Marco Gobbo

Marco Gobbo

Auto-generated profile, based on publicly available information

Marco Gobbo

Dipartimento di Fisica “Giuseppe Occhialini”, Università degli Studi di Milano-Bicocca, Milano, Italy

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2025 in Physical Review Letters
Verified
Journal Article
Open access
BABradley Alpert
Bradley Alpert
MBM. Balata
M. Balata
DBD. T. Becker
D. T. Becker
DBD. A. Bennett
D. A. Bennett
MBMatteo Borghesi
Matteo Borghesi
LVL. R. Vale
L. R. Vale
The determination of the absolute neutrino mass scale remains a fundamental open question in particle physics, with profound implications for both the standard model and cosmology. Direct kinematic measurements, independent of model-dependent assumptions, provide the most robust approach to address this challenge. Here we present the most stringent upper bound on the effective electron neutrino mass ever obtained with a calorimetric measurement of the electron capture decay of Ho 163 . The HOLMES experiment employs an array of ion-implanted transition-edge sensor (TES) microcalorimeters, achieving an average energy resolution of 6 eV FWHM with a scalable, multiplexed readout technique. With a total of 7 × 10 7 decay events recorded over two months and a Bayesian statistical analysis, we derive an upper limit of m β < 27 eV / c 2 at 90% credibility. These results validate the feasibility of Ho 163 calorimetry for next-generation neutrino mass experiments and demonstrate the potential of a scalable TES-based microcalorimetric technique to push the sensitivity of direct neutrino mass measurements beyond the current state of the art.

14 November 2025 in IEEE Transactions on Quantum Engineering
Verified
Journal Article
Open access
RMRoberto Moretti
Roberto Moretti
DLDanilo Labranca
Danilo Labranca
PCPietro Campana
Pietro Campana
RCRodolfo Carobene
Rodolfo Carobene
MGMarco Gobbo
Marco Gobbo
Andrea GiacheroAndrea Giachero
Andrea Giachero
This study presents the design, simulation, and experimental characterization of a superconducting transmon qubit circuit prototype for potential applications in dark matter detection experiments. We describe a planar circuit design featuring two noninteracting transmon qubits, one with fixed frequency and the other flux tunable. Finite-element simulations were employed to extract key Hamiltonian parameters and optimize component geometries. The qubit was fabricated and then characterized at 20 mK, allowing for a comparison between simulated and measured qubit parameters. Good agreement was found for transition frequencies and anharmonicities (within 1% and 10%, respectively) while coupling strengths exhibited larger discrepancies (30%). We discuss potential causes for measured coherence times falling below expectations ($T_{1}\sim \,$1–2 μs) and propose strategies for future design improvements. Notably, we demonstrate the application of a hybrid 3D–2D simulation approach for energy participation ratio evaluation, yielding a more accurate estimation of dielectric losses. This work represents an important first step in developing planar quantum nondemolition single-photon counters for dark matter searches, particularly for axion and dark photon detection schemes.

30 September 2025 in The European Physical Journal C
Verified
Journal Article
Open access
PDF file
DBDouglas Bennett
Douglas Bennett
MBMatteo Borghesi
Matteo Borghesi
PCPietro Campana
Pietro Campana
RCRodolfo Carobene
Rodolfo Carobene
GCGiancarlo Ceruti
Giancarlo Ceruti
JUJoel Ullom
Joel Ullom
We present a detailed investigation of the performance of transition-edge sensor (TES) microcalorimeters with $$^{163}$$ 163 Ho atoms embedded by ion implantation, as part of the HOLMES experiment aimed at neutrino mass determination. The inclusion of $$^{163}$$ 163 Ho atoms introduces an excess heat capacity due to a pronounced Schottky anomaly, which can affect the detector’s energy resolution, signal height, and response time. We fabricated TES arrays with varying levels of $$^{163}$$ 163 Ho activity and characterized their performance in terms of energy resolution, decay time constants, and heat capacity. The intrinsic energy resolution was found to degrade with increasing $$^{163}$$ 163 Ho activity, consistent with the expected scaling of heat capacity. From the analysis, we determined the specific heat capacity of $$^{163}$$ 163 Ho to be $$(2.9 \pm 0.4 \mathrm {(stat)} \pm 0.7 \mathrm {(sys)})$$ ( 2.9 ± 0.4 ( stat ) ± 0.7 ( sys ) ) J/K/mol at $$(94 \pm 1)$$ ( 94 ± 1 ) mK, close to the literature values for metallic holmium. No additional long decay time constants correlated with $$^{163}$$ 163 Ho activity were observed, indicating that the excess heat capacity does not introduce weakly coupled thermodynamic systems. These results suggest that our present TES microcalorimeters can tolerate $$^{163}$$ 163 Ho activities up to approximately 5 Bq, with only about a factor of three degradation in performance compared to detectors without $$^{163}$$ 163 Ho. For higher activities, reducing the TES transition temperature is necessary to maintain or improve the energy resolution. These findings provide critical insights for optimizing TES microcalorimeters for future neutrino mass experiments and other applications requiring embedded radioactive sources. The study also highlights the robustness of TES technology in handling limited amounts of implanted radionuclides while maintaining high-resolution performance.

23 March 2026 in Journal of High Energy Physics
Verified
Journal Article
Open access
FAF. Ahrens
F. Ahrens
BABradley Alpert
Bradley Alpert
DBD. T. Becker
D. T. Becker
DBD. A. Bennett
D. A. Bennett
EBE. Bogoni
E. Bogoni
LVL. R. Vale
L. R. Vale
A bstract: We present a comprehensive phenomenological analysis of the calorimetric electron capture (EC) decay spectrum of 163 Ho as measured by the HOLMES experiment. Using high-statistics data, we unfold the instrumental energy resolution from the measured spectrum and model it as a sum of Breit-Wigner resonances and shake-off continua, providing a complete set of parameters for each component. Our approach enables the identification and tentative interpretation of all observed spectral features, including weak and overlapping structures, in terms of atomic de-excitation processes. We compare our phenomenological model with recent ab initio theoretical calculations, finding good agreement for both the main peaks and the spectral tails, despite the limitations of current theoretical and experimental precision. The model delivers an accurate description of the endpoint region, which is crucial for neutrino mass determination, and allows for a realistic treatment of backgrounds such as pile-up and tails of low-energy components. Furthermore, our decomposition facilitates the generation of Monte Carlo toy spectra for sensitivity studies and provides a framework for investigating systematic uncertainties related to solid-state and detector effects. This work establishes a robust foundation for future calorimetric neutrino mass experiments employing 163 Ho, supporting both data analysis and experimental design.

14 October 2026 in The European Physical Journal Plus
Verified
Journal Article
Open access
PDF file
DBD. A. Bennett
D. A. Bennett
MBMatteo Borghesi
Matteo Borghesi
PCP. Campana
P. Campana
RCRodolfo Carobene
Rodolfo Carobene
ACA. Cattaneo
A. Cattaneo
JUJ. N. Ullom
J. N. Ullom
We present the realization of a prototype of a compact, switchable electron source operating at cryogenic temperatures, demonstrated at energies ranging from 100 eV to 300 eV, and conceptually extendable to an arbitrary energy range. The electrons are produced via photoelectric emission, induced by a LED illuminating two 400-nm-thick commercial aluminum layers inside a cryostat, and are subsequently accelerated by a voltage of up to 300 V. Detection is carried out with an array of transition-edge sensor (TES) microcalorimeters designed for X-ray detectors, where we successfully observe signals consistent with electrons produced at the source at rates of $$\gtrsim$$ ≳ 1 Hz and with an efficiency of $$\gtrsim 10^{-14}\ e^-/\gamma$$ ≳ 10 - 14 e - / γ .

13 June 2024 in European Journal of Physics
Verified
Journal Article
Open access
PDF file
PCPietro Campana
Pietro Campana
RCRodolfo Carobene
Rodolfo Carobene
ECEleonora Cipelli
Eleonora Cipelli
MGMarco Gobbo
Marco Gobbo
APAurora Perego
Aurora Perego
DVDavide Vertemati
Davide Vertemati
This paper presents a new laboratory activity aimed at developing knowledge and expertise in microwave applications at cryogenic temperatures. The experience focuses on the detection of infrared photons through microwave kinetic inductance detectors. The experimental setup, theoretical concepts, and activities involved are detailed, highlighting the skills and knowledge gained through the experience. This experiment is designed for graduate students in the field of quantum technologies.