Gregory Delpon

Gregory Delpon

Auto-generated profile, based on publicly available information

Gregory Delpon

Nantes Université IMT Atlantique, CNRS/IN2P3, SUBATECH France

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2016 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
GDGrégory Delpon
Grégory Delpon
AEAlexandre Escande
Alexandre Escande
TRTimothée Ruef
Timothée Ruef
JDJulien Darréon
Julien Darréon
JFJimmy Fontaine
Jimmy Fontaine
DPDavid Pasquier
David Pasquier
Automated atlas-based segmentation algorithms present the potential to reduce the variability in volume delineation. Several vendors offer software that are mainly used for cranial, head and neck and prostate cases. The present study will compare the contours produced by a radiation oncologist to the contours computed by different automated atlas-based segmentation algorithms for prostate bed cases, including femoral heads, bladder and rectum. Contour comparison was evaluated by different metrics such as volume ratio, Dice coefficient and Hausdorff distance. Results depended on the volume of interest and showed some discrepancies between the different software. Automatic contours could be a good starting point for the delineation of organs since efficient editing tools are provided by different vendors. It should become an important help in the next few years for organ at risk delineation.

1 December 2010 in Cancer Research
Verified
Journal Article
Open access
PDF file
SBStéphanie Bonnaud
Stéphanie Bonnaud
CNColin Niaudet
Colin Niaudet
FLFrançois Legoux
François Legoux
ICIsabelle Corre
Isabelle Corre
GDGregory Delpon
Gregory Delpon
FPFrançois Paris
François Paris
A previous in vitro study showed that sphingosine-1-phosphate (S1P), a ceramide antagonist, preserved endothelial cells in culture from radiation-induced apoptosis. We proposed to validate the role of S1P in tissue radioprotection by inhibiting acute gastrointestinal (GI) syndrome induced by endothelial cell apoptosis after high dose of radiation. Retro-orbital S1P was injected in mice exposed to 15 Gy, a dose-inducing GI syndrome within 10 days. Overall survival and apoptosis on intestines sections were studied. Intestinal cell type targeted by S1P and early molecular survival pathways were researched using irradiated in vitro cell models and in vivo mouse models. We showed that retro-orbital S1P injection before irradiation prevented GI syndrome by inhibiting endothelium collapse. We defined endothelium as a specific therapeutic target because only these cells and not intestinal epithelial cells, or B and T lymphocytes, were protected. Pharmacologic approaches using AKT inhibitor and pertussis toxin established that S1P affords endothelial cell protection in vitro and in vivo through a mechanism involving AKT and 7-pass transmembrane receptors coupled to Gi proteins. Our results provide strong pharmacologic and mechanistic proofs that S1P protects endothelial cells against acute radiation enteropathy. Cancer Res; 70(23); 9905–15. ©2010 AACR.

2 January 2020 in Cancers
Verified
Journal Article
Open access
PDF file
KCKaren Clément-Colmou
Karen Clément-Colmou
VPVincent Potiron
Vincent Potiron
MPManon Pietri
Manon Pietri
MGMaëva Guillonneau
Maëva Guillonneau
EJEmmanuel Jouglar
Emmanuel Jouglar
Stéphane SupiotStéphane Supiot
Stéphane Supiot
Background. The tumor vasculature acts as an interface for the primary tumor. It regulates oxygenation, nutrient delivery, and treatment efficacy including radiotherapy. The response of the tumor vasculature to different radiation doses has been disparately reported. Whereas high single doses can induce endothelial cell death, improved vascular functionality has also been described in a various dose range, and few attempts have been made to reconcile these findings. Therefore, we aimed at comparing the effects of different radiation fractionation regimens on the tumor vascular microenvironment. Methods: Lewis lung and prostate PC3 carcinoma-derived tumors were irradiated with regimens of 10 × 2 Gy, 6 × 4 Gy, 3 × 8 Gy or 2 × 12 Gy fractions. The tumor vasculature phenotype and function was evaluated by immunohistochemistry for endothelial cells (CD31), pericytes (desmin, α-SMA), hypoxia (pimonidazole) and perfusion (Hoechst 33342). Results: Radiotherapy increased vascular coverage similarly in all fractionation regimens in both models. Vessel density appeared unaffected. In PC3 tumors, hypoxia was decreased and perfusion was enhanced in proportion with the dose per fraction. In LLC tumors, no functional changes were observed at t = 15 days, but increased perfusion was noticed earlier (t = 9–11 days). Conclusion: The vascular microenvironment response of prostate and lung cancers to radiotherapy consists of both tumor/dose-independent vascular maturation and tumor-dependent functional parameters.

24 November 2014 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
FSF Smekens
F Smekens
Jean Michel LétangJean Michel Létang
Jean Michel Létang
CNC Noblet
C Noblet
SCS Chiavassa
S Chiavassa
GDG Delpon
G Delpon
DSDavid Sarrut
David Sarrut
We propose the split exponential track length estimator (seTLE), a new kerma-based method combining the exponential variant of the TLE and a splitting strategy to speed up Monte Carlo (MC) dose computation for low energy photon beams. The splitting strategy is applied to both the primary and the secondary emitted photons, triggered by either the MC events generator for primaries or the photon interactions generator for secondaries. Split photons are replaced by virtual particles for fast dose calculation using the exponential TLE. Virtual particles are propagated by ray-tracing in voxelized volumes and by conventional MC navigation elsewhere. Hence, the contribution of volumes such as collimators, treatment couch and holding devices can be taken into account in the dose calculation.We evaluated and analysed the seTLE method for two realistic small animal radiotherapy treatment plans. The effect of the kerma approximation, i.e. the complete deactivation of electron transport, was investigated. The efficiency of seTLE against splitting multiplicities was also studied. A benchmark with analog MC and TLE was carried out in terms of dose convergence and efficiency.The results showed that the deactivation of electrons impacts the dose at the water/bone interface in high dose regions. The maximum and mean dose differences normalized to the dose at the isocenter were, respectively of 14% and 2% . Optimal splitting multiplicities were found to be around 300. In all situations, discrepancies in integral dose were below 0.5% and 99.8% of the voxels fulfilled a 1%/0.3 mm gamma index criterion. Efficiency gains of seTLE varied from 3.2 × 10(5) to 7.7 × 10(5) compared to analog MC and from 13 to 15 compared to conventional TLE.In conclusion, seTLE provides results similar to the TLE while increasing the efficiency by a factor between 13 and 15, which makes it particularly well-suited to typical small animal radiation therapy applications.

1 February 2014 in Physica Medica
Verified
Journal Article
Closed access
CNC. Noblet
C. Noblet
SCS. Chiavassa
S. Chiavassa
FPF. Paris
F. Paris
Stéphane SupiotStéphane Supiot
Stéphane Supiot
ALA. Lisbona
A. Lisbona
GDG. Delpon
G. Delpon

1 October 2010 in Cancer/Radiothérapie
Verified
Journal Article
Closed access
ALA. Lisbona
A. Lisbona
DAD. Averbeck
D. Averbeck
Stéphane SupiotStéphane Supiot
Stéphane Supiot
GDG. Delpon
G. Delpon
DAD. Ali
D. Ali
JLJ.-L. Lagrange
J.-L. Lagrange