7 February 2020 in IET Biometrics
One of the major challenges in ocular biometrics is the cross‐spectral scenario, i.e. how to match images acquired in different wavelengths. This study designs and extensively evaluates cross‐spectral ocular verification methods using well known deep learning representations based on the iris and periocular regions. Using as inputs, the bounding boxes of non‐normalised iris–periocular regions, the authors fine‐tune convolutional neural network models, originally trained for face recognition. On the basis of the experiments carried out in two publicly available cross‐spectral ocular databases, they report results for intra‐spectral and cross‐spectral scenarios, with the best performance being observed when fusing ResNet‐50 deep representations from both the periocular and iris regions. When compared to the state of the art, they observed that the proposed solution consistently reduces the equal error rate values by 90%/93%/96% and 61%/77%/83% on the cross‐spectral scenario and in the PolyU bi‐spectral and cross‐eye–cross‐spectral datasets. Finally, they evaluate the effect that the ‘deepness’ factor of feature representations has in recognition effectiveness, and based on a subjective analysis of the most problematic pairwise comparisons – they point out further directions for this field of research.
21 October 2022 in IEEE Transactions on Information Forensics and Security
Bias and fairness of biometric algorithms have been key topics of research in recent years, mainly due to the societal, legal and ethical implications of potentially unfair decisions made by automated decision-making models. A considerable amount of work has been done on this topic across different biometric modalities, aiming at better understanding the main sources of algorithmic bias or devising mitigation measures. In this work, we contribute to these efforts and present the first study investigating bias and fairness of sclera segmentation models. Although sclera segmentation techniques represent a key component of sclera-based biometric systems with a considerable impact on the overall recognition performance, the presence of different types of biases in sclera segmentation methods is still underexplored. To address this limitation, we describe the results of a group evaluation effort (involving seven research groups), organized to explore the performance of recent sclera segmentation models within a common experimental framework and study performance differences (and bias), originating from various demographic as well as environmental factors. Using five diverse datasets, we analyze seven independently developed sclera segmentation models in different experimental configurations. The results of our experiments suggest that there are significant differences in the overall segmentation performance across the seven models and that among the considered factors, ethnicity appears to be the biggest cause of bias. Additionally, we observe that training with representative and balanced data does not necessarily lead to less biased results. Finally, we find that in general there appears to be a negative correlation between the amount of bias observed (due to eye color, ethnicity and acquisition device) and the overall segmentation performance, suggesting that advances in the field of semantic segmentation may also help with mitigating bias.
10 May 2025 in Neural Processing Letters
Accurate extraction of the Region of Interest is critical for successful ocular region-based biometrics. In this direction, we propose a new context-based segmentation approach, entitled Ocular Region Context Network (ORCNet), introducing a specific loss function, i.e., the Punish Context Loss (PC-Loss). The PC-Loss punishes the segmentation losses of a network by using a percentage difference value between the ground truth and the segmented masks. We obtain the percentage difference by taking into account Biederman’s semantic relationship concepts, in which we use three contexts (semantic, spatial, and scale) to evaluate the relationships of the objects in an image. Our proposal achieved promising results in the evaluated scenarios—iris, sclera, and ALL (iris + sclera) segmentations—, outperforming the literature baseline techniques. The ORCNet with ResNet-152 outperforms the best baseline (EncNet with ResNet-152) on average by 2.\(27\%\), 28.\(26\%\) and 6.\(43\%\) in terms of F-Score, Error Rate and Intersection Over Union, respectively. We also provide (for research purposes) 3191 manually labeled masks for the MICHE-I database, as another contribution of our work.
12 February 2020 in arXiv
The iris pattern has significantly improved the biometric recognition field due to its high level of stability and uniqueness. Such physical feature has played an important role in security and other related areas. However, presentation attacks, also known as spoofing techniques, can be used to bypass the biometric system with artifacts such as printed images, artificial eyes, and textured contact lenses. To improve the security of these systems, many liveness detection methods have been proposed, and the first Internacional Iris Liveness Detection competition was launched in 2013 to evaluate their effectiveness. In this paper, we propose a hyperparameter tuning of the CASIA algorithm, submitted by the Chinese Academy of Sciences to the third competition of Iris Liveness Detection, in 2017. The modifications proposed promoted an overall improvement, with an 8.48% Attack Presentation Classification Error Rate (APCER) and 0.18% Bonafide Presentation Classification Error Rate (BPCER) for the evaluation of the combined datasets. Other threshold values were evaluated in an attempt to reduce the trade-off between the APCER and the BPCER on the evaluated datasets and worked out successfully.