From the Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, St Louis, MO 63110 (M.N., M.J.H., F.W.P., D.H.B., M.Z., C.R., V.M.M.); and Division of Emergency/Trauma Radiology, McMaster University, Hamilton General Hospital, Hamilton, Ontario, Canada (M.N.P.).
Auto-generated profile, based on publicly available information
Frank W. Petraglia
From the Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, St Louis, MO 63110 (M.N., M.J.H., F.W.P., D.H.B., M.Z., C.R., V.M.M.); and Division of Emergency/Trauma Radiology, McMaster University, Hamilton General Hospital, Hamilton, Ontario, Canada (M.N.P.).
This Technical Report describes new methods of transcranial magnetic stimulation (TMS) in non-human primates. By combining single neuron recording with a modified TMS coil with focused stimulation in alert macaques, the authors show that this method can reduce stimulation artifact and allow investigation into the neuronal mechanisms of TMS. Transcranial magnetic stimulation (TMS) is a widely used, noninvasive method for stimulating nervous tissue, yet its mechanisms of effect are poorly understood. Here we report new methods for studying the influence of TMS on single neurons in the brain of alert non-human primates. We designed a TMS coil that focuses its effect near the tip of a recording electrode and recording electronics that enable direct acquisition of neuronal signals at the site of peak stimulus strength minimally perturbed by stimulation artifact in awake monkeys (Macaca mulatta). We recorded action potentials within ∼1 ms after 0.4-ms TMS pulses and observed changes in activity that differed significantly for active stimulation as compared with sham stimulation. This methodology is compatible with standard equipment in primate laboratories, allowing easy implementation. Application of these tools will facilitate the refinement of next generation TMS devices, experiments and treatment protocols.
1 January 2016 in Neuromodulation: Technology at the Neural Interface
Objective: Spinal cord stimulation (SCS) has been proven effective for multiple chronic pain syndromes. Over the past 40 years of use, the complication rates of SCS have been well defined in the literature; however, the incidence of one of the most devastating complications, spinal cord injury (SCI), remains largely unknown. The goal of the study was to quantify the incidence of SCI in both percutaneous and paddle electrode implantation. Methods: We conducted a retrospective review of the Thomson Reuter’s MarketScan database of all patients that underwent percutaneous or paddle SCS implantation from 2000 to 2009. The main outcome measures of the study were the incidence of SCI and spinal hematoma within 30 days following operation. Results: Overall 8326 patients met inclusion criteria for the study (percutaneous: 5458 vs. paddle: 2868). The overall incidence of SCI was 177 (2.13%) (percutaneous: 128 (2.35%) vs. paddle: 49 (1.71%), p = 0.0556). The overall incidence of spinal hematoma was 59 (0.71%) (percutaneous: 41 (0.75%) vs. paddle: 18 (0.63%), p = 0.5230). Conclusion: Our study shows that the overall incidence of SCI in SCS is low (2.13%), supporting that SCS is a safe procedure. No significant difference was found in the rates of SCI or spinal hematoma between the percutaneous and paddle groups. Further studies are needed to characterize the mechanisms of SCI in SCS and long-term outcomes in these patients.
16 November 2015 in Neuromodulation: Technology at the Neural Interface
Timely identification of injuries secondary to penetrating abdominopelvic trauma can prevent poor patient outcomes, and radiologists should be familiar with the kinetics of penetrating objects, the... Penetrating abdominopelvic trauma usually results from abdominal cavity violation from a firearm injury or a stab wound and is a leading cause of morbidity and mortality from traumatic injuries. Pe...