraclavicular CV and 12 cases of an infraclavicular CV accompanied by a persistent supraclavicular JCV (with the diameter larger than that of the main CV in 5 cases and smaller in 7 cases). In 2 cases the enlarged diameter of the JCV was probably due to increased collateral venous flow resulting from thrombotic lesions in the subclavian vein. Conclusions: Supraclavicular CV variations are rare. Nonetheless, they may significantly affect both first-time and later revision CIED procedures. The presence of a supraclavicular vein is an indication for diagnostic venography in the area of the clavipectoral triangle before the CIED procedure. Background: Supraclavicular variations of the cephalic vein (CV) are detected sporadically. A somewhat more common finding is a CV variation with the typical course of the main vessel but with an additional supraclavicular branch, called the jugulocephalic vein (JCV). The aim of the study was to detect supraclavicular CVs or JCVs via intra-operative venography as well as assess their effects on primary and later revision cardiac implantable electronic device (CIED) procedures in our patients. Materials and methods: We analysed venographic images obtained during CIED procedures at our centre between 2011 and 2015. Out of the 324 venographies conducted during first-time CIED implantation, we identified 14 showing either a supraclavicular course of the CV itself or a persistent JCV. Among revision procedure venographies, we identified 1 case of pertinent CV variations. These vessels had been morphometrically altered by previous medical interventions. Results: Based on topography and morphometric parameters, we identified three anatomical variations of supraclavicular vessels: 2 cases of a supraclavicular CV and 12 cases of an infraclavicular CV accompanied by a persistent supraclavicular JCV (with the diameter larger than that of the main CV in 5 cases and smaller in 7 cases). In 2 cases the enlarged diameter of the JCV was probably due to increased collateral venous flow resulting from thrombotic lesions in the subclavian vein. Conclusions: Supraclavicular CV variations are rare. Nonetheless, they may significantly affect both first-time and later revision CIED procedures. The presence of a supraclavicular vein is an indication for diagnostic venography in the area of the clavipectoral triangle before the CIED procedure.