This paper introduces a new modular cascaded multilevel inverter (MLI) which is composed of a cascaded connection of submodules (SMs). The combination of basic cells (BCs) with polarity changer H-Bridge produces the SMs, which is the basis of the introduced inverter. Owing to its high modularity, the proposed inverter can be extended to reach higher voltage levels. Hence, two extensions are suggested: 1) Extension based on cascading more BCs within each SM, and 2) Extension based on cascading more SMs. Using a set of algorithms, the magnitude of DC voltage sources is determined to synthesize the proper AC side voltage waveform. Furthermore, the proposed topology is optimized in different ways to achieve the desired purposes, such as maximizing the number of voltage levels, minimizing the number of switches and DC sources, and providing the least total standing voltage on the switches. Therefore, in each of the mentioned optimization goals, the optimal structure is obtained. A prototype of the presented MLI is defined and its performance is verified through several simulation studies in MATLAB/Simulink and experimental tests. Besides, a comprehensive comparison is made with the best performance of the existing alternatives to demonstrate the merits and superiorities of the proposed MLI.
12 June 2020 in International Transactions on Electrical Energy Systems
This paper presents a new structure for a quasi‐resonant switched capacitor multilevel inverter. This structure offers multiple features of the conventional multilevel structures. Moreover, regarding the provided output voltage levels, the proposed structure exploits a new quasi‐resonant basic module which helps to diminish circuit cost and complexity using fewer power components. In the proposed structure, the balancing of capacitors voltages is achieved by series and parallel connection with the voltage source and without the need to employ a complicated control system. In order to obtain higher voltage levels at the inverter ac side, a developed H‐bridge is used in which the basic module is extended horizontally in separate cells on either side. Through a quasi‐resonant inductor deployment in the basic module, current spikes of capacitors are filtered which overwhelms decreasing of capacitor value and also lengthening the capacitor lifetime besides decreasing electromagnetic interference (EMI). Coupled with extensive simulation studies, experimental analyses are conducted to validate the performance of the proposed 17‐level inverter.
In this study, a method is presented for the detection of open-circuit fault (OCF) in the power switches of nested neutral point clamped (NNPC) inverter for the first time. Using this method, the occurrence and location of OCF are determined in less than one fundamental period. In the proposed method, not only the output voltage and current but also the voltages of capacitors are used for the identification of the OCFs in NNPC. Besides, the effect of each switch OCF on the output voltage and current and also capacitors voltage is analyzed and based on this analysis, an OCF diagnosis scheme is presented. The expected values of capacitors voltages and output voltage and current are compared in each switching state with the measured ones, and the deviation of the measured and the expected values are used for OCF localization. Moreover, for verifying the performance and feasibility of the introduced method, the level-shifted pulse width modulation (LS-PWM) is applied to NNPC, and the OCF detection results are presented in the MATLAB/SIMULINK environment.
7 March 2025 in IEEE Transactions on Power Electronics
Reliability of capacitors is a critical factor in ensuring the optimal performance of modular multilevel converters (MMC), which can be enhanced through health status monitoring and predictive maintenance. However, existing literature on MMC submodule capacitor condition monitoring primarily focuses on capacitance while overlooking the influences of the equivalent series resistance (ESR). Furthermore, the second problem is that the ESR is assumed to be negligible in the capacitance estimation. The assumption is not always valid, and may introduce significant errors in capacitance estimation. To improve existing condition monitoring methods, this article uses a capacitor–voltage equation to model the coupling effect of capacitance and ESR, based on which, particle swarm optimization is used to update the estimations of capacitance and ESR together. The proposed method offers more reliable health monitoring with two health indicators and derives a better estimation accuracy when the ESR is not negligible. Furthermore, to ensure the existence of the global optimal solution, the convexity of the data-driven problem is studied. The effectiveness and feasibility of the proposed method are validated with simulations, experiments, and an open-source dataset.