Ryszard Uklejewski

Prof. Ryszard Uklejewski

Chair of Constructional Materials and Biomaterials, Institute of Material Engineering, Kazimierz Wielki University, Bydgoszcz, Poland
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
AZAnetta Zioła-Frankowska
Anetta Zioła-Frankowska
ŁKŁukasz Kubaszewski
Łukasz Kubaszewski
Mikolaj DabrowskiMikolaj Dabrowski
Mikolaj Dabrowski
AKArtur Kowalski
Artur Kowalski
PRPiotr Rogala
Piotr Rogala
Marcin FrankowskiMarcin Frankowski
Marcin Frankowski
The aim of the study was to determine the content of particular elements Ca, Mg, P, Na, K, Zn, Cu, Fe, Mo, Cr, Ni, Ba, Sr, and Pb in the proximal femur bone tissue (cancellous and cortical bone) of 96 patients undergoing total hip replacement for osteoarthritis using ICP-AES and FAAS analytical techniques. The interdependencies among these elements and their correlations depended on factors including age, gender, place of residence, tobacco consumption, alcohol consumption, exposure to environmental pollution, physical activity, and type of degenerative change which were examined by statistical and chemometric methods. The factors that exerted the greatest influence on the elements in the femoral head and neck were tobacco smoking (higher Cr and Ni content in smokers), alcohol consumption (higher concentrations of Ni, Cu in people who consume alcohol), and gender (higher Cu, Zn, and Ni concentrations in men). The factors influencing Pb accumulation in bone tissue were tobacco, alcohol, gender, and age. In primary and secondary osteoarthritis of the hip, the content and interactions of elements are different (mainly those of Fe and Pb). There were no significant differences in the concentrations of elements in the femoral head and neck that could be attributed to residence or physical activity.

18 January 2011 in Rapid Prototyping Journal
Verified
Journal Article
Closed access
PDF file
Ryszard UklejewskiRyszard Uklejewski
Ryszard Uklejewski
Mariusz WinieckiMariusz Winiecki
Mariusz Winiecki
PRPiotr Rogala
Piotr Rogala
JMJanusz Mielniczuk
Janusz Mielniczuk
Purpose – The aim of this paper is to present the main results of a research project finished in 2008 which concerned the selective laser melted (SLM) prototype of a new kind of minimally invasive resurfacing hip arthroplasty (RHA) endoprosthesis with the original multi-spiked connecting scaffold (MSC-Scaffold). Previous attempts performed in pre-Direct Metal Manufacturing (DMM) era demonstrated that it was impossible to manufacture suitable prototypes of this RHA endoprosthesis (especially of the MSC-Scaffold) using traditional machining technologies. Owing to an extensive development of DMM technologies observed in recent years the manufacturing of such prototypes has become possible. Design/methodology/approach – Computer aided design models of pre-prototypes and the prototype of the RHA endoprosthesis with MSC-Scaffold were designed and initially optimized within the claims and the general assumptions of international patents by Rogala. Prototyping in SLM technology was subcontracted to SLM Tech Center (Paderborn, Germany). Macroscopic and SEM microscopic evaluation of the MSC-Scaffold was performed using SLM manufactured prototypes and paying special attention to the quality and precision of manufacturing. Findings – It was found that SLM can be successfully applied to manufacturing of prototypes of the original minimally invasive RHA endoprosthesis. The manufacturing quality of the 3D spikes system of the MSC-Scaffold, which mimics the interdigitations of articular subchondral bone, has been proved to be geometrically corresponding to the biological original. Nevertheless, some pores and non-melted zones were found in SLM prototyped RHA endoprosthesis cross-sections which need to be eliminated to minimize the potential risk of clinical failure. Research limitations/implications – The presented case study was performed with a limited number of samples. More research needs to be performed on the rapid prototyped samples including microstructural and mechanical tests. The results may enable the optimization of the SLM manufacturing process of the prototypes of the minimally invasive RHA endoprosthesis with MSC-Scaffold. Practical implications – The SLM can be considered as potentially suitable for the fabrication of patient-fitted minimally invasive RHA endoprostheses with MSC-Scaffold. Originality/value – For the first time, largely owing to SLM technology, it was possible to manufacture the prototype of the original minimally invasive RHA endoprosthesis with MSC-Scaffold suitable for further research.

29 July 2013 in BioMed Research International
Verified
Journal Article
Open access
PDF file
Ryszard UklejewskiRyszard Uklejewski
Ryszard Uklejewski
PRPiotr Rogala
Piotr Rogala
Mariusz WinieckiMariusz Winiecki
Mariusz Winiecki
AKAndrzej Kędzia
Andrzej Kędzia
Piotr RuszkowskiPiotr Ruszkowski
Piotr Ruszkowski
We present the new fixation method for RHA (resurfacing hip arthroplasty) endoprostheses by means of the biomimetic multispiked connecting scaffold (MSC-Scaffold). Such connecting scaffold can generate new type of RHA endoprostheses, that is stemless and fixed entirely without cement. The preprototypes of this MSC-Scaffold were manufactured with modern additive laser additive technology (SLM). The pilot surgical implantations in animal model (two laboratory swine) of MSC-Scaffold preprototypes have showed after two months neither implant loosening, migration, and nor other early complications. From the results of performed histopathological evaluation of the periscaffold spikes bone tissue and 10-day culture of human osteoblasts (NHOst) we can conclude that (1) the scaffolding effect was obtained and (2) to improve the osseointegration of the scaffold spikes, their material surface should be physicochemically modified (e.g., with hydroxyapatite). Some histopathological findings in the periscaffold domain near the MSC-Scaffold spikes bases (fibrous connective tissue and metallic particles near the MSC-Scaffold spikes bases edges) prompt considering the necessity to optimize the design of the MSC-Scaffold in the regions of its interspike space near the spikes bases edges, to provide more room for new bone formation in this region and for indispensable post-processing (glass pearl blasting) after the SLM manufacturing.

29 June 2016 in Materials
Verified
Journal Article
Open access
PDF file
Ryszard UklejewskiRyszard Uklejewski
Ryszard Uklejewski
PRPiotr Rogala
Piotr Rogala
Mariusz WinieckiMariusz Winiecki
Mariusz Winiecki
RTRenata Tokłowicz
Renata Tokłowicz
Piotr RuszkowskiPiotr Ruszkowski
Piotr Ruszkowski
MWMaria Wolun-Cholewa
Maria Wolun-Cholewa
We present here—designed, manufactured, and tested by our research team—the Ti-alloy prototype of the multispiked connecting scaffold (MSC-Scaffold) interfacing the components of resurfacing arthroplasty (RA) endoprostheses with bone. The spikes of the MSC-Scaffold prototype mimic the interdigitations of the articular subchondral bone, which is the natural biostructure interfacing the articular cartilage with the periarticular trabecular bone. To enhance the osteoinduction/osteointegration potential of the MSC-Scaffold, the attempts to modify its bone contacting surfaces by the process of electrochemical cathodic deposition of Ca-P was performed with further immersion of the MSC-Scaffold prototypes in SBF in order to transform the amorphous calcium-phosphate coating in hydroxyapatite-like (HA-like) coating. The pilot experimental study of biointegration of unmodified and Ca-P surface-modified MSC-Scaffold prototypes was conducted in an animal model (swine) and in osteoblast cell culture. On the basis of a microscope-histological method the biointegration was proven by the presence of trabeculae in the interspike spaces of the MSC-Scaffold prototype on longitudinal and cross-sections of bone-implant specimens. The percentage of trabeculae in the area between the spikes of specimen containing Ca-P surface modified scaffold prototype observed in microCT reconstructions of the explanted joints was visibly higher than in the case of unmodified MSC-Scaffold prototypes. Significantly higher Alkaline Phosphatase (ALP) activity and the cellular proliferation in the case of Ca-P-modified MSC-Scaffold pre-prototypes, in comparison with unmodified pre-prototypes, was found in osteoblast cell cultures. The obtained results of experimental implantation in an animal model and osteoblast cell culture evaluations of Ca-P surface-modified and non-modified biomimetic MSC-Scaffold prototypes for biomimetic entirely-cementless RA endoprostheses indicate the enhancement of the osteoinduction/osteointegration potential by the Ca-P surface modification of the Ti-alloy MSC-Scaffold prototype. Planned further research on the prototype of this biomimetic MSC-Scaffold for a new generation of RA endoprostheses is also given.

1 April 2015 in Biotechnology and Bioprocess Engineering
Verified
Journal Article
Closed access
PDF file
Ryszard UklejewskiRyszard Uklejewski
Ryszard Uklejewski
Mariusz WinieckiMariusz Winiecki
Mariusz Winiecki
GMGrzegorz Musielak
Grzegorz Musielak
RTRenata Tokłowicz
Renata Tokłowicz

12 March 2021 in Materials
Verified
Journal Article
Open access
PDF file
Ryszard UklejewskiRyszard Uklejewski
Ryszard Uklejewski
Mariusz WinieckiMariusz Winiecki
Mariusz Winiecki
Adam PatalasAdam Patalas
Adam Patalas
PRPiotr Rogala
Piotr Rogala
Our team has been working for some time on designing a new kind of biomimetic fixation of resurfacing endoprostheses, in which the innovative multi-spiked connecting scaffold (MSC-Scaffold) that mimics the natural interface between articular cartilage and periarticular trabecular bone in human joints is the crucial element. This work aimed to develop a numerical model enabling the design of the considered joint replacement implant that would reflect the mechanics of interacting biomaterials. Thus, quantitative micro-CT analysis of density distribution in bone material during the embedding of MSC-Scaffold in periarticular bone was applied. The performed numerical studies and corresponding mechanical tests revealed, under the embedded MSC-Scaffold, the bone material densification affecting its mechanical properties. On the basis of these findings, the built numerical model was modified by applying a simulated insert of densified bone material. This modification led to a strong correlation between the re-simulation and experimental results (FVU = 0.02). The biomimetism of the MSC-Scaffold prototype that provided physiological load transfer from implant to bone was confirmed based on the Huber–von Mises–Hencky (HMH) stress maps obtained with the validated finite element (FE) model of the problem. The micro-CT bone density assessment performed during the embedding of the MSC-Scaffold prototype in periarticular bone provides insight into the mechanical behaviour of the investigated implant-bone system and validates the numerical model that can be used for the design of material and geometric features of a new kind of resurfacing endoprostheses fixation.