Kai Mei

Kai Mei

Auto-generated profile, based on publicly available information

Kai Mei

University of Pennsylvania

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2021 in Medical Physics
Verified
Journal Article
Closed access
PDF file
KMKai Mei
Kai Mei
MGMichael Geagan
Michael Geagan
LRLeonid Roshkovan
Leonid Roshkovan
HLHarold I. Litt
Harold I. Litt
GGGrace J. Gang
Grace J. Gang
PNPeter B. Noël
Peter B. Noël

21 June 2017 in European Radiology
Verified
Journal Article
Open access
PDF file
KMKai Mei
Kai Mei
FKFelix K. Kopp
Felix K. Kopp
RBRolf Bippus
Rolf Bippus
TKThomas Köhler
Thomas Köhler
BSBenedikt J. Schwaiger
Benedikt J. Schwaiger
TBThomas Baum
Thomas Baum
Objective Osteoporosis diagnosis using multidetector CT (MDCT) is limited to relatively high radiation exposure. We investigated the effect of simulated ultra-low-dose protocols on in-vivo bone mineral density (BMD) and quantitative trabecular bone assessment. Materials and methods Institutional review board approval was obtained. Twelve subjects with osteoporotic vertebral fractures and 12 age- and gender-matched controls undergoing routine thoracic and abdominal MDCT were included (average effective dose: 10 mSv). Ultra-low radiation examinations were achieved by simulating lower tube currents and sparse samplings at 50%, 25% and 10% of the original dose. BMD and trabecular bone parameters were extracted in T10–L5. Results Except for BMD measurements in sparse sampling data, absolute values of all parameters derived from ultra-low-dose data were significantly different from those derived from original dose images (p<0.05). BMD, apparent bone fraction and trabecular thickness were still consistently lower in subjects with than in those without fractures (p<0.05). Conclusion In ultra-low-dose scans, BMD and microstructure parameters were able to differentiate subjects with and without vertebral fractures, suggesting osteoporosis diagnosis is feasible. However, absolute values differed from original values. BMD from sparse sampling appeared to be more robust. This dose-dependency of parameters should be considered for future clinical use. Key Points • BMD and quantitative bone parameters are assessable in ultra-low-dose in vivo MDCT scans. • Bone mineral density does not change significantly when sparse sampling is applied. • Quantitative trabecular bone microstructure measurements are sensitive to dose reduction. • Osteoporosis subjects could be differentiated even at 10% of original dose. • Radiation exposure should be considered when comparing quantitative bone parameters.

22 August 2018 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
KMKai Mei
Kai Mei
SESebastian Ehn
Sebastian Ehn
MOMarkus Oechsner
Markus Oechsner
FKFelix K. Kopp
Felix K. Kopp
DPDaniela Pfeiffer
Daniela Pfeiffer
PNPeter B. Noël
Peter B. Noël
X-ray and particle radiation therapy planning requires accurate estimation of local electron density within the patient body to calculate dose delivery to tumour regions. We evaluate the feasibility and accuracy of electron density measurement using dual-layer computed tomography (DLCT), a recently introduced dual-energy CT technique. Two calibration phantoms were scanned with DLCT and virtual monoenergetic images (VMIs) at 50 keV and 200 keV were generated. We investigated two approaches to obtain relative electron densities from these VMIs: to fit an analytic interaction cross-sectional model and to empirically calibrate a conversion function with one of the phantoms. Knowledge of the emitted x-ray spectrum was not required for the presented work. The results from both methods were highly correlated to the nominal values (R > 0.999). Except for the water and lung inserts, the error was within 1.79% (average 1.53%) for the cross-sectional model and 1.61% (average 0.87%) for the calibrated conversion. Different radiation doses did not have a significant influence on the measurement (p = 0.348, 0.167), suggesting that the methods are reproducible. Further, we applied these methods to routine clinical data. Our study shows a high validity of electron density estimation based on DLCT, which has potential to improve the procedure and accuracy of measuring electron density in clinical practice.

15 October 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KMKai Mei
Kai Mei
PPPouyan Pasyar
Pouyan Pasyar
MGMichael Geagan
Michael Geagan
LLLeening P. Liu
Leening P. Liu
NSNadav Shapira
Nadav Shapira
PNPeter B. Noël
Peter B. Noël
The objective of this study is to create patient-specific phantoms for computed tomography (CT) that possess accurate densities and exhibit visually realistic image textures. These qualities are crucial for evaluating CT performance in clinical settings. The study builds upon a previously presented 3D printing method (PixelPrint) by incorporating soft tissue and bone structures. We converted patient DICOM images directly into 3D printer instructions using PixelPrint and utilized calcium-doped filament to increase the Hounsfield unit (HU) range. Density was modeled by controlling printing speed according to volumetric filament ratio to emulate attenuation profiles. We designed micro-CT phantoms to demonstrate the reproducibility, and to determine mapping between filament ratios and HU values on clinical CT systems. Patient phantoms based on clinical cervical spine and knee examinations were manufactured and scanned with a clinical spectral CT scanner. The CT images of the patient-based phantom closely resembled original CT images in visual texture and contrast. Micro-CT analysis revealed minimal variations between prints, with an overall deviation of ± 0.8% in filament line spacing and ± 0.022 mm in line width. Measured differences between patient and phantom were less than 12 HU for soft tissue and 15 HU for bone marrow, and 514 HU for cortical bone. The calcium-doped filament accurately represented bony tissue structures across different X-ray energies in spectral CT (RMSE ranging from ± 3 to ± 28 HU, compared to 400 mg/ml hydroxyapatite). In conclusion, this study demonstrated the possibility of extending 3D-printed patient-based phantoms to soft tissue and bone structures while maintaining accurate organ geometry, image texture, and attenuation profiles.

18 March 2015
Verified
Conference Paper
Open access
PDF file
RNRadin A. Nasirudin
Radin A. Nasirudin
RTRie Tachibana
Rie Tachibana
JNJanne J. Näppi
Janne J. Näppi
KMKai Mei
Kai Mei
FKFelix K. Kopp
Felix K. Kopp
PNPeter B. Noël
Peter B. Noël
In recent years, dual-energy computed tomography (DECT) has been widely used in the clinical routine due to improved diagnostics capability from additional spectral information. One promising application for DECT is CT colonography (CTC) in combination with computer-aided diagnosis (CAD) for detection of lesions and polyps. While CAD has demonstrated in the past that it is able to detect small polyps, its performance is highly dependent on the quality of the input data. The presence of artifacts such as beam-hardening and noise in ultra-low-dose CTC may severely degrade detection performances of small polyps. In this work, we investigate and compare virtual monochromatic images, generated by image-based decomposition and projection-based decomposition, with respect to CAD performance. In the image-based method, reconstructed images are firstly decomposed into water and iodine before the virtual monochromatic images are calculated. On the contrary, in the projection-based method, the projection data are first decomposed before calculation of virtual monochromatic projection and reconstruction. Both material decomposition methods are evaluated with regards to the accuracy of iodine detection. Further, the performance of the virtual monochromatic images is qualitatively and quantitatively assessed. Preliminary results show that the projection-based method does not only have a more accurate detection of iodine, but also delivers virtual monochromatic images with reduced beam hardening artifacts in comparison with the image-based method. With regards to the CAD performance, the projection-based method yields an improved detection performance of polyps in comparison with that of the image-based method.

24 August 2018 in Osteoporosis International
Verified
Journal Article
Open access
Nico SollmannNico Sollmann
Nico Sollmann
KMK. Mei
K. Mei
BSB.J. Schwaiger
B.J. Schwaiger
AGAlexandra S. Gersing
Alexandra S. Gersing
FKF.K. Kopp
F.K. Kopp
TBThomas Baum
Thomas Baum
Summary This study investigates the impact of tube current reduction and sparse sampling on femoral bone mineral density (BMD) measurements derived from multi-detector computed tomography (MDCT). The application of sparse sampling led to robust and clinically acceptable BMD measurements. In contrast, BMD measurements derived from MDCT with virtually reduced tube currents showed a considerable increase when compared to original data. Introduction The study aims to evaluate the effects of radiation dose reduction by using virtual reduction of tube current or sparse sampling combined with standard filtered back projection (FBP) and statistical iterative reconstruction (SIR) on femoral bone mineral density (BMD) measurements derived from multi-detector computed tomography (MDCT). Methods In routine MDCT scans of 41 subjects (65.9% men; age 69.3 ± 10.1 years), reduced radiation doses were simulated by lowering tube currents and applying sparse sampling (50, 25, and 10% of the original tube current and projections, respectively). Images were reconstructed using FBP and SIR. BMD values were assessed in the femoral neck and compared between the different dose levels, numbers of projections, and image reconstruction approaches. Results Compared to full-dose MDCT, virtual lowering of the tube current by applying our simulation algorithm resulted in increases in BMD values for both FBP (up to a relative change of 32.5%) and SIR (up to a relative change of 32.3%). In contrast, the application of sparse sampling with a reduction down to 10% of projections showed robust BMD values, with clinically acceptable relative changes of up to 0.5% (FBP) and 0.7% (SIR). Conclusions Our simulations, which still require clinical validation, indicate that reductions down to ultra-low tube currents have a significant impact on MDCT-based femoral BMD measurements. In contrast, the application of sparse-sampled MDCT seems a promising future clinical option that may enable a significant reduction of the radiation dose without considerable changes of BMD values.