With the incidence rate exceeding 11% in the United States and 15%1 in the developing countries, preterm birth (PTB), defined as labor prior to 37 weeks of gestation, is the leading cause of infant death worldwide. PTB is reported to be responsible for infant neurological disorders,2 long-term cognitive impairment,3 as well as chronic health issues involving the auditory, visual, digestive, and respiratory systems.4 In expectant mothers, causes for PTB can include infection, inflammation,5 vascular disease,6 short intervals between pregnancies,7 multiple gestations,6 and genetic factors.8
The use of polarized light in clinical and preclinical applications is expanding,1 and several recent reviews by Tuchin,2 Ghosh and Vitkin,3 Qi and Elson,4 de Boer et al.,5 and Baumann6 have illustrated the fast progress of this approach in the medical field.
We propose an approach for discriminating fibrillar collagen fibers from elastic fibers in the mouse cervix in Mueller matrix microscopy using convolutional neural networks (CNN) and K-nearest neighbor (K-NN) for classification. Second harmonic generation (SHG), two-photon excitation fluorescence (TPEF), and Mueller matrix polarimetry images of the mice cervix were collected with a self-validating Mueller matrix micro-mesoscope (SAMMM) system. The components and decompositions of each Mueller matrix were arranged as individual channels of information, forming one 3-D voxel per cervical slice. The classification algorithms analyzed each voxel and determined the amount of collagen and elastin, pixel by pixel, on each slice. SHG and TPEF were used as ground truths. To assess the accuracy of the results, mean-square error (MSE), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM) were used. Although the training and testing is limited to 11 and 5 cervical slices, respectively, MSE accuracy was above 85%, SNR was greater than 40 dB, and SSIM was larger than 90%.
Reflectance Mueller matrix (MM) polarimetry is being used to characterize biological media in multiple clinical applications. The origin of the reflectance polarimetric data is often unclear due to the impact of multiple scattering and tissue heterogeneity. We have developed a new, to the best of our knowledge, multimodal imaging technique combining MM reflectance, MM digital confocal imaging, and co-registered nonlinear microscopy techniques. The instrument unveils the origin of reflectance polarimetric signature in terms of confocal reflectance data. The reconstructed reflected MM demonstrates the capability of our method to provide depth-resolved 3D polarization response from complex biological media in terms of depolarization, retardance, and orientation parameters.
Advancing the practical utility of nonlinear optical microscopy requires continued improvement in imaging depth and contrast. We evaluated second‐harmonic generation (SHG) and third‐harmonic generation images from ex vivo human skin and showed that a sub‐40 fs, 1060‐nm Yb‐fiber laser can enhance SHG penetration depth by up to 80% compared to a , 800 nm Ti:sapphire source. These results demonstrate the potential of fiber‐based laser systems to address a key performance limitation related to nonlinear optical microscopy (NLOM) technology while providing a low‐barrier‐to‐access alternative to Ti:sapphire sources that could help accelerate the movement of NLOM into clinical practice.
Mueller matrix polarimetry (MMP) is a promising linear imaging modality that can enable visualization and measurement of the polarization properties of the cornea. Although the distribution of corneal birefringence has been reported, depth resolved MMP imaging of the cornea has not been archived and remains challenging. In this work, we perform depth-resolved imaging of the cornea using an improved system that combines Mueller matrix reflectance and transmission microscopy together with nonlinear microscopy utilizing second harmonic generation (SHG) and two photon excitation fluorescence (TPEF). We show that TPEF can reveal corneal epithelial cellular network while SHG can highlight the presence of corneal stromal lamellae. We then demonstrate that, in confocal reflectance measurement, as depth increases from 0 to 80 μm both corneal depolarization and retardation increase. Furthermore, it is shown that the spatial distribution of corneal depolarization and retardation displays similar complexity in both reflectance (confocal and non-confocal) and transmission measurement, likely due to the strong degree of heterogeneity in the stromal lamellae.