Fluorescence from four emission points is collimated by four lenses, split into four-color fluxes by four dichroic mirrors, and directly input into the image sensor.
An ultra-small and highly efficient spectral-detection system for four emission points was developed by integrating an injection-molded-plastic four-lens array, a seven-dichroic-mirror array, and an image sensor as one device. The seven-dichroic-mirror array was further miniaturized compared to our previous four-dichroic-mirror array by measures including reduction of the thickness of each dichroic mirror from 1.0 to 0.5 mm. As a result, the system enables highly sensitive and low-crosstalk seven-color detection of laser-induced fluorescence from four emission points of a four-capillary array. This capability allows simultaneous quantification of up-to-seven fluorophores concurrently present in each capillary. Sanger DNA sequencing and STR genotyping by four-capillary-array electrophoresis were experimentally demonstrated by the system.
Mutant (MT) in a large excess of wild type (WT) was quantified with high-sensitivity (LOD of 0.004% MT/WT) and four-orders-of-magnitude dynamic range (0.01–100% MT/WT) by a high-dynamic-range capillary-array electrophoresis (HiDy CE).
Fluorescence from eight A channels and Raman-scattered light from seven B channels, induced by a side-entry laser beam, were simultaneously, uniformly, and spectroscopically detected.
1 February 2011 in Review of Scientific Instruments
We developed a total-internal-reflection (TIR) fluorescence microscopy using three dichroic mirrors and four charge-coupled devices (CCDs) to detect simultaneously four colors of single-molecule (SM) fluorophores. Four spectrally distinct species of fluorophores (Alexa 488, Cy3, Cy5, or Cy5.5) were each immobilized on a different fused silica slide. A species of fluorophores on the slide was irradiated simultaneously, by two excitation beams from an Ar ion laser (488 and 514.5 nm) and a diode laser (642 nm) through TIR on the slide surface. Fluorescence emitted from the fluorophores was spectrally resolved into four components by the dichroic mirrors, and four images were generated from them simultaneously and continuously, with the four CCDs at a rate of 10 Hz. A series of images was thus obtained with each CCD. Fluorescence spots for a species were observed mainly in the series of images recorded by its respective-color CCD. In the first image in the series, we picked out the spots as continuous pixel regions that had the values greater than a threshold. Then we selected only those spots that exhibited single-step photobleaching and regarded them as SM fluorescence spots. Pixel values of SM fluorescence spots widely differed. Some SM fluorophores had pixel values smaller than the threshold, and were left unpicked. Assuming the pixel values of SM fluorescence spots differed with a Gaussian profile, we estimated the ratios of unpicked fluorophores to be less than 20% for all the species. Because of the spectral overlaps between species, we also observed cross-talk spots into CCDs other than the respective-color CCDs. These cross-talk SM fluorescence spots can be mistaken for correct species. We thus introduced the classification method and classified SM fluorescence spots into correct species in accordance with two kinds of four-dimensional signal vectors. The error rates of fluorophore classification were estimated to be less than 3.2% for all the species. Our system is suitable for the biological studies that desire to simultaneously monitor the four colors of SM fluorophores.