Felix K. Kopp

Felix K. Kopp

Auto-generated profile, based on publicly available information

Felix K. Kopp

Technische Universitat Munchen, Munchen, 80333, GERMANY

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
NSNadav Shapira
Nadav Shapira
JFJulia Fokuhl
Julia Fokuhl
MSManuel Schultheiß
Manuel Schultheiß
SBStefanie Beck
Stefanie Beck
FKFelix K Kopp
Felix K Kopp
PNPeter B Noël
Peter B Noël
Purpose: To evaluate the benefit of the additional available information present in spectral CT datasets, as compared to conventional CT datasets, when utilizing convolutional neural networks for fully automatic localisation and classification of liver lesions in CT images. Materials and Methods: Conventional and spectral CT images (iodine maps, virtual monochromatic images (VMI)) were obtained from a spectral dual-layer CT system. Patient diagnosis were known from the clinical reports and classified into healthy, cyst and hypodense metastasis. In order to compare the value of spectral versus conventional datasets when being passed as input to machine learning algorithms, we implemented a weakly-supervised convolutional neural network (CNN) that learns liver lesion localisation without pixel-level ground truth annotations. Regions-of-interest are selected automatically based on the localisation results and are used to train a second CNN for liver lesion classification (healthy, cyst, hypodense metastasis). The accuracy of lesion localisation was evaluated using the Euclidian distances between the ground truth centres of mass and the predicted centres of mass. Lesion classification was evaluated by precision, recall, accuracy and F1-Score. Results: Lesion localisation showed the best results for spectral information with distances of 8.22 ± 10.72 mm, 8.78 ± 15.21 mm and 8.29 ± 12.97 mm for iodine maps, 40 keV and 70 keV VMIs, respectively. With conventional data distances of 10.58 ± 17.65 mm were measured. For lesion classification, the 40 keV VMIs achieved the highest overall accuracy of 0.899 compared to 0.854 for conventional data. Conclusion: An enhanced localisation and classification is reported for spectral CT data, which demonstrates that combining machine-learning technology with spectral CT information may in the future improve the clinical workflow as well as the diagnostic accuracy.

18 March 2015
Verified
Conference Paper
Open access
PDF file
RNRadin A. Nasirudin
Radin A. Nasirudin
RTRie Tachibana
Rie Tachibana
JNJanne J. Näppi
Janne J. Näppi
KMKai Mei
Kai Mei
FKFelix K. Kopp
Felix K. Kopp
PNPeter B. Noël
Peter B. Noël
In recent years, dual-energy computed tomography (DECT) has been widely used in the clinical routine due to improved diagnostics capability from additional spectral information. One promising application for DECT is CT colonography (CTC) in combination with computer-aided diagnosis (CAD) for detection of lesions and polyps. While CAD has demonstrated in the past that it is able to detect small polyps, its performance is highly dependent on the quality of the input data. The presence of artifacts such as beam-hardening and noise in ultra-low-dose CTC may severely degrade detection performances of small polyps. In this work, we investigate and compare virtual monochromatic images, generated by image-based decomposition and projection-based decomposition, with respect to CAD performance. In the image-based method, reconstructed images are firstly decomposed into water and iodine before the virtual monochromatic images are calculated. On the contrary, in the projection-based method, the projection data are first decomposed before calculation of virtual monochromatic projection and reconstruction. Both material decomposition methods are evaluated with regards to the accuracy of iodine detection. Further, the performance of the virtual monochromatic images is qualitatively and quantitatively assessed. Preliminary results show that the projection-based method does not only have a more accurate detection of iodine, but also delivers virtual monochromatic images with reduced beam hardening artifacts in comparison with the image-based method. With regards to the CAD performance, the projection-based method yields an improved detection performance of polyps in comparison with that of the image-based method.