A vacuum assisted UV micro-molding (VAUM) process is proposed for the fabrication of freestanding and defect-free polymer membranes based on a UV-curable methacrylate polymer (MD 700). VAUM is a highly flexible and powerful method for fabricating low cost, robust, large-area membranes over 9 × 9 cm2 with pore sizes from 8 to 20 μm in diameter, 20 to 100 μm in thickness, high aspect ratio (the thickness of the polymer over the diameter of the hole is up to 15 : 1), high porosity, and a wide variety of geometrical characteristics. The fabricated freestanding membranes are flexible while mechanically robust enough for post manipulation and handling, which allows them to be cut and integrated as a plastic cartridge onto thermoplastic 3D microfluidic devices with single or double filtration stages. Very high particle capture efficiencies (≈98%) have been demonstrated in the microfluidic devices integrated with polymer membranes, even when the size of the beads is very close to the size of the pores of the microfilter. About 85% of the capture efficiency has been achieved in cancer cell trapping experiments, in which a breast cancer cell line (MDA-MB-231) spiked with phosphate-buffered saline buffer when the pore size of the filter is 8 μm and the device is operated at a flow rate of 0.1 mL min−1.
A method modifying a vacuum-assisted UV micro-molding (VAUM) process is proposed for the fabrication of polymer two-level submicron high porosity membranes (2LHPM). The modified process allows for the fabrication of robust, large-area membranes over 5 × 5 cm2 with a hierarchical architecture made from a 200 nm-thick layer having submicron level pores (as small as 500 nm) supported by a 20 μm-thick layer forming a microporous structure with 10–15 μm diameter pores. The fabricated freestanding membranes are flexible and mechanically robust enough for post manipulation and filtration of cell samples. Very high white blood cell (WBC) capture efficiencies (≈97%) from healthy blood samples after red blood cell (RBC) lysis are demonstrated using a 3D-printed filter cartridge incorporated within these 2LHPM. A high release efficiency of ≈95% is also proved using the same setup. Finally, on-filter multistep immunostaining of captured cells is also shown.
A stretchable capacitive strain sensor based on thermoplastic elastomer (TPE) microfluidics embedded with liquid metal was successfully fabricated. Benefiting from the unique self-bonding feature of the TPE materials, the capacitance of a sensor was enhanced by increasing the number of TPE layers without changing the footprint of the sensor. The change of the sensor capacitance is linearly dependent on the strain with small hysteresis. The gauge factor of the sensor is closed to the theoretical maximum value 1. The capacitance of the sensor is very stable and repeatable after stretching and releasing for 5000 cycles.