Ashutosh Sahu

Ashutosh Sahu

Auto-generated profile, based on publicly available information

Ashutosh Sahu

Department of Mechanical Engineering, Chaitanya Bharathi Institute of Technology, Hyderabad, India

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in Materials Science and Engineering: A
Verified
Journal Article
Closed access
TTTony Thomas
Tony Thomas
CZCheng Zhang
Cheng Zhang
ASAshutosh Sahu
Ashutosh Sahu
PNPranjal Nautiyal
Pranjal Nautiyal
ALArchana Loganathan
Archana Loganathan
AAArvind Agarwal
Arvind Agarwal

15 November 2023 in Advanced Engineering Materials
Verified
Journal Article
Closed access
ASAshutosh Sahu
Ashutosh Sahu
RMRam Sajeevan Maurya
Ram Sajeevan Maurya
TLTapas Laha
Tapas Laha

8 September 2025 in Applied Surface Science
Verified
Journal Article
Closed access
ASAshutosh Sahu
Ashutosh Sahu
MTManeesha Tewari
Maneesha Tewari
YAYarramilli Vamsi A
Yarramilli Vamsi A
SRSanjay Rai
Sanjay Rai
NMNiroj Maharjan
Niroj Maharjan
Ayan BhowmikAyan Bhowmik
Ayan Bhowmik

12 June 2026 in Applied Surface Science
Verified
Journal Article
Closed access
SKSudha Kumari
Sudha Kumari
SDSovan Dey
Sovan Dey
ASAshutosh Sahu
Ashutosh Sahu
NGNitya Nand Gosvami
Nitya Nand Gosvami
SKSachin Kumar
Sachin Kumar
Ayan BhowmikAyan Bhowmik
Ayan Bhowmik

18 March 2025 in Zastita materijala
Verified
Journal Article
Open access
PDF file
NKNishant Kumar
Nishant Kumar
ASAshutosh Sahu
Ashutosh Sahu
INI.M. Noor
I.M. Noor
PSPramod Kumar Singh
Pramod Kumar Singh
LSLavish Kumar Singh
Lavish Kumar Singh
Polypropylene fibers possess certain characteristics that make them an ideal counterpart to attain explicit advantages when used for building works, more specifically, when added to concrete. In this investigation, polypropylene fibers were added by weight of cement (0.25%, 0.5%, and 0.75%) in M20 grade of concrete and their impact on workability, compressive strength, and flexural strength were assessed and analyzed. The slump test revealed that as the polypropylene fiber loading in the concrete mix was increased, the workability of the mixture continued to decrease; the workability decreased by 11.11%, 19.44%, and 45.83% upon the addition of 0.25 %, 0.5%, and 0.75% fibers respectively in the concrete. The compressive strength, as well as the flexural strength of the concrete, increased monotonously with an increase in the curing time and fiber loading. For instance, in the case of acidic water curing, the compressive strength enhanced from 19.08 MPa to 22.85 MPa upon increasing the fiber content from 0.25% to 0.75%. Adding 0.25% polypropylene fiber resulted in an increase in the flexural strength of conventional concrete mix by 15.78% and 10.29% when cured in normal water for 28 days and 56 days, respectively. Both the compressive and flexural strength of the samples cured in normal water was found to be higher than the samples cured in acidic water and it was observed that the fibre-reinforced concretes were more resistant to acids than the normal unreinforced concrete.