29 October 2007 in IEEE Transactions on Power Systems
This paper presents a practical approach for supplementary control of high voltage direct current (HVDC) system to damp subsynchronous oscillation (SSO) involving HVDC converters and turbine-generator shaft systems. A novel eigenvalue analysis (NEA) program, HVDC system modeling to consider steady-state and dynamic conditions in a combined ac/dc system, and an appropriate control scheme have been utilized. The design method proposed facilitates the design of a subsynchronous oscillation damping controller (SODC) to provide positive damping torque for the dominant torsional mode in combined ac/dc systems. The suggested SODC design method has been applied to an ac/dc system to verify its practicality using the EMTDC simulation program.
12 February 2004 in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
We report that NH3 ambient thermal annealing is a promising method for recovering the dry- etch-induced damage on Mg-doped GaN surfaces. The surface electrical properties of dry-etched Mg-doped GaN can be fully recovered by thermal annealing using NH3 as an ambient gas at temperatures above 900 °C. The complete recovery of sheet hole concentration in dry-etched Mg-doped GaN can be attributed to a reduction in excess nitrogen vacancies in the damaged surface region by reactive nitrogen atoms supplied during NH3 ambient thermal annealing.
8 May 2015 in IEEE Transactions on Energy Conversion
This paper proposes a new simplified model of a doubly fed induction generator (DFIG) that is integrated with a rotor-side converter for studies of large-scale transient stability. This model accurately considers the rotor field dynamics of an induction generator to yield simulation results that are more accurate in terms of voltage stability, as well as angle stability. The purpose of this paper is to provide a simple but effective DFIG model for the study of large-scale transient stability, and to examine the important aspects of rotor voltage and rotor slip power. This new simplified DFIG model with an electric/turbine control system was tested against a six-machine and 23-bus system, and the responses obtained in case studies of transient stability were compared with those of a PSS/E program. Finally, the proposed DFIG model was also validated by comparing the simulation results for a single-machine and infinite-bus system with those of PSCAD/EMTDC.
8 December 2017 in IEEE Transactions on Power Systems
Frequency drops and the high ambient temperature cause a decrease in airflow and an increase in the exhaust gas temperature of a gas turbine (GT). Correct modeling of these conditions under heavily loaded conditions is very important. Otherwise, the simulated maximum output of GT may be significantly higher than the real one and estimation of frequency responsive reserve may be gravely erroneous. This paper describes the modeling and simulation of a heavy-duty GT operating under temperature control to study its impact on power system stability. For the practical simulation, a simple logic was added to the temperature reference parameter to represent the GT under the temperature control mode in steady-state conditions in the popular Rowen GT model, and the bumpless tracking logic was considered in the proportional-integral temperature controller. For three widely used GT models, GAST, GAST2A, and GGOV1, the effect of the temperature control loop on the transient stability are simply reviewed by applying the three-phase fault. Finally, the impact of GT under temperature control operation on frequency stability was analyzed using the proposed GT model with the determined model parameters of a practical GT system with 341 MVA during frequency drop against a six-machine, 23-bus system
24 November 2017 in IEEE Transactions on Energy Conversion
The proposed algorithm is based on the discrete Fourier transform (DFT) and a software-based synchronous sampling technique that is locked to the power system frequency using reconfigurable field-programmable gate arrays (FPGAs). The main purposes of this paper are to provide a new method of recording the high-resolution rotor angle of a synchronous machine and a practical method for deriving more accurate d-q axis synchronous machine parameters. An FPGA is used in realizing the rotor-angle transducer and it simultaneously detects the frequency of the generator terminal voltage. The DFT algorithm is combined with an interpolation technique that downsamples the high-frequency sampled data using the measured power system frequency. This paper also describes a practical method for determining synchronous machine model parameters. The proposed algorithm for recording the generator dynamics was implemented using Labview, Real-Time PXI target and the FPGA, and was applied to generator testing of a 1,205 MVA thermal power unit. Its synchronous machine parameters were also derived using the recorded rotor angle.
12 February 2003 in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
The electrical and optical characteristics of GaN:Mg irradiated by a pulsed KrF (248 nm) excimer laser have been studied. When an as-grown Mg-doped GaN film was irradiated by an excimer laser at an energy density of 590 mJ/cm2 in a nitrogen atmosphere, the hole concentration was drastically increased up to 4.42×1017 cm−3. Furthermore, a GaN:Mg thin film, which was treated by laser irradiation following a conventional rapid thermal annealing process, showed a very high hole concentration of 9.42×1017 cm−3. The GaN:Mg samples, which were activated in a nitrogen ambient by the KrF excimer laser irradiation, showed two photoluminescence peaks at 2.95 eV and 2.7 eV. The intensities of both photoluminescence peaks were increased with increasing laser energy density and number of pulses. The changes in photoluminescence peaks depending on the laser energy density further suggest that the pulsed KrF excimer laser irradiation dissociates the Mg–H complexes and allows the hydrogens to diffuse out, thus significantly enhancing the p-type conductivity of GaN:Mg.