Qiuping Li

Qiuping Li

Auto-generated profile, based on publicly available information

Qiuping Li

The Key Laboratory of Integrated Microsystems, Peking University Shenzhen Graduate School, Shenzhen 518055, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Chen ZhangChen Zhang
Chen Zhang
JCJunfeng Chang
Junfeng Chang
YGYujiang Guan
Yujiang Guan
QLQiuping Li
Qiuping Li
XWXin’an Wang
Xin’an Wang
XZXing Zhang
Xing Zhang
The early detection of arrhythmia can effectively reduce the risk of serious heart diseases and save time for treatment. Many healthcare devices have been widely used for electrocardiogram (ECG) monitoring. However, most of them can only complete simple two-classes detection and have unacceptable hardware overhead and energy consumption. For achieving accurate and low-power arrhythmia detection, a novel ECG processor application specific integrated circuit (ASIC) is proposed in this paper, which can perform the prediction of five types of cardiac arrhythmias and heart rate monitoring. To realize hardware-efficient R-peak detection, an ECG pre-processing engine based on a first derivative and moving average comparison method is proposed. Efficient arrhythmia detection is realized by the proposed low-power classification engine, which is based on a carefully designed lightweight artificial neural network (ANN) with good prediction accuracy. The hardware reuse strategy is used to implement the hardware logic of ANN, where computations are executed by only one processing unit (PU), which is controlled by a flexible finite state machine (FSM). Also, the weights of ANN are configurable to facilitate model updates. We validate the functionality of the design using real-world ECG data. The proposed ECG processor is implemented using 55 nm CMOS technology, occupying an area of 0.33 mm2. This design consumes 12.88 μW at a 100 kHz clock frequency, achieving a classification accuracy of 96.69%. The comparison results with previous work indicate that our design has advantages in detection performance and power consumption, providing a good solution for low-power and low-cost ECG monitoring.

9 December 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Chen ZhangChen Zhang
Chen Zhang
XWXin’an Wang
Xin’an Wang
YSYong Shanshan
Yong Shanshan
YZYining Zhang
Yining Zhang
QLQiuping Li
Qiuping Li
WCwang chenyang
wang chenyang
Deep convolutional neural networks (CNNs) have shown strong abilities in the application of artificial intelligence. However, due to their extensive amount of computation, traditional processors have low energy efficiency when executing CNN algorithms, which is unacceptable for portable devices with limited hardware cost and battery capacity, so designing a CNN-specific processor is necessary. In this paper, we propose an energy-efficient CNN processor architecture for lightweight devices with a processing elements (PEs) array consisting of 384 PEs. Using the systolic array-based PE array, it realizes parallel operations between filter rows and between channels of output feature maps, supporting the acceleration of 3D convolution and fully connected computation with various parameters by configuring internal instruction registers. The computing strategy based on the proposed systolic dataflow achieves less hardware overhead compared with other strategies, and the reuse of image values and weight values, which effectively reduce the power of memory access. A memory system with a multi-level storage structure combined with register file (RF) and SRAM is used in the proposed CNN processor, which further reduces the energy overhead of computing. The proposed CNN processor architecture has been verified on a ZC706 FPGA platform using VGG-16 based on the proposed image segmentation method, the evaluation results indicate that the peak throughput achieves 115.2 GOP/s consuming 3.801 W at 150 MHz, energy efficiency and DSP efficiency reaches 30.32 GOP/s/W and 0.26 GOP/s/DSP, respectively.

1 January 2021 in Wireless Communications and Mobile Computing
Verified
Journal Article
Open access
PDF file
CQChangpei Qiu
Changpei Qiu
XWXin’an Wang
Xin’an Wang
TZTianxia Zhao
Tianxia Zhao
QLQiuping Li
Qiuping Li
BWBo Wang
Bo Wang
HWHu Wang
Hu Wang
In this paper, an FPGA‐based convolutional neural network coprocessor is proposed. The coprocessor has a 1D convolutional computation unit PE in row stationary (RS) streaming mode and a 3D convolutional computation unit PE chain in pulsating array structure. The coprocessor can flexibly control the number of PE array openings according to the number of output channels of the convolutional layer. In this paper, we design a storage system with multilevel cache, and the global cache uses multiple broadcasts to distribute data to local caches and propose an image segmentation method that is compatible with the hardware architecture. The proposed coprocessor implements the convolutional and pooling layers of the VGG16 neural network model, in which the activation value, weight value, and bias value are quantized using 16‐bit fixed‐point quantization, with a peak computational performance of 316.0 GOP/s and an average computational performance of 62.54 GOP/s at a clock frequency of 200 MHz and a power consumption of about 9.25 W.

3 March 2021 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
QLQiuping Li
Qiuping Li
TZTianxia Zhao
Tianxia Zhao
XWXin’an Wang
Xin’an Wang
CQChangpei Qiu
Changpei Qiu
BZBing Zhou
Bing Zhou
BWBo Wang
Bo Wang
In recent years, Traditional Chinese Medicine (TCM) has attracted more and more attention due to its good therapeutic effect, low cost, and convenience. This research is also a part of the goal of the modernization of TCM. Based on the meridian electric potential acquisition system independently developed by our project team, in this paper, we designed the human body's meridian electric potential acquisition scheme. We use principal component analysis (PCA) to prove that the meridional potential signal is derived from the ECG signal. Then, Inception ResNet V2 was used to classify acupoints and nonacupoints. Finally, the classification accuracy rate reached 86.59045265, and the F1 score = 0.72161642. This shows that acupoints and nonacupoints can be distinguished by their surface potential.

6 January 2021 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
CQChangpei Qiu
Changpei Qiu
TZTianxia Zhao
Tianxia Zhao
QLQiuping Li
Qiuping Li
XWXin’an Wang
Xin’an Wang
KXKanglin Xiao
Kanglin Xiao
BWBo Wang
Bo Wang
A low-power stable wideband current source for acupuncture point skin impedance measurements has been designed employing a differential architecture and negative feedback. The circuits extend bandwidth to 1MHz, reducing harmonic distortion to 0.24 at 1MHz. The output impedance is 37M at 100kHz and 11M at 1MHz. The stability of the output current of the current source when connected to different loads is below 0.1 at frequencies up to 500kHz and increases to 0.74 at 1MHz. The circuit was manufactured in a 0.13-μm CMOS technology and measured results are presented. The area of the current source is 0.09mm2 and its consumption is 1.2mW. It is intended for low-power acupuncture point skin impedance measurements.

25 April 2021 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
QLQiuping Li
Qiuping Li
XZXing Zhang
Xing Zhang
XWXin’an Wang
Xin’an Wang
TZTianxia Zhao
Tianxia Zhao
CQChangpei Qiu
Changpei Qiu
BZBing Zhou
Bing Zhou
As traditional Chinese medicine (TCM) has gained more and more recognition in the world, Chinese medicine has also played its important role. However, traditional Chinese medicine equipment is relatively deficient, with insufficient functions and low degree of digitalization. For example, existing auscultation equipment can obtain few human characteristic indicators, which is difficult to meet the needs of reference in traditional Chinese medicine diagnosis. Based on this, this paper designed a human body characteristic index detection system based on the principle of traditional Chinese medicine, which includes respiratory and heartbeat signal acquisition device, meridian and acupoint signal acquisition device, temperature signal acquisition device, pulse and blood pressure acquisition device, processing module, keyword module, and output module. The respiratory and heartbeat signal acquisition device is used to collect the respiratory and heartbeat signal of human body. Meridian acupoint signal acquisition device is used to collect human meridian acupoint radio signals. The temperature signal acquisition device is used to collect the infrared temperature light wave signal of human body. Pulse and blood pressure acquisition devices are used to collect pulse and blood pressure signals. The processing module is used to obtain one or more human body characteristic indicators according to one or more of the respiration and heartbeat signals, meridians and acupoints signals, temperature signals, pulse, and blood pressure, including Qi and blood characteristic indicators, viscera and six meridian characteristic indicators, and temperature characteristic indicators. The keyword corresponding module is used to obtain the corresponding keyword representing the physiological state information of human body according to the one or more human body characteristic indicators. The output module is used to output the human body characteristic index and the key words. It includes the key words of Qi and blood state information, the key words of viscera state information, the key words of Qi and blood state information, etc. The system can be used for serious disease screening, chronic disease management, and risk early warning.