Samuel M. Stavis

Samuel M. Stavis

Auto-generated profile, based on publicly available information

Samuel M. Stavis

Microsystems and Nanotechnology Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2018 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
SSSamuel M. Stavis
Samuel M. Stavis
JFJeffrey A. Fagan
Jeffrey A. Fagan
MSMichael Stopa
Michael Stopa
JLJ. Alexander Liddle
J. Alexander Liddle

17 August 2017 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
ABA. L. Balk
A. L. Balk
KKK-W. Kim
K-W. Kim
DPD. T. Pierce
D. T. Pierce
MSM. D. Stiles
M. D. Stiles
JUJ. Unguris
J. Unguris
SSS. M. Stavis
S. M. Stavis
Magneto-optical Kerr effect (MOKE) microscopy measurements of magnetic bubble domains demonstrate that Ar+ irradiation around 100 eV can tune the Dzyaloshinskii-Moriya interaction (DMI) in Pt/Co/Pt trilayers. Varying the irradiation energy and dose changes the DMI sign and magnitude separately from the magnetic anisotropy, allowing tuning of the DMI while holding the coercive field constant. This simultaneous control emphasizes the different physical origins of these effects. To accurately measure the DMI, we propose and apply a physical model for a poorly understood peak in domain wall velocity at zero in-plane field. The ability to tune the DMI with the spatial resolution of the Ar+ irradiation enables new fundamental investigations and technological applications of chiral nanomagnetics.

11 July 2018 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
CCCraig R. Copeland
Craig R. Copeland
JGJon Geist
Jon Geist
CMCraig D. McGray
Craig D. McGray
VAVladimir Aksyuk
Vladimir Aksyuk
JLJ. Alexander Liddle
J. Alexander Liddle
SSSamuel M. Stavis
Samuel M. Stavis
The common assumption that precision is the limit of accuracy in localization microscopy and the typical absence of comprehensive calibration of optical microscopes lead to a widespread issue—overconfidence in measurement results with nanoscale statistical uncertainties that can be invalid due to microscale systematic errors. In this article, we report a comprehensive solution to this underappreciated problem. We develop arrays of subresolution apertures into the first reference materials that enable localization errors approaching the atomic scale across a submillimeter field. We present novel methods for calibrating our microscope system using aperture arrays and develop aberration corrections that reach the precision limit of our reference materials. We correct and register localization data from multiple colors and test different sources of light emission with equal accuracy, indicating the general applicability of our reference materials and calibration methods. In a first application of our new measurement capability, we introduce the concept of critical-dimension localization microscopy, facilitating tests of nanofabrication processes and quality control of aperture arrays. In a second application, we apply these stable reference materials to answer open questions about the apparent instability of fluorescent nanoparticles that commonly serve as fiducial markers. Our study establishes a foundation for subnanometer localization accuracy in widefield optical microscopy.

1 March 2016 in Applied Physics Reviews
Verified
Journal Article
Open access
PDF file
PMP. P. Mathai
P. P. Mathai
JLJ. A. Liddle
J. A. Liddle
SSS. M. Stavis
S. M. Stavis
The trajectories of nanoscale particles through microscale environments record useful information about both the particles and the environments. Optical microscopes provide efficient access to this information through measurements of light in the far field from nanoparticles. Such measurements necessarily involve trade-offs in tracking capabilities. This article presents a measurement framework, based on information theory, that facilitates a more systematic understanding of such trade-offs to rationally design tracking systems for diverse applications. This framework includes the degrees of freedom of optical microscopes, which determine the limitations of tracking measurements in theory. In the laboratory, tracking systems are assemblies of sources and sensors, optics and stages, and nanoparticle emitters. The combined characteristics of such systems determine the limitations of tracking measurements in practice. This article reviews this tracking hardware with a focus on the essential functions of nanoparticles as optical emitters and microenvironmental probes. Within these theoretical and practical limitations, experimentalists have implemented a variety of tracking systems with different capabilities. This article reviews a selection of apparatuses and techniques for tracking multiple and single particles by tuning illumination and detection, and by using feedback and confinement to improve the measurements. Prior information is also useful in many tracking systems and measurements, which apply across a broad spectrum of science and technology. In the context of the framework and review of apparatuses and techniques, this article reviews a selection of applications, with particle diffusion serving as a prelude to tracking measurements in biological, fluid, and material systems, fabrication and assembly processes, and engineered devices. In so doing, this review identifies trends and gaps in particle tracking that might influence future research.

25 January 2012 in Macromolecules
Verified
Journal Article
Closed access
ESElizabeth A. Strychalski
Elizabeth A. Strychalski
JGJon Geist
Jon Geist
MGMichael Gaitan
Michael Gaitan
LLLaurie E. Locascio
Laurie E. Locascio
SSSamuel M. Stavis
Samuel M. Stavis

11 August 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SSSamuel M. Stavis
Samuel M. Stavis
JGJon Geist
Jon Geist
MGMichael Gaitan
Michael Gaitan
A nanofluidic technology for the on-chip size separation and metrology of nanoparticles is demonstrated. A nanofluidic channel was engineered with a depth profile approximated by a staircase function. Numerous stepped reductions in channel depth were used to separate a bimodal mixture of nanoparticles by nanofluidic size exclusion. Epifluorescence microscopy was used to map the size exclusion positions of individual nanoparticles to corresponding channel depths, enabling measurement of the nanoparticle size distributions and validation of the size separation mechanism.