Maryam Afzali

Maryam Afzali

Auto-generated profile, based on publicly available information

Maryam Afzali

Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine University of Leeds Leeds UK

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Journal of Neuroscience Methods
Verified
Journal Article
Open access
MAMaryam Afzali
Maryam Afzali
TPTomasz Pieciak
Tomasz Pieciak
SNSharlene Newman
Sharlene Newman
EGEleftherios Garyfallidis
Eleftherios Garyfallidis
EÖEvren Özarslan
Evren Özarslan
DJDerek K Jones
Derek K Jones
Diffusion MRI is a non-invasive technique to study brain microstructure. Differences in the microstructural properties of tissue, including size and anisotropy, can be represented in the signal if the appropriate method of acquisition is used. However, to depict the underlying properties, special care must be taken when designing the acquisition protocol as any changes in the procedure might impact on quantitative measurements. This work reviews state-of-the-art methods for studying brain microstructure using diffusion MRI and their sensitivity to microstructural differences and various experimental factors. Microstructural properties of the tissue at a micrometer scale can be linked to the diffusion signal at a millimeter-scale using modeling. In this paper, we first give an introduction to diffusion MRI and different encoding schemes. Then, signal representation-based methods and multi-compartment models are explained briefly. The sensitivity of the diffusion MRI signal to the microstructural components and the effects of curvedness of axonal trajectories on the diffusion signal are reviewed. Factors that impact on the quality (accuracy and precision) of derived metrics are then reviewed, including the impact of random noise, and variations in the acquisition parameters (i.e., number of sampled signals, b-value and number of acquisition shells). Finally, yet importantly, typical approaches to deal with experimental factors are depicted, including unbiased measures and harmonization. We conclude the review with some future directions and recommendations on this topic.

23 February 2022 in NeuroImage
Verified
Journal Article
Open access
QFQiuyun Fan
Qiuyun Fan
CECornelius Eichner
Cornelius Eichner
MAMaryam Afzali
Maryam Afzali
LMLars Mueller
Lars Mueller
CTChantal M.W. Tax
Chantal M.W. Tax
SHSusie Y. Huang
Susie Y. Huang
Tremendous efforts have been made in the last decade to advance cutting-edge MRI technology in pursuit of mapping structural connectivity in the living human brain with unprecedented sensitivity and speed. The first Connectom 3T MRI scanner equipped with a 300 mT/m whole-body gradient system was installed at the Massachusetts General Hospital in 2011 and was specifically constructed as part of the Human Connectome Project. Since that time, numerous technological advances have been made to enable the broader use of the Connectom high gradient system for diffusion tractography and tissue microstructure studies and leverage its unique advantages and sensitivity to resolving macroscopic and microscopic structural information in neural tissue for clinical and neuroscientific studies. The goal of this review article is to summarize the technical developments that have emerged in the last decade to support and promote large-scale and scientific studies of the human brain using the Connectom scanner. We provide a brief historical perspective on the development of Connectom gradient technology and the efforts that led to the installation of three other Connectom 3T MRI scanners worldwide – one in the United Kingdom in Cardiff, Wales, another in continental Europe in Leipzig, Germany, and the latest in Asia in Shanghai, China. We summarize the key developments in gradient hardware and image acquisition technology that have formed the backbone of Connectom-related research efforts, including the rich array of high-sensitivity receiver coils, pulse sequences, image artifact correction strategies and data preprocessing methods needed to optimize the quality of high-gradient strength diffusion MRI data for subsequent analyses. Finally, we review the scientific impact of the Connectom MRI scanner, including advances in diffusion tractography, tissue microstructural imaging, ex vivo validation, and clinical investigations that have been enabled by Connectom technology. We conclude with brief insights into the unique value of strong gradients for diffusion MRI and where the field is headed in the coming years.

17 June 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
MAMaryam Afzali
Maryam Afzali
LMLars Mueller
Lars Mueller
KSKen Sakaie
Ken Sakaie
SHSiyuan Hu
Siyuan Hu
YCYong Chen
Yong Chen
DMDan Ma
Dan Ma
Purpose: Although both relaxation and diffusion imaging are sensitive to tissue microstructure, studies have reported limited sensitivity and robustness of using relaxation or conventional diffusion alone to characterize tissue microstructure. Recently, it has been shown that tensor‐valued diffusion encoding and joint relaxation‐diffusion quantification enable more reliable quantification of compartment‐specific microstructural properties. However, scan times to acquire such data can be prohibitive. Here, we aim to simultaneously quantify relaxation and diffusion using MR fingerprinting (MRF) and b‐tensor encoding in a clinically feasible time.Methods: We developed multidimensional MRF scans (mdMRF) with linear and spherical b‐tensor encoding (LTE and STE) to simultaneously quantify T1, T2, and ADC maps from a single scan. The image quality, accuracy, and scan efficiency were compared between the mdMRF using LTE and STE. Moreover, we investigated the robustness of different sequence designs to signal errors and their impact on the maps.Results: T1 and T2 maps derived from the mdMRF scans have consistently high image quality, while ADC maps are sensitive to different sequence designs. Notably, the fast imaging steady state precession (FISP)‐based mdMRF scan with peripheral pulse gating provides the best ADC maps that are free of image distortion and shading artifacts.Conclusion: We demonstrated the feasibility of quantifying T1, T2, and ADC maps simultaneously from a single mdMRF scan in around 24 s/slice. The map quality and quantitative values are consistent with the reference scans.

1 August 2021 in NeuroImage
Verified
Journal Article
Open access
MAMaryam Afzali
Maryam Afzali
MNMarkus Nilsson
Markus Nilsson
MPMarco Palombo
Marco Palombo
DJDerek K Jones
Derek K Jones
The Soma and Neurite Density Imaging (SANDI) three-compartment model was recently proposed to disentangle cylindrical and spherical geometries, attributed to neurite and soma compartments, respectively, in brain tissue. There are some recent advances in diffusion-weighted MRI signal encoding and analysis (including the use of multiple so-called 'b-tensor' encodings and analysing the signal in the frequency-domain) that have not yet been applied in the context of SANDI. In this work, using: (i) ultra-strong gradients; (ii) a combination of linear, planar, and spherical b-tensor encodings; and (iii) analysing the signal in the frequency domain, three main challenges to robust estimation of sphere size were identified: First, the Rician noise floor in magnitude-reconstructed data biases estimates of sphere properties in a non-uniform fashion. It may cause overestimation or underestimation of the spherical compartment size and density. This can be partly ameliorated by accounting for the noise floor in the estimation routine. Second, even when using the strongest diffusion-encoding gradient strengths available for human MRI, there is an empirical lower bound on the spherical signal fraction and radius that can be detected and estimated robustly. For the experimental setup used here, the lower bound on the sphere signal fraction was approximately 10%. We employed two different ways of establishing the lower bound for spherical radius estimates in white matter. The first, examining power-law relationships between the DW-signal and diffusion weighting in empirical data, yielded a lower bound of 7μm, while the second, pure Monte Carlo simulations, yielded a lower limit of 3μm and in this low radii domain, there is little differentiation in signal attenuation. Third, if there is sensitivity to the transverse intra-cellular diffusivity in cylindrical structures, e.g., axons and cellular projections, then trying to disentangle two diffusion-time-dependencies using one experimental parameter (i.e., change in frequency-content of the encoding waveform) makes spherical radii estimates particularly challenging. We conclude that due to the aforementioned challenges spherical radii estimates may be biased when the corresponding sphere signal fraction is low, which must be considered.

22 April 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
MAMaryam Afzali
Maryam Afzali
LMLars Mueller
Lars Mueller
SCSam Coveney
Sam Coveney
Fabrizio FasanoFabrizio Fasano
Fabrizio Fasano
CEChristopher John Evans
Christopher John Evans
JSJürgen E. Schneider
Jürgen E. Schneider
Purpose: This work reports for the first time on the implementation and application of cardiac diffusion‐weighted MRI on a Connectom MR scanner with a maximum gradient strength of 300 mT/m. It evaluates the benefits of the increased gradient performance for the investigation of the myocardial microstructure.Methods: Cardiac diffusion‐weighted imaging (DWI) experiments were performed on 10 healthy volunteers using a spin‐echo sequence with up to second‐ and third‐order motion compensation ( and ) and , and 1000 (twice the commonly used on clinical scanners). Mean diffusivity (MD), fractional anisotropy (FA), helix angle (HA), and secondary eigenvector angle (E2A) were calculated for b = [100, 450] and b = [100, 1000] for both and .Results: The MD values with are slightly higher than with with for and for . A reduction in MD is observed by increasing the from 450 to 1000 ( for and for ). The difference between FA, E2A, and HA was not significant in different schemes ().Conclusion: This work demonstrates cardiac DWI in vivo with higher b‐value and higher order of motion compensated diffusion gradient waveforms than is commonly used. Increasing the motion compensation order from to and the maximum b‐value from 450 to 1000 affected the MD values but FA and the angular metrics (HA and E2A) remained unchanged. Our work paves the way for cardiac DWI on the next‐generation MR scanners with high‐performance gradient systems.

12 July 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MAMaryam Afzali
Maryam Afzali
HKHans Knutsson
Hans Knutsson
EÖEvren Özarslan
Evren Özarslan
DJDerek K. Jones
Derek K. Jones
Numerous applications in diffusion MRI involve computing the orientationally-averaged diffusion-weighted signal. Most approaches implicitly assume, for a given b-value, that the gradient sampling vectors are uniformly distributed on a sphere (or ‘shell’), computing the orientationally-averaged signal through simple arithmetic averaging. One challenge with this approach is that not all acquisition schemes have gradient sampling vectors distributed over perfect spheres. To ameliorate this challenge, alternative averaging methods include: weighted signal averaging; spherical harmonic representation of the signal in each shell; and using Mean Apparent Propagator MRI (MAP-MRI) to derive a three-dimensional signal representation and estimate its ‘isotropic part’. Here, these different methods are simulated and compared under different signal-to-noise (SNR) realizations. With sufficiently dense sampling points (61 orientations per shell), and isotropically-distributed sampling vectors, all averaging methods give comparable results, (MAP-MRI-based estimates give slightly higher accuracy, albeit with slightly elevated bias as b-value increases). As the SNR and number of data points per shell are reduced, MAP-MRI-based approaches give significantly higher accuracy compared with the other methods. We also apply these approaches to in vivo data where the results are broadly consistent with our simulations. A statistical analysis of the simulated data shows that the orientationally-averaged signals at each b-value are largely Gaussian distributed.