T. Slendebroek

T. Slendebroek

Auto-generated profile, based on publicly available information

T. Slendebroek

Center for Energy Research, University of California, San Diego, La Jolla, CA 92093-0417, United States of America

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
BLB. C. Lyons
B. C. Lyons
JMJ. McClenaghan
J. McClenaghan
TST. Slendebroek
T. Slendebroek
OMO. Meneghini
O. Meneghini
Tom F. NeiserTom F. Neiser
Tom F. Neiser
ATA. D. Turnbull
A. D. Turnbull
The STEP (Stability, Transport, Equilibrium, and Pedestal) integrated-modeling tool has been developed in OMFIT to predict stable, tokamak equilibria self-consistently with core-transport and pedestal calculations. STEP couples theory-based codes to integrate a variety of physics, including magnetohydrodynamic stability, transport, equilibrium, pedestal formation, and current-drive, heating, and fueling. The input/output of each code is interfaced with a centralized ITER-Integrated Modelling & Analysis Suite data structure, allowing codes to be run in any order and enabling open-loop, feedback, and optimization workflows. This paradigm simplifies the integration of new codes, making STEP highly extensible. STEP has been verified against a published benchmark of six different integrated models. Core-pedestal calculations with STEP have been successfully validated against individual DIII-D H-mode discharges and across more than 500 discharges of the H98,y2 database, with a mean error in confinement time from experiment less than 19%. STEP has also reproduced results in less conventional DIII-D scenarios, including negative-central-shear and negative-triangularity plasmas. Predictive STEP modeling has been used to assess performance in several tokamak reactors. Simulations of a high-field, large-aspect-ratio reactor show significantly lower fusion power than predicted by a zero-dimensional study, demonstrating the limitations of scaling-law extrapolations. STEP predictions have found promising scenarios for an EXhaust and Confinement Integration Tokamak Experiment, including a high-pressure, 80%-bootstrap-fraction plasma. ITER modeling with STEP has shown that pellet fueling enhances fusion gain in both the baseline and advanced-inductive scenarios. Finally, STEP predictions for the SPARC baseline scenario are in good agreement with published results from the physics basis.

1 July 2023 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
TST. Slendebroek
T. Slendebroek
JMJ. McClenaghan
J. McClenaghan
OMO. M. Meneghini
O. M. Meneghini
BLB. C. Lyons
B. C. Lyons
SSS. P. Smith
S. P. Smith
JCJ. Candy
J. Candy
We have developed an innovative workflow, Stability, Transport, Equilibrium, and Pedestal (STEP)-zero-dimensional (0D), within the OMFIT integrated modeling framework. Through systematic validation against the International Tokamak Physics Activity global H-mode confinement database, we demonstrated that STEP-0D, on average, predicts the energy confinement time with a mean relative error of less than 19%. Moreover, this workflow showed promising potential in predicting plasmas for proposed fusion reactors such as the affordable, robust, compact (ARC) reactor, the European demonstration power plant (EU-DEMO), and the China fusion engineering test reactor (CFETR) indicating moderate H-factors between 0.9 and 1.2. STEP-0D allows theory-based prediction of tokamak scenarios, beginning with 0D quantities. The workflow initiates with the PRO-create module, generating physically consistent plasma profiles and equilibrium using the same 0D quantities as the IPB98(y,2) confinement scaling. This sets the starting point for the STEP module, which further iterates between theory-based physics models of equilibrium, core transport, and pedestal to yield a self-consistent solution. Given these attributes, STEP-0D not only improves the accuracy of predicting plasma performance but also provides a path toward a novel fusion power plant design workflow. When integrated with engineering and costing models within an optimization, this new approach could eliminate the iterative reconciliation between plasma models of varying fidelity. This potential for a more efficient design process underpins STEP-0D's significant contribution to future fusion power plant development.

1 April 2023 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
JMJ. McClenaghan
J. McClenaghan
TST. Slendebroek
T. Slendebroek
GSG. M. Staebler
G. M. Staebler
SSS. P. Smith
S. P. Smith
OMO. M. Meneghini
O. M. Meneghini
WGW. Guttenfelder
W. Guttenfelder
Investigation of linear gyrokinetic ion-scale modes ( k θ ρ s = 0.3) finds that a transition from ion temperature gradient to microtearing mode (MTM) dominance occurs as the density is increased near the pedestal region of a parameterized DIII-D sized tokamak. H-modes profile densities, temperatures, and equilibria are parameterized utilizing the OMFIT PRO_create module. With these profiles, linear gyrokinetic ion-scale instabilities are predicted with CGYRO. This transition (nMTM) has a weak dependence on radial location in the region near the top of the pedestal ( ρ = 0.7 − 0.9), which allows simulating single radii to examine the approximate scaling of nMTM with global parameters. The critical nMTM is found to scale with plasma current. Additionally, increasing the minor radius by decreasing the aspect ratio and increasing the major radius are found to reduce nMTM. However, any relationship between nMTM and density limit physics remains unclear as nMTM increases relative to the Greenwald density with larger minor radius and with larger magnetic field, suggesting that the transport due to MTM may be less important for a reactor. Additionally, nMTM is sensitive to the pedestal temperature, the local electron and ion gradients, the ratio of ion to electron temperature T i / T e, and the current profile. MTMs are predicted to be the dominant instability in the core at similar Greenwald fractions for DIII-D, NSTX, and NSTX-U H-mode experiments, supporting the results of the parameterized study. Additionally, MTMs continue to be the dominant linear instability in a DIII-D L-mode after an H–L transition as the plasma approaches a density limit disruption despite the large change in plasma profiles.

13 January 2026 in Nuclear Fusion
Verified
Journal Article
Open access
TST. Slendebroek
T. Slendebroek
ANA.O. Nelson
A.O. Nelson
OMO.M. Meneghini
O.M. Meneghini
GDGiacomo Dose
Giacomo Dose
AGA.G. Ghiozzi
A.G. Ghiozzi
CHChristopher Holland
Christopher Holland
The optimal configuration choice between positive triangularity (PT) and negative triangularity (NT) tokamaks for fusion power plants hinges on navigating different operational constraints rather than achieving specific plasma performance metrics. This study presents a systematic comparison using constrained multi-objective optimization with the integrated FUsion Synthesis Engine (FUSE) framework. Over 200 000 integrated design evaluations were performed exploring the trade-offs between capital cost minimization and operational reliability (maximizing q 95 ) while satisfying engineering constraints including 250 ± 50 MW net electric power, tritium breeding ratio > 1.1, power exhaust limits and an hour flattop time. Both configurations achieve similar cost-performance Pareto fronts through contrasting design philosophies. PT, while demonstrating resilience to pedestal degradation (compensating for up to 40% reduction), are constrained to larger machines ( R 0 > 6.5 m) by the narrow operational window between L–H threshold requirements and the research-established power exhaust limit ( P sol / R < 15 MW m −1 ). This forces optimization through comparatively reduced magnetic field (∼8 T). NT configurations exploit their freedom from these constraints to access compact, high-field designs ( R 0 ∼ 5.5 m, B 0 > 12 T), creating natural synergy with advancing HTS technology. Sensitivity analyses reveal that PT’s economic viability depends critically on uncertainties in L–H threshold scaling and power handling limits. Notably, a 50% variation in either could eliminate viable designs or enable access to the compact design space. These results suggest configuration selection should be risk-informed: PT offers the lowest-cost path when operational constraints can be confidently predicted, while NT is robust to large variations in constraints and physics uncertainties.

22 April 2025 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
SDS S Denk
S S Denk
TAT B Amara
T B Amara
TOT Odstrčil
T Odstrčil
LSL Stagner
L Stagner
CAC Akcay
C Akcay
RNR Nazikian
R Nazikian
Accurate plasma state reconstruction will be crucial for the success of ITER and future fusion plants, but the harsh conditions of a burning plasma will make diagnostic operation more challenging than in current machines. Integrated data analysis (IDA) based on Bayesian inference allows for improved information gain by combining the analysis of many diagnostics into a single step using sophisticated forward models. It also provides a framework to seamlessly combine predictive modeling and data, which can be invaluable in a data-poor environment. As a step towards IDA at scale, we present a new, fast integrated analysis framework that allows for the simultaneous reconstruction of the kinetic profiles and the magnetic equilibrium with uncertainties included. This analysis framework allows for the systematic evaluation of models using extensive experimental data leveraging DOE supercomputing infrastructure, such as being developed through the DOE-Advanced Scientific Computing Research integrated research infrastructure (Smith, XLOOP). To test the performance and verify the code it was applied to an ITER-like scenario using a realistic machine geometry and diagnostic description. Using artificial data for magnetics, Thomson scattering, interferometry, and polarimetry generated from a known ground truth, the coupled equilibrium and kinetic profile reconstruction problem was solved via the Maximum a posteriori method in approximately three minutes on a multicore CPU including uncertainty quantification. The resulting equilibrium and kinetic profiles were found to be in reasonable agreement with the ground truth.

1 September 2026 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Open access
PDF file
SFS Freiberger
S Freiberger
EBE M Bursch
E M Bursch
JCJ Chiriboga
J Chiriboga
HFH J Farre-Kaga
H J Farre-Kaga
EFE Felske
E Felske
CPC Paz-Soldan
C Paz-Soldan
This work presents the compact experimental negative triangularity (NT) reactor (CENTAUR), a low overnight cost, high-field tokamak, breakeven reactor design, achieving a predicted total fusion power of 40 MW and scientific energy gain of 1.3. Ballooning stability calculations confirm that the device’s pedestal is within the first stability regime, which is consistent with the expected ELM-free operation associated with NT plasmas. The geometry of the NT divertor allows for high fraction of radiated power (13.5 % ) between the separatrix and plasma facing components. Heat transport modeling based on simulations of the edge region show heat loads into plasma facing components well below material limits. The magnet system employs rare-earth barium copper oxide high-temperature superconductors in 18 toroidal field coils, an hourglass-shaped central solenoid, and six poloidal field coils to support high-field ( B 0 = 10.9 T) plasma confinement, shaping, and current drive. Neutronics analysis shows that a 12 cm B 4 C shield keeps superconducting magnet heating below the 33 K quench limit during 10 s, 40 MW DT pulses. With this shielding, the modeled fluence indicates HTS components can survive more than ten times the 3000-pulse design lifetime. Iteration of economic analysis in tandem with the technical design process allows CENTAUR to achieve its overnight cost goal of $2 billion US determined using a custom costing model that predicts a total overnight cost of 1.6 B ± 0.2 B US.