M.E. Simon

M.E. Simon

Auto-generated profile, based on publicly available information

M.E. Simon

Philips Research Hamburg (M. Simon, A.T.), Hamburg, Germany

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2009 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
CJC.D.W. Jones
C.D.W. Jones
CBC.A. Bolle
C.A. Bolle
RRR. Ryf
R. Ryf
MSM.E. Simon
M.E. Simon
FPF. Pardo
F. Pardo
ARA.P. Ramirez
A.P. Ramirez

1 January 2002
Verified
Conference Paper
Closed access
VAVladimir Aksyuk
Vladimir Aksyuk
SAS. Arney
S. Arney
NBN.R. Basavanhally
N.R. Basavanhally
DBDavid Bishop
David Bishop
CBC.A. Bolle
C.A. Bolle
MSM.E. Simon
M.E. Simon
A fully provisioned 238/spl times/238 beam-steering optical crossconnect constructed using surface micromachined mirrors is described. The mean fiber-to-fiber insertion loss of the fabric is 1.33dB and the maximum insertion loss is 2dB.

13 April 2023 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
FSF. Ståhl
F. Ståhl
HAH. Almqvist
H. Almqvist
JKJ. Kolloch
J. Kolloch
ÅAÅ. Aspelin
Å. Aspelin
VGV. Gontu
V. Gontu
ADA.F. Delgado
A.F. Delgado
BACKGROUND AND PURPOSE: In patients with stroke, IV cone-beam CTA in the angiography suite could be an alternative to CTA to shorten the door-to-thrombectomy time. However, image quality in cone-beam CTA is typically limited by artifacts. This study evaluated a prototype dual-layer detector cone-beam CT angiography versus CTA in patients with stroke. MATERIALS AND METHODS: A prospective, single-center trial enrolled consecutive patients with ischemic or hemorrhagic stroke on initial CT. Intracranial arterial segment vessel conspicuity and artifact presence were evaluated on dual-layer cone-beam CTA 70-keV virtual monoenergetic images and CTA. Eleven predetermined vessel segments were matched for every patient. Twelve patients were necessary to show noninferiority to CTA. Noninferiority was determined by the exact binomial test; the 1-sided lower performance boundary was prospectively set to 80% (98.75% CI). RESULTS: Twenty-one patients had matched image sets (mean age, 72 years). After excluding examinations with movement or contrast media injection issues, all readers individually considered dual-layer cone-beam CT angiography noninferior to CTA (CI boundary, 93%, 84%, 80%, respectively) when evaluating arteries relevant in candidates for intracranial thrombectomy. Artifacts were more prevalent compared with CTA. The majority assessment rated each individual segment except M1 as having noninferior conspicuity compared with CTA. CONCLUSIONS: In a single-center stroke setting, dual-layer detector cone-beam CTA virtual monoenergetic images are noninferior to CTA under certain conditions. Notably, the prototype is hampered by a long scan time and is not capable of contrast media bolus tracking. After excluding examinations with such scan issues, readers considered dual-layer detector cone-beam CTA noninferior to CTA, despite more artifacts.