Tomoyuki Sakai

Tomoyuki Sakai

Auto-generated profile, based on publicly available information

Tomoyuki Sakai

Department of Hematology and Immunology, Kanazawa Medical University, 1-1 Daigaku, Uchinada-machi, Kahoku-gun, Ishikawa-ken 920-0293, Japan

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2021 in Clinica Chimica Acta
Verified
Journal Article
Open access
TKTakafumi Kawanami
Takafumi Kawanami
HKHaruka Kawanami-Iwao
Haruka Kawanami-Iwao
TTTakanobu Takata
Takanobu Takata
Yasuhito IshigakiYasuhito Ishigaki
Yasuhito Ishigaki
NTNaohisa Tomosugi
Naohisa Tomosugi
YMYasufumi Masaki
Yasufumi Masaki
Background and aims Immunoglobulin 4 (IgG4)-related disease (IgG4-RD) is a lymphoproliferative disorder characterized by elevated serum IgG4 levels and tissue infiltration of IgG4-positive plasma cells. We analyzed the serum proteins, whose levels varied based on the disease state and treatment. Materials and methods Serum proteins from patients with IgG4-related disease and healthy subjects were resolved using two-dimensional electrophoresis, silver-stained, and scanned. Alternatively, the proteins were labeled with Cy2, Cy3, and Cy5 before electrophoresis. The proteins, whose expression differed significantly between patients and healthy individuals, and between before and after steroid treatment, were identified and validated using enzyme-linked immunosorbent assays. Results: Pre-treatment sera from patients with IgG4-related disease was characterized by increased levels of immunoglobulins such as IgG1, IgG4; inflammatory factors such as α-1 antitrypsin (A1AT); and proteins associated with immune system regulation such as clusterin and leucine-rich α-2-glycoprotein (LRG-1). The serum levels of A1AT, LRG-1 and clusterin, during treatment with prednisolone for up to 12 months revealed that LRG-1 levels were halved after 1 month of treatment, comparable to those in healthy subjects; LRG-1 levels remained normal until the end of treatment. Conclusion: LRG-1 could serve as a novel biomarker of IgG4-related diseases.

1 February 2011 in Review of Scientific Instruments
Verified
Journal Article
Closed access
THTakanobu Haga
Takanobu Haga
TSTsuyoshi Sonehara
Tsuyoshi Sonehara
TSTomoyuki Sakai
Tomoyuki Sakai
TATakashi Anazawa
Takashi Anazawa
Takeshi FujitaTakeshi Fujita
Takeshi Fujita
STSatoshi Takahashi
Satoshi Takahashi
We developed a total-internal-reflection (TIR) fluorescence microscopy using three dichroic mirrors and four charge-coupled devices (CCDs) to detect simultaneously four colors of single-molecule (SM) fluorophores. Four spectrally distinct species of fluorophores (Alexa 488, Cy3, Cy5, or Cy5.5) were each immobilized on a different fused silica slide. A species of fluorophores on the slide was irradiated simultaneously, by two excitation beams from an Ar ion laser (488 and 514.5 nm) and a diode laser (642 nm) through TIR on the slide surface. Fluorescence emitted from the fluorophores was spectrally resolved into four components by the dichroic mirrors, and four images were generated from them simultaneously and continuously, with the four CCDs at a rate of 10 Hz. A series of images was thus obtained with each CCD. Fluorescence spots for a species were observed mainly in the series of images recorded by its respective-color CCD. In the first image in the series, we picked out the spots as continuous pixel regions that had the values greater than a threshold. Then we selected only those spots that exhibited single-step photobleaching and regarded them as SM fluorescence spots. Pixel values of SM fluorescence spots widely differed. Some SM fluorophores had pixel values smaller than the threshold, and were left unpicked. Assuming the pixel values of SM fluorescence spots differed with a Gaussian profile, we estimated the ratios of unpicked fluorophores to be less than 20% for all the species. Because of the spectral overlaps between species, we also observed cross-talk spots into CCDs other than the respective-color CCDs. These cross-talk SM fluorescence spots can be mistaken for correct species. We thus introduced the classification method and classified SM fluorescence spots into correct species in accordance with two kinds of four-dimensional signal vectors. The error rates of fluorophore classification were estimated to be less than 3.2% for all the species. Our system is suitable for the biological studies that desire to simultaneously monitor the four colors of SM fluorophores.