Dan Ma

Dan Ma

Auto-generated profile, based on publicly available information

Dan Ma

Department of Neurosurgery, Duke University

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
JHJesse I. Hamilton
Jesse I. Hamilton
YJYun Jiang
Yun Jiang
YCYong Chen
Yong Chen
DMDan Ma
Dan Ma
WLWei-Ching Lo
Wei-Ching Lo
NSNicole Seiberlich
Nicole Seiberlich

4 October 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
BZBo Zhao
Bo Zhao
JHJustin P. Haldar
Justin P. Haldar
CLCongyu Liao
Congyu Liao
DMDan Ma
Dan Ma
YJYun Jiang
Yun Jiang
LWLawrence L. Wald
Lawrence L. Wald
Magnetic resonance (MR) fingerprinting is a new quantitative imaging paradigm, which simultaneously acquires multiple MR tissue parameter maps in a single experiment. In this paper, we present an estimation-theoretic framework to perform experiment design for MR fingerprinting. Specifically, we describe a discrete-time dynamic system to model spin dynamics, and derive an estimation-theoretic bound, i.e., the Cramér-Rao bound (CRB), to characterize the signal-to-noise ratio (SNR) efficiency of an MR fingerprinting experiment. We then formulate an optimal experiment design problem, which determines a sequence of acquisition parameters to encode MR tissue parameters with the maximal SNR efficiency, while respecting the physical constraints and other constraints from the image decoding/reconstruction process. We evaluate the performance of the proposed approach with numerical simulations, phantom experiments, and in vivo experiments. We demonstrate that the optimized experiments substantially reduce data acquisition time and/or improve parameter estimation. For example, the optimized experiments achieve about a factor of two improvement in the accuracy of T2 maps, while keeping similar or slightly better accuracy of T1 maps. Finally, as a remarkable observation, we find that the sequence of optimized acquisition parameters appears to be highly structured rather than randomly/pseudo-randomly varying as is prescribed in the conventional MR fingerprinting experiments.

29 December 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
CBC. Badve
C. Badve
AYA. Yu
A. Yu
SDS. Dastmalchian
S. Dastmalchian
MRM. Rogers
M. Rogers
DMD. Ma
D. Ma
VGVikas Gulani
Vikas Gulani
BACKGROUND AND PURPOSE: MR fingerprinting allows rapid simultaneous quantification of T1 and T2 relaxation times. This study assessed the utility of MR fingerprinting in differentiating common types of adult intra-axial brain tumors. MATERIALS AND METHODS: MR fingerprinting acquisition was performed in 31 patients with untreated intra-axial brain tumors: 17 glioblastomas, 6 World Health Organization grade II lower grade gliomas, and 8 metastases. T1, T2 of the solid tumor, immediate peritumoral white matter, and contralateral white matter were summarized within each ROI. Statistical comparisons on mean, SD, skewness, and kurtosis were performed by using the univariate Wilcoxon rank sum test across various tumor types. Bonferroni correction was used to correct for multiple-comparison testing. Multivariable logistic regression analysis was performed for discrimination between glioblastomas and metastases, and area under the receiver operator curve was calculated. RESULTS: Mean T2 values could differentiate solid tumor regions of lower grade gliomas from metastases (mean, 172 ± 53 ms, and 105 ± 27 ms, respectively; P = .004, significant after Bonferroni correction). The mean T1 of peritumoral white matter surrounding lower grade gliomas differed from peritumoral white matter around glioblastomas (mean, 1066 ± 218 ms, and 1578 ± 331 ms, respectively; P = .004, significant after Bonferroni correction). Logistic regression analysis revealed that the mean T2 of solid tumor offered the best separation between glioblastomas and metastases with an area under the curve of 0.86 (95% CI, 0.69–1.00; P < .0001). CONCLUSIONS: MR fingerprinting allows rapid simultaneous T1 and T2 measurement in brain tumors and surrounding tissues. MR fingerprinting–based relaxometry can identify quantitative differences between solid tumor regions of lower grade gliomas and metastases and between peritumoral regions of glioblastomas and lower grade gliomas.

1 August 2019 in Radiology
Verified
Journal Article
Closed access
GKGregor Koerzdoerfer
Gregor Koerzdoerfer
RKRainer Kirsch
Rainer Kirsch
KLKecheng Liu
Kecheng Liu
JPJosef Pfeuffer
Josef Pfeuffer
BHBernhard Hensel
Bernhard Hensel
MNMathias Nittka
Mathias Nittka
Relaxation times in solid compartments of the human brain measured with fast imaging with steady-state free precession MR fingerprinting varied less than 8.0% (95% confidence intervals: −8.0%, 8.0%... Background Only sparse literature investigates the reproducibility and repeatability of relaxometry methods in MRI. However, statistical data on reproducibility and repeatability of any quantitativ...

23 December 2018 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
DMDan Ma
Dan Ma
SJStephen E. Jones
Stephen E. Jones
ADAnagha Deshmane
Anagha Deshmane
KSKen Sakaie
Ken Sakaie
EPEric Y. Pierre
Eric Y. Pierre
ZWZ. Irene Wang
Z. Irene Wang

1 November 2018 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
JHJesse I. Hamilton
Jesse I. Hamilton
YJYun Jiang
Yun Jiang
DMDan Ma
Dan Ma
WLWei-Ching Lo
Wei-Ching Lo
VGVikas Gulani
Vikas Gulani
NSNicole Seiberlich
Nicole Seiberlich