21 August 2003 in American Journal of Medical Genetics Part A
MCMalwina Czarny‐Ratajczak
+6
18 January 2011 in Rapid Prototyping Journal
Purpose – The aim of this paper is to present the main results of a research project finished in 2008 which concerned the selective laser melted (SLM) prototype of a new kind of minimally invasive resurfacing hip arthroplasty (RHA) endoprosthesis with the original multi-spiked connecting scaffold (MSC-Scaffold). Previous attempts performed in pre-Direct Metal Manufacturing (DMM) era demonstrated that it was impossible to manufacture suitable prototypes of this RHA endoprosthesis (especially of the MSC-Scaffold) using traditional machining technologies. Owing to an extensive development of DMM technologies observed in recent years the manufacturing of such prototypes has become possible. Design/methodology/approach – Computer aided design models of pre-prototypes and the prototype of the RHA endoprosthesis with MSC-Scaffold were designed and initially optimized within the claims and the general assumptions of international patents by Rogala. Prototyping in SLM technology was subcontracted to SLM Tech Center (Paderborn, Germany). Macroscopic and SEM microscopic evaluation of the MSC-Scaffold was performed using SLM manufactured prototypes and paying special attention to the quality and precision of manufacturing. Findings – It was found that SLM can be successfully applied to manufacturing of prototypes of the original minimally invasive RHA endoprosthesis. The manufacturing quality of the 3D spikes system of the MSC-Scaffold, which mimics the interdigitations of articular subchondral bone, has been proved to be geometrically corresponding to the biological original. Nevertheless, some pores and non-melted zones were found in SLM prototyped RHA endoprosthesis cross-sections which need to be eliminated to minimize the potential risk of clinical failure. Research limitations/implications – The presented case study was performed with a limited number of samples. More research needs to be performed on the rapid prototyped samples including microstructural and mechanical tests. The results may enable the optimization of the SLM manufacturing process of the prototypes of the minimally invasive RHA endoprosthesis with MSC-Scaffold. Practical implications – The SLM can be considered as potentially suitable for the fabrication of patient-fitted minimally invasive RHA endoprostheses with MSC-Scaffold. Originality/value – For the first time, largely owing to SLM technology, it was possible to manufacture the prototype of the original minimally invasive RHA endoprosthesis with MSC-Scaffold suitable for further research.
12 November 2010 in American Journal of Medical Genetics Part A
4 July 2018 in Computer Methods in Biomechanics and Biomedical Engineering
The multispiked connecting scaffold (MSC-scaffold) prototype is an essential innovation in the fixation of components of resurfacing arthroplasty (RA) endoprostheses, providing their entirely non-cemented and bone-tissue-preserving fixation in peri-articular bone. An FE study is proposed to evaluate the influence of geometrical features of the MSC-scaffold on the transfer of mechanical load in peri-implant bone. For this study, an FE model of Ti-Alloy MSC-scaffold prototype embedded in a bilinear elastic, transversely isotropic bone material was built. For the compressive load on the MSC-scaffold, maps of Huber-Mises-Hencky (HMH) stress in peri-implant bone were determined. The influence of the distance between the bases of neighbouring spikes, the apex angle of spikes, and the height of the spherical cup of spikes of the MSC-scaffold were analysed. It was found that the changes in the distance between the bases of neighbouring spikes from 0.2 to 0.5 mm cause the HMH stress to increase in bone material by 32%. The changes of the apex angle of spikes from 2° to 4° decrease the HMH stress in bone material by 39%. The changes of height of the spherical cup of spikes from 0 to 0.12 mm increase the HMH stress in bone material by 24%. In conclusion, the spikes’ apex angle and the distance between the bases of spikes of the MSC-scaffold are the key geometrical features determining the appropriate MSC-scaffold prototype design. The built FE model was found to be useful in bioengineering design of the novel fixation system for RA endoprostheses by means of the MSC-scaffold.
1 August 2009 in International Journal of Rehabilitation Research