Dong-Su Kim

Dong-Su Kim

Auto-generated profile, based on publicly available information

Dong-Su Kim

Energy & Nano Technology Group, Korea Institute of Industrial Technology (KITECH), Gwangju, Republic of Korea

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2019 in Journal of Materials Chemistry A
Verified
Journal Article
Closed access
PDF file
ASArunkumar Shanmugasundaram
Arunkumar Shanmugasundaram
NCNguyen Duc Chinh
Nguyen Duc Chinh
YJYun-Jin Jeong
Yun-Jin Jeong
THTian Feng Hou
Tian Feng Hou
DKDong-Su Kim
Dong-Su Kim
Dong-Weon LeeDong-Weon Lee
Dong-Weon Lee
A representative physical model depicting the H2S-sensing mechanism in air and H2S environments. Selectivity of the NiOBNG sensor to different interfering gases.

26 December 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
JPJongsung Park
Jongsung Park
DKDong-Su Kim
Dong-Su Kim
YYYoungsam Yoon
Youngsam Yoon
ASArunkumar Shanmugasundaram
Arunkumar Shanmugasundaram
Dong-Weon LeeDong-Weon Lee
Dong-Weon Lee
Over the years, several bare metal and crack-based strain sensors have been proposed for various fields of science and technology. However, due to their low gauge factor, metal-based strain sensors have limited practical applications. The crack-based strain sensor, on the other hand, demonstrated excellent sensitivity and a high gauge factor. However, the crack-based strain sensor exhibited non-linear behavior at low strains, severely limiting its real-time applications. Generally, the crack-based strain sensors are fabricated by generating cracks by bending a polymer film on which a metal layer has been deposited with a constant curvature. However, the random formation of cracks produces nonlinear behavior in the crack sensors. To overcome the limitations of the current state of the art, we propose a V-groove-based metal strain sensor for human motion monitoring and Morse code generation. The V-groove crack-based strain sensor is fabricated on polyurethane acrylate (PUA) using the modified photolithography technique. During the procedure, a V-groove pattern formed on the surface of the sensor, and a uniform crack formed over the entire surface by concentrating stress along the groove. To improve the sensitivity and selectivity of the sensor, we generated the cracks in a controlled direction. The proposed strain sensor exhibited high sensitivity and excellent fidelity compared to the other reported metal strain sensors. The gauge factor of the proposed V-groove-induced crack sensor is 10-fold higher than the gauge factor of the reported metal strain sensors. In addition, the fabricated V-groove-based strain sensor exhibited rapid response and recovery times. The practical feasibility of the proposed V-groove-induced crack-based strain sensor is demonstrated through human motion monitoring and the generation of Morse code. The proposed V-groove crack sensor can detect multiple motions in a variety of human activities and is anticipated to be utilized in several applications due to its high durability and reproducibility.

1 September 2006
Verified
Conference Paper
Closed access
DKDongsu Kim
Dongsu Kim
HCHyun Min Cho
Hyun Min Cho
NKNam Sook Kang
Nam Sook Kang
JPJong Chul Park
Jong Chul Park
JKJun Chul Kim
Jun Chul Kim
This paper presents LTCC front-end modules for multi-band applications. A dual-band module composed of a diplexer, a CDMA SAW duplexer, and a GPS SAW filter for CDMA/GPS applications and a tri-band module employing PIN diodes for CDMA/GPS/PCS applications are implemented based on LTCC substrates. The measured results of the dual-band module show that the insertion loss is less than 2.4 dB and 3.5 dB in CDMA Tx and Rx bands, respectively. The insertion of GPS path is about 1.8 dB. The tri-band module provides an insertion loss of less than 0.8 dB and 1.1 dB in CDMA and PCS bands, respectively. The insertion of GPS path is about 0.4 dB. The overall size of both modules is only 4.5 mm times 3.2 mm

13 January 2025 in Carbon Trends
Verified
Journal Article
Open access
THTae Won Ha
Tae Won Ha
CLChil-Hyoung Lee
Chil-Hyoung Lee
DLDae Yun Lim
Dae Yun Lim
YKYoung Baek Kim
Young Baek Kim
HCHyunjin Cho
Hyunjin Cho
DKDong-Su Kim
Dong-Su Kim

20 May 2025 in Electronic Materials Letters
Verified
Journal Article
Closed access
PDF file
DKDong-Su Kim
Dong-Su Kim
THTae Won Ha
Tae Won Ha
IPIn Jae Park
In Jae Park
DLDae Yun Lim
Dae Yun Lim
YKYoung Baek Kim
Young Baek Kim
CLchil-Hyoung Lee
chil-Hyoung Lee

4 December 2023 in The Analyst
Verified
Journal Article
Open access
PDF file
JKJongyun Kim
Jongyun Kim
ASArunkumar Shanmugasundaram
Arunkumar Shanmugasundaram
DKDong-Su Kim
Dong-Su Kim
YJYun-Jin Jeong
Yun-Jin Jeong
PKPooja P. Kanade
Pooja P. Kanade
Dong-Weon LeeDong-Weon Lee
Dong-Weon Lee
Correction for ‘Quantitative assessment of cardiomyocyte mechanobiology through high-throughput cantilever-based functional well plate systems’ by Jongyun Kim et al. , Analyst , 2023, 148 , 5133–5143, https://doi.org/10.1039/D3AN01286G.