Jennifer L. Vanderbeck

Jennifer L. Vanderbeck

Auto-generated profile, based on publicly available information

Jennifer L. Vanderbeck

Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2025 in JSES International
Verified
Journal Article
Open access
GTGrayson M. Talaski
Grayson M. Talaski
SYShahabeddin Yazdanpanah
Shahabeddin Yazdanpanah
MSMatthew Smith
Matthew Smith
BCBenjamin P. Cassidy
Benjamin P. Cassidy
JSJames R. Satalich
James R. Satalich
JVJennifer L. Vanderbeck
Jennifer L. Vanderbeck
Olecranon fractures comprise ∼10% of upper extremity fractures, often managed with open reduction and internal fixation (ORIF). Despite generally favorable outcomes, short-term complications remain challenging and uncharacterized. This retrospective study aims to address this gap by evaluating short-term complications of olecranon ORIF using a large, nationwide database to determine complication rates and identify associated risk factors. The American College of Surgeons National Surgical Quality Improvement Program database (2010-2023) was queried for patients undergoing olecranon ORIF (Current Procedural Terminology Code 24685). Demographic, comorbidities, operative variables, and postoperative complications within 30 days were analyzed. Descriptive statistics and multivariate logistic regression were used to identify significant predictors (P < .05). A total of 8,524 patients (average age 59.4 ± 19.3; 62.3% female) were included. Surgical site infection was amongst the most common singular complications at a rate of 1.8%, with any adverse event reported at a rate of 7.2%. Risk factors included increased age (odds ratio [OR] = 1.03; P < .001), operative time (OR = 1.02; P < .001), blood transfusion (OR = 3.16; P = .001), ascites, and smoking history. Surgical site infection was associated with smoking (OR = 1.66; P = .01) and ascites (OR = 11.38; P = .03). ORIF for olecranon fractures demonstrates low short-term complication rates; however, specific comorbidities such as smoking and ascites were associated with increased risk. These findings highlight opportunities for improving care through providing smoking cessation efforts and tailored perioperative management for high-risk patients.

1 June 2025 in Clinics in Shoulder and Elbow
Verified
Journal Article
Open access
PDF file
SVSuhas Rao Velichala
Suhas Rao Velichala
BLBrigitte Lieu
Brigitte Lieu
ASAadi Sharma
Aadi Sharma
MSMatthew Smith
Matthew Smith
JSJames robert Satalich
James robert Satalich
JVJennifer Vanderbeck
Jennifer Vanderbeck
Background: Reverse shoulder arthroplasty (RSA) is an alternative to anatomic total shoulder arthroplasty (TSA) for treating glenohumeral osteoarthritis (OA), particularly in elderly patients. This study evaluates 90-day postoperative complication rates and identifies risk factors for adverse outcomes in RSA and TSA patients. Methods: A retrospective cohort study was conducted using the TriNetX Research NLP Network to identify patients aged 65–90 years who underwent RSA or TSA for OA from 2006 to 2024. 1:1 propensity score matching controlled for demographics and comorbidities. Orthopedic and infectious complications were compared using multivariate logistic regression. Results: The final matched cohort included 4,117 RSA and TSA patients. RSA was associated with significantly higher odds of orthopedic complications compared to TSA. Significant risk factors for orthopedic complications in RSA included nicotine dependence (OR, 1.592; P=0.001) and hypertension (OR, 1.545; P=0.001). In TSA, risk factors included male sex (OR, 0.702; P=0.005), chronic obstructive pulmonary disease (OR, 1.650; P=0.016), and obesity (OR, 1.776; P<0.001). For infections, RSA risk factors were male sex (odds ratio [OR], 1.698; P=0.005), heart failure (OR, 2.396; P<0.001), and diabetes (OR, 1.525; P=0.039). Diabetes was the only significant risk factor in TSA (OR, 2.453; P=0.003). Conclusions: RSA carries a higher risk of orthopedic complications and infection than TSA within 90 days. Distinct risk factors for each procedure highlight the need for patient-specific risk stratification to optimize preoperative assessment and surgical decision-making. Level of evidence: III.

22 July 2024 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Open access
PDF file
NKNicholas Reid Kiritsis
Nicholas Reid Kiritsis
Charles R ReiterCharles R Reiter
Charles R Reiter
JSJames robert Satalich
James robert Satalich
OPOmar Protzuk
Omar Protzuk
COConor O'Neill
Conor O'Neill
JVJennifer L. Vanderbeck
Jennifer L. Vanderbeck
Purpose: To determine the short-term complication rates following open reduction and internal fixation of scapula fractures, factors affecting the development of adverse events, and complication rates based on the anatomic location of the fracture. Methods: Thirty-day complication rates for patients who underwent open reduction and internal fixation of the scapula were compared between glenoid, body, coracoid, and acromion fracture locations, as identified by International Classification of Disease codes. Possible adverse events included postoperative surgical site infection, renal insufficiency, intubation, pneumonia, deep vein thrombosis, pulmonary embolism, urinary tract infection, wound dehiscence, stroke, and blood transfusion. Results: A total of 251 scapula fractures were identified, with 161 having known fracture locations: 105 glenoid, 20 body, 9 coracoid, and 27 acromial fractures. The rate of any adverse event for all scapular fractures was 2.0%, with no significant difference between anatomic locations (p = 0.79). The overall rates of transfusion, surgical site infection, and return to OR were 0.4%, 0.8%, and 3.98%. Steroid use associated with a significantly increased risk of any adverse event (OR: 55.57, p = 0.038) and outpatient status demonstrated a protective effect on reoperation (OR: 0.11, p = 0.014). There were no significant differences in the rates between groups [transfusion (p = 0.91); surgical site infection (p = 0.17); reoperation (p = 0.85)]. Conclusion: Complication rates within thirty days of ORIF for scapula fracture were low. Reoperation was the most common complication, followed by surgical site infection, wound dehiscence, stroke, transfusion, and pneumonia. Steroid use was a risk factor for developing any adverse event, and outpatient status was protective against reoperation. The 30-day complication profile of glenoid, body, coracoid, and acromial fractures was not significantly different. The low complication rates support the relative short-term safety of operative intervention with internal fixation. Level of Evidence: Level III.

1 January 2026 in JBJS Open Access
Verified
Journal Article
Open access
CPCasey J. Powell
Casey J. Powell
AHAnna Y. Huang
Anna Y. Huang
JCJohn Cyrus
John Cyrus
BCBenjamin P. Cassidy
Benjamin P. Cassidy
ACAndrew S. Cuthbert
Andrew S. Cuthbert
JVJennifer L. Vanderbeck
Jennifer L. Vanderbeck
Background: Orthopaedic personnel are routinely exposed to noise from saws, drills, and hammers that exceeds safety thresholds, placing them at significant risk of noise-induced hearing loss (NIHL). Despite this hazard, preventive measures remain infrequently used. This systematic review evaluates NIHL prevalence, intraoperative noise, and effectiveness of protective measures in operating rooms. Methods: Studies on the prevalence, risk, and prevention of NIHL in orthopaedic personnel published before July 21, 2025 were screened from PubMed/Medline, Ovid Embase, and CENTRAL (Cochrane). Thirty-four studies met the inclusion criteria. Results: NIHL was identified in 17% of participants, and 56 of 75 surgical instruments exceeded the National Institute for Occupational Safety and Health (NIOSH) A-weighted limits. Noise levels were consistently unsafe during total hip and knee arthroplasty, particularly when robotic-assisted. Custom hearing protection with interchangeable noise reduction filters reduced exposure while maintaining intraoperative communication, whereas surgical hood systems showed minimal benefit, and active noise-cancelling headphones had mixed results. Conclusions: Orthopaedic personnel are frequently exposed to noise levels exceeding safety thresholds, especially during robotic-assisted total knee arthroplasty, placing them at risk for NIHL. Evidence supports using custom hearing protection with communication-preserving filters, developing quieter surgical equipment, and implementing routine hearing assessments to improve long-term hearing outcomes. Level of Evidence: II.

1 September 2025 in JSES International
Verified
Journal Article
Open access
BGBraeden R. Gooch
Braeden R. Gooch
JTJosh W. Thibeault
Josh W. Thibeault
CRCharles R. Reiter
Charles R. Reiter
MSMatthew Smith
Matthew Smith
JSJoshua C. Setliff
Joshua C. Setliff
JVJennifer L. Vanderbeck
Jennifer L. Vanderbeck
The coracoclavicular (CC) ligament reconstruction for acromioclavicular injuries is performed through a variety of surgical techniques and fixation methods. The purpose of this study is to determine the risk factors associated with failure of CC reconstruction, regardless of the fixation method used. A systematic review was performed in compliance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Medline, Embase, and Cochrane were searched through November 2024 for studies analyzing the failures of CC reconstructive surgery. Studies that quantified risk factors for CC reconstruction failure were included. Seven studies comprising 781 CC reconstructions were analyzed with an overall failure rate of 19.1%. Clavicle tunnel malposition in anatomic reconstructions was the most cited risk factor for failure. Position was defined as either the distance from the lateral aspect of the clavicle to the tunnels or as a ratio between this distance and the length of the clavicle. Three studies cited increased failure risk with medial malposition of the conoid or trapezoid tunnels. Specific parameters included conoid tunnel ratio >0.25, (odds ratio (OR) = 5.67), trapezoid ratio >0.15 (OR = 4.2), conoid tunnel >47 mm (OR = 4.67), and trapezoid tunnel >24 mm (OR = 4.2). Lateral conoid tunnel malposition with a conoid tunnel ratio 6 weeks from initial injury (OR = 2.65), osteolysis (OR = 4.386), patient age >40 (OR = 3.14), and open reconstruction (OR = 4.25). Conoid and trapezoid tunnel malposition, both medially and laterally, were significantly associated with an increased risk of failure. Additionally, patient age, osteoporosis, osteolysis, time to weight bearing after surgery, delayed presentation of more than 6 weeks from initial injury, should be considered when considering surgical intervention.

5 May 2025 in Journal of Orthopaedics
Verified
Journal Article
Closed access
YSYasmin Alamdeen Shahzada
Yasmin Alamdeen Shahzada
MSMatthew Smith
Matthew Smith
PKPratiik Kaushik
Pratiik Kaushik
JSJosh Setliff
Josh Setliff
HHHaleigh Marie Hopper
Haleigh Marie Hopper
JVJennifer Vanderbeck
Jennifer Vanderbeck