Department of Micro/Nano Electronics, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
Auto-generated profile, based on publicly available information
Yijun Liu
Department of Micro/Nano Electronics, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
In vitro organoid models, typically defined as 3D multicellular aggregates, have been extensively used as a promising tool in drug screening, disease progression research, and precision medicine. Combined with advanced microfluidics technique, organoid-on-a-chip can flexibly replicate in vivo organs within the biomimetic physiological microenvironment by accurately regulating different parameters, such as fluid conditions and concentration gradients of biochemical factors. Since engineered organ reconstruction has opened a new paradigm in biomedicine, innovative approaches are increasingly required in micro-nano fabrication, tissue construction, and development of pharmaceutical products. In this Perspective review, the advantages and characteristics of organoid-on-a-chip are first introduced. Challenges in current organoid culture, extracellular matrix building, and device manufacturing techniques are subsequently demonstrated, followed by potential alternative approaches, respectively. The future directions and emerging application scenarios of organoid-on-a-chip are finally prospected to further satisfy the clinical demands.
Planar semiconductor InGaAs/InP single photon avalanche diodes with high responsivity and low dark count rate are preferred single photon detectors in near-infrared communication. However, even with well-designed structures and well-controlled operational conditions, the performance of InGaAs/InP SPADs is limited by the inherent characteristics of avalanche process and the growth quality of InGaAs/InP materials. It is difficult to ensure high detection efficiency while the dark count rate is controlled within a certain range at present. In this paper, we fabricated a device with a thick InGaAs absorption region and an anti-reflection layer. The quantum efficiency of this device reaches 83.2%. We characterized the single-photon performance of the device by a quenching circuit consisting of parallel-balanced InGaAs/InP single photon detectors and single-period sinusoidal pulse gating. The spike pulse caused by the capacitance effect of the device is eliminated by using the characteristics of parallel balanced common mode signal elimination, and the detection of small avalanche pulse amplitude signal is realized. The maximum detection efficiency is 55.4% with a dark count rate of 43.8 kHz and a noise equivalent power of 6.96 × 10−17 W/Hz1/2 at 247 K. Compared with other reported detectors, this SPAD exhibits higher SPDE and lower noise-equivalent power at a higher cooling temperature.
Targeted microrobotic delivery within the circulatory system holds significant potential for medical theranostic applications. Existing delivery strategies of microrobots encounter challenges such as slow speed, limited navigation control, and dispersal under dynamic flow conditions. Furthermore, within the realm of microrobots, in vitro testing platforms often lack essential biological microenvironments, while in vivo studies conducted on animal models are constrained by limited detection resolution. In this study, we propose a multi-level magnetic delivery strategy that integrates a tethered microrobotic guidewire and untethered swimming microrobots. The amalgamation compensates for their inherent constraints, ensuring a robust and highly efficient delivery of microrobots under complex physiological conditions over extensive distances. Concurrently, a hierarchical vascular network encompassing engineered arteries/veins and capillary networks was constructed by integrating vasculogenesis and endothelial cell (EC) lining strategies, thereby providing an in vivo-like testing platform for microrobots. Experimental evidence demonstrates that the flexible microrobotic guidewire can be precisely directed to any entrance of the second-tier branches, with its inner lumen providing an “express lane” for rapid passage of microrobots through complex fluidic environments without direct contact. After release, dynamically assembled swarms could effectively locomote on the micro-topography of the EC-lined channel surface without becoming trapped and congregate within specified regions inside capillary lumens when guided collectively by a biologically safe magnetic field. Additionally, the superparamagnetic capabilities of microrobotic swarms ensure their dissolution into monodispersed entities upon withdrawal of the magnetic field, mitigating the risk of intravascular thrombosis. The hierarchical vascularized organ-on-a-chip platform establishes a comprehensive testing platform that integrates imaging, control, and a functional 3D microvascular environment, thereby enhancing its suitability for microrobotic applications encompassing targeted drug delivery, thrombus ablation, sensing and diagnosis, etc.
We developed a multifunctional cardiac microphysiological system on transparent electrodes, enabling simultaneous electrical signal monitoring and optical observations of cardiac tissue, holding promise for applications in cardiac drug development.
VitroOrganoSphere (VOS) is an automated droplet platform that streamlines organoid encapsulation, detection, sorting, and dispensing for efficient, low-reagent screening of patient-derived samples.